  "schemaVersion": "1.0",
  "url": "https://www.mrwallcover.com/ai/fire-ratings.json",
  "sourceUrl": "https://www.mrwallcover.com/advice/wallcovering-fire-ratings-uk/",
  "markdownUrl": "https://www.mrwallcover.com/advice/wallcovering-fire-ratings-uk/index.md",
  "title": "Wallcovering Fire Ratings: British Standards and Commercial Specification",
  "description": "How reaction-to-fire classes such as B-s1,d0 are read, which standards and guidance apply in England, Wales, Scotland and Northern Ireland, and what makers' documents show for specific commercial wallcoverings.",
  "published": "2026-10-15",
  "updated": "2026-10-17",
  "checked": "2026-10-15",
  "sourceCheckDates": [
    "2026-10-15",
    "2026-10-17"
  ],
  "scope": {
    "jurisdiction": "England first (Approved Document B), with Wales, Scotland and Northern Ireland set out separately. It is not legal advice, and it does not cover any country outside the UK.",
    "sourcesChecked": "2026-10-15",
    "review": "Makers and regulators can change their documents at any time. Each product row shows the date we last read its documents; ask the maker for its current declaration before relying on a row.",
    "notice": "General specification guidance, not project-specific fire-safety approval. It has not been reviewed by a chartered fire engineer. Who confirms the class a wall or ceiling needs, and whether a proposed build-up achieves it, depends on the job: for building work, the designer or fire engineer with the building-control body. For redecorating a building in use that is not building work, the responsible person under fire-safety law confirms it, often with a fire risk assessor. Its main assessment and general fire-precaution duties do not apply inside a private home or, in Scotland and Northern Ireland, to the shared parts of a block of flats. A narrow duty to maintain facilities for firefighters still applies to those shared parts."
  },
  "decoder": {
    "introduction": "A European reaction-to-fire class has up to three parts: the main class (A1 to F), a smoke subclass (s1 to s3) and a flaming droplets subclass (d0 to d2). Read the notation exactly as the document prints it. For classes A2, B, C and D, a smoke or droplet subclass that is not printed is unknown, not assumed. Classes A1 and F carry no subclasses; class E carries no smoke subclass and is followed by d2 only if the filter paper ignited.",
    "classes": [
      {
        "code": "A1",
        "label": "highest",
        "meaning": "The highest class. The product passes both the non-combustibility and the calorific-value tests. No smoke or droplet subclass is given.",
        "basis": "BS EN ISO 1182 and BS EN ISO 1716.",
        "sourceIds": [
          "src-reg-2016-364-legis",
          "src-adb2-2026-consolidated"
        ]
      },
      {
        "code": "A2",
        "label": "",
        "meaning": "Passes one of the A1 tests to a less strict limit, and the single burning item test to the class B limits. Carries smoke and droplet subclasses.",
        "basis": "BS EN ISO 1182 or BS EN ISO 1716, plus BS EN 13823: fire growth rate (FIGRA) up to 120 W/s, lateral flame spread short of the specimen edge, total heat release in 600 s up to 7.5 MJ.",
        "sourceIds": [
          "src-reg-2016-364-legis",
          "src-adb2-2026-consolidated"
        ]
      },
      {
        "code": "B",
        "label": "",
        "meaning": "A limited contribution to fire growth in the single burning item test, and limited flame spread from a small flame.",
        "basis": "BS EN 13823: FIGRA up to 120 W/s, lateral flame spread short of the specimen edge, total heat release in 600 s up to 7.5 MJ. BS EN ISO 11925-2: 30-second flame, flame spread no more than 150 mm within 60 seconds.",
        "sourceIds": [
          "src-reg-2016-364-legis",
          "src-adb2-2026-consolidated"
        ]
      },
      {
        "code": "C",
        "label": "",
        "meaning": "As class B, with higher limits for fire growth and total heat release.",
        "basis": "BS EN 13823: FIGRA up to 250 W/s, lateral flame spread short of the specimen edge, total heat release in 600 s up to 15 MJ. BS EN ISO 11925-2: 30-second flame, flame spread no more than 150 mm within 60 seconds.",
        "sourceIds": [
          "src-reg-2016-364-legis",
          "src-adb2-2026-consolidated"
        ]
      },
      {
        "code": "D",
        "label": "",
        "meaning": "A higher fire-growth limit in the single burning item test and the same small-flame test as B and C.",
        "basis": "BS EN 13823: FIGRA up to 750 W/s. BS EN ISO 11925-2: 30-second flame, flame spread no more than 150 mm within 60 seconds.",
        "sourceIds": [
          "src-reg-2016-364-legis",
          "src-adb2-2026-consolidated"
        ]
      },
      {
        "code": "E",
        "label": "",
        "meaning": "Passes a shorter small-flame test only. May carry d2 if the filter paper ignites; no smoke subclass.",
        "basis": "BS EN ISO 11925-2: 15-second flame, flame spread no more than 150 mm within 20 seconds.",
        "sourceIds": [
          "src-reg-2016-364-legis",
          "src-adb2-2026-consolidated"
        ]
      },
      {
        "code": "F",
        "label": "lowest",
        "meaning": "Assigned when a product fails to attain class E. It is a class, not a blank: different from “no performance determined” and from an untested product.",
        "basis": "BS EN ISO 11925-2: 15-second flame, flame spread more than 150 mm within 20 seconds (Delegated Regulation 2016/364, Table 1); England's Approved Document B, Appendix B, paragraph B6.",
        "sourceIds": [
          "src-adb2-2026-consolidated",
          "src-reg-2016-364-legis"
        ]
      }
    ],
    "smoke": [
      {
        "code": "s1",
        "label": "lowest smoke",
        "meaning": "The lowest smoke production category in the single burning item test.",
        "basis": "Smoke growth rate (SMOGRA) up to 30 m²/s² and total smoke production in 600 s up to 50 m².",
        "sourceIds": [
          "src-reg-2016-364-legis",
          "src-adb2-2026-consolidated"
        ]
      },
      {
        "code": "s2",
        "label": "",
        "meaning": "More smoke allowed than s1, still within a limit.",
        "basis": "SMOGRA up to 180 m²/s² and total smoke production in 600 s up to 200 m².",
        "sourceIds": [
          "src-reg-2016-364-legis"
        ]
      },
      {
        "code": "s3",
        "label": "no limit set",
        "meaning": "Neither s1 nor s2: no limit is set for smoke production.",
        "basis": "Not s1 or s2. Approved Document B: s3 means no limit is set.",
        "sourceIds": [
          "src-reg-2016-364-legis",
          "src-adb2-2026-consolidated"
        ]
      }
    ],
    "droplets": [
      {
        "code": "d0",
        "label": "none",
        "meaning": "No flaming droplets or particles in the single burning item test within 600 seconds.",
        "basis": "BS EN 13823 observation over 600 s.",
        "sourceIds": [
          "src-reg-2016-364-legis",
          "src-adb2-2026-consolidated"
        ]
      },
      {
        "code": "d1",
        "label": "",
        "meaning": "No flaming droplets or particles that persist for longer than 10 seconds within 600 seconds.",
        "basis": "BS EN 13823 observation over 600 s.",
        "sourceIds": [
          "src-reg-2016-364-legis"
        ]
      },
      {
        "code": "d2",
        "label": "no limit set",
        "meaning": "Neither d0 nor d1: no limit is set for flaming droplets. Also given when the filter paper ignites in the small-flame test.",
        "basis": "Not d0 or d1; or paper ignition in BS EN ISO 11925-2.",
        "sourceIds": [
          "src-reg-2016-364-legis",
          "src-adb2-2026-consolidated"
        ]
      }
    ],
    "examples": [
      {
        "notation": "B-s1,d0",
        "reading": "Class B; s1, the lowest smoke category in the test; d0, no flaming droplets or particles.",
        "note": "It describes the tested build-up in the classification document, not the product on any wall."
      },
      {
        "notation": "B-s2,d0",
        "reading": "Class B; s2, more smoke allowed than s1 but within a limit; d0, no flaming droplets or particles.",
        "note": "The main class and the droplet result match B-s1,d0; only the smoke category differs."
      },
      {
        "notation": "C-s3,d2",
        "reading": "Class C with no limit set for smoke or droplets.",
        "note": "The class England's Table 6.1 gives for “other rooms”."
      },
      {
        "notation": "Euroclass B",
        "reading": "Main class B. The smoke and droplet subclasses are not stated, so they are unknown.",
        "note": "Ask for the declaration of performance or classification report, which will state them."
      },
      {
        "notation": "Class 0",
        "reading": "Not a European class. A British national classification based on BS 476 tests, no longer used in England's Approved Document B but still printed in the Welsh and Northern Irish guidance.",
        "note": "There is no automatic conversion to a European class; see below."
      }
    ]
  },
  "standards": [
    {
      "id": "std-13501-1",
      "designation": "BS EN 13501-1",
      "title": "Fire classification of construction products and building elements. Classification using data from reaction to fire tests",
      "latestEdition": "BS EN 13501-1:2018",
      "published": "January 2019",
      "status": "Current",
      "role": "Turns the results of the reaction-to-fire tests into a class (A1 to F) with smoke and droplet subclasses.",
      "editionNote": "Some older reports and declarations cite EN 13501-1:2007+A1:2009, which BSI shows as withdrawn in January 2019. A document citing the older edition is not automatically invalid; record the edition it cites and ask the maker if in doubt.",
      "sourceIds": [
        "src-bsi-13501-1-landing",
        "src-bsi-13501-1-kn"
      ]
    },
    {
      "id": "std-13823",
      "designation": "BS EN 13823",
      "title": "Reaction to fire tests for building products. Building products excluding floorings exposed to the thermal attack by a single burning item (SBI)",
      "latestEdition": "BS EN 13823:2020+A1:2022",
      "published": "January 2023",
      "status": "Current (BSI marks it under review)",
      "role": "The single burning item test: a corner test that measures heat release, lateral flame spread, smoke production and flaming droplets for classes A2 to D.",
      "editionNote": "BSI shows earlier editions current until these dates: 2002 to October 2010, 2010 to November 2014, 2010+A1:2014 to May 2020, and 2020 to January 2023. A report cites the edition used when the product was tested; record the edition it cites.",
      "sourceIds": [
        "src-bsi-13823-kn"
      ]
    },
    {
      "id": "std-11925-2",
      "designation": "BS EN ISO 11925-2",
      "title": "Reaction to fire tests. Ignitability of products subjected to direct impingement of flame. Single-flame source test",
      "latestEdition": "BS EN ISO 11925-2:2026",
      "published": "January 2026",
      "status": "Current",
      "role": "A small-flame ignitability test used for classes B to F; ignition of the filter paper below the specimen gives the d2 droplet subclass.",
      "editionNote": "The 2020 edition was current until January 2026, so almost every report you will see cites 2020 or 2010.",
      "sourceIds": [
        "src-bsi-11925-2-kn"
      ]
    },
    {
      "id": "std-1182-1716",
      "designation": "BS EN ISO 1182 and BS EN ISO 1716",
      "title": "Non-combustibility test; determination of the gross heat of combustion",
      "latestEdition": "BS EN ISO 1182:2020; BS EN ISO 1716:2018",
      "published": "2020; 2018",
      "status": "Current",
      "role": "Used only for classes A1 and A2. None of the wallcovering reports we read used them.",
      "editionNote": null,
      "sourceIds": [
        "src-bsi-1182-kn",
        "src-bsi-1716-kn"
      ]
    },
    {
      "id": "std-15102",
      "designation": "BS EN 15102",
      "title": "Decorative wallcoverings. Roll form (2019); previously Decorative wall coverings. Roll and panel form (2007+A1:2011)",
      "latestEdition": "BS EN 15102:2019",
      "published": "June 2019",
      "status": "Current at BSI; the 2007+A1:2011 edition is the one cited in the GB designated-standards list and the EU list",
      "role": "The product standard for decorative wallcoverings, under which makers declare reaction to fire. England's Table 6.1 note refers to wallcoverings that conform to it.",
      "editionNote": "The edition BSI treats as current (2019) is not the edition cited for UKCA and CE marking (2007+A1:2011), and Approved Document B also lists 2007+A1:2011. Declarations of performance normally cite 2007+A1:2011. Do not read one as the other.",
      "sourceIds": [
        "src-bsi-15102-2019-kn",
        "src-bsi-15102-2007-kn",
        "src-gov-ds-notice-0123-25",
        "src-ec-cpr-summary-2026"
      ]
    },
    {
      "id": "std-13238",
      "designation": "BS EN 13238",
      "title": "Reaction to fire tests for building products. Conditioning procedures and general rules for selection of substrates",
      "latestEdition": "BS EN 13238:2026",
      "published": "July 2026",
      "status": "Current (the 2010 edition was withdrawn in August 2026)",
      "role": "Sets the standard substrates products are tested on, which is why a classification names a substrate and holds only for substrates it represents.",
      "editionNote": "Approved Document B still lists the 2010 edition, and existing reports cite 2010.",
      "sourceIds": [
        "src-bsi-13238-kn",
        "src-adb2-2026-consolidated"
      ]
    },
    {
      "id": "std-15725",
      "designation": "BS EN 15725",
      "title": "Extended application on the fire performance of construction products and building elements",
      "latestEdition": "BS EN 15725:2023",
      "published": "March 2023",
      "status": "Current",
      "role": "Principles for extended-application reports, which assess whether a result can be extended beyond the tested build-up. England's guidance points to it.",
      "editionNote": "Approved Document B lists the 2010 edition.",
      "sourceIds": [
        "src-bsi-15725-kn"
      ]
    },
    {
      "id": "std-13501-2",
      "designation": "BS EN 13501-2",
      "title": "Fire classification of construction products and building elements. Classification using data from fire resistance and/or smoke control tests",
      "latestEdition": "BS EN 13501-2:2023",
      "published": "June 2023",
      "status": "Current (BSI marks it under review)",
      "role": "Fire resistance of building elements, in minutes (for example EI 30). Not a wallcovering standard; listed here to keep the two ideas apart.",
      "editionNote": null,
      "sourceIds": [
        "src-bsi-13501-2-kn"
      ]
    },
    {
      "id": "std-476-6-7",
      "designation": "BS 476-6 and BS 476-7",
      "title": "Fire tests on building materials and structures: fire propagation (Part 6); surface spread of flame (Part 7)",
      "latestEdition": "BS 476-6:1989+A1:2009; BS 476-7:1997",
      "published": "1989; 1997",
      "status": "Withdrawn by BSI on 4 March 2025",
      "role": "The British national tests, now withdrawn by BSI, behind Class 1 to 4 (Part 7) and the fire-propagation route to Class 0 (Parts 6 and 7); Class 0 could also be met by materials of limited combustibility.",
      "editionNote": "Removed from England's Approved Document B from 2 March 2025; still referred to in the Welsh and Northern Irish guidance.",
      "sourceIds": [
        "src-bsi-476-6-kn",
        "src-bsi-476-7-kn",
        "src-bsi-476-article"
      ]
    }
  ],
  "regulations": {
    "englandLinings": {
      "document": "Approved Document B, Volume 2 (buildings other than dwellings), 2019 edition incorporating the 2020, 2022, 2025 and 2026 amendments",
      "table": "England, Approved Document B Volume 2, Table 6.1",
      "notice": "Read the table, its notes and Section 6 in full before relying on it.",
      "rows": [
        {
          "location": "Small rooms",
          "detail": "Internal floor area of up to 4 m² in residential accommodation, or up to 30 m² in non-residential accommodation",
          "euroclass": "D-s3,d2"
        },
        {
          "location": "Other rooms",
          "detail": "Including garages",
          "euroclass": "C-s3,d2"
        },
        {
          "location": "Other circulation spaces",
          "detail": "See note 1 below for wallcoverings",
          "euroclass": "B-s3,d2"
        }
      ],
      "notes": [
        "Note 1 to the table (on the circulation-space row): wallcoverings conforming to BS EN 15102, achieving at least class C-s3,d2 and bonded to a class A2-s3,d2 substrate, are also acceptable.",
        "Paragraph 6.4: parts of walls in rooms may be of lower performance, but no worse than D-s3,d2, with the total lower-performance area less than half the room's floor area and no more than 20 m² (residential) or 60 m² (non-residential).",
        "Paragraphs 6.2 to 6.6 define what counts as a wall and a ceiling; paragraph 6.12 points to further guidance for escape stairs, firefighting shafts and surfaces above fire-protecting suspended ceilings.",
        "s3,d2 in the table means no limit is set for smoke production or flaming droplets (Appendix B, paragraph B7). A project may still specify a stricter subclass.",
        "This is guidance on one way of meeting requirement B2. The project's fire strategy, designer or building-control body may require more."
      ],
      "sourceIds": [
        "src-adb2-2026-consolidated"
      ]
    },
    "jurisdictions": [
      {
        "id": "england",
        "name": "England",
        "document": "Approved Document B, Volume 2 (Volume 1 covers dwellings, including blocks of flats and their common areas)",
        "edition": "2019 edition incorporating the 2020, 2022, 2025 and 2026 amendments, printed with the forthcoming 2029 changes",
        "linings": "Requirement B2; Section 6 and Table 6.1 give minimum European classes by location, with a BS EN 15102 note for wallcoverings in circulation spaces. Volume 1, Table 4.1, sets the same B-s3,d2, with the same note, for the common areas of blocks of flats.",
        "nationalClasses": "National reaction-to-fire classes (BS 476 Parts 6, 7 and 11) removed from the guidance from 2 March 2025, subject to transitional arrangements. National fire-resistance classes are due to be removed from 2 September 2029.",
        "dates": [
          {
            "label": "2025 amendments in force: national reaction-to-fire classes removed (transitional arrangements apply)",
            "date": "2025-03-02",
            "kind": "effective"
          },
          {
            "label": "2026 amendments in force: stairs and evacuation lifts in blocks of flats; no change to lining classes",
            "date": "2026-09-30",
            "kind": "effective"
          },
          {
            "label": "2029 amendments due: national fire-resistance classes removed",
            "date": "2029-09-02",
            "kind": "forthcoming"
          }
        ],
        "notes": [],
        "sourceIds": [
          "src-adb2-2026-consolidated",
          "src-adb1-2026-consolidated",
          "src-adb-2025-amendments",
          "src-adb-2026-amendments",
          "src-adb-2029-amendments"
        ]
      },
      {
        "id": "wales",
        "name": "Wales",
        "document": "Approved Document B, Volume 2 (Welsh edition), with Volume 1 for dwellinghouses",
        "edition": "Volume 2: 2006 edition incorporating the 2010, 2013, 2016, 2017 and 2020 amendments. Volume 1: 2006 edition incorporating the 2010, 2016 and 2020 amendments. Both are for use in Wales. An amendment slip in force from 20 December 2025 replaces the external-wall guidance and adds fire-service provisions for blocks of flats (wayfinding signage, evacuation alert systems, secure information boxes). It does not change Volume 2's Section 7 or Table 10.",
        "linings": "Requirement B2; Section 7 and Table 10 give both a national class and a European class for small rooms, other rooms, circulation spaces within dwellings, and other circulation spaces including the common areas of blocks of flats (Welsh Volume 2 covers flats). Note 5, on the circulation-space row, accepts BS EN 15102:2007 wallcoverings of at least C-s3,d2 bonded to an A2-s3,d2 substrate.",
        "nationalClasses": "Kept: Table 10 still lists national classes 3, 1 and 0 beside the European classes, and Appendix A still defines Class 0. The Welsh Government has said national classes will move to an appendix at the next revision; no date has been set.",
        "dates": [
          {
            "label": "2020 amendments in force (Welsh edition)",
            "date": "2020-12-31",
            "kind": "effective"
          },
          {
            "label": "Welsh Government consultation response: national classes to move to an appendix, not yet done",
            "date": "2025-01-08",
            "kind": "published"
          },
          {
            "label": "Amendment slip in force: external walls and fire-service provisions for blocks of flats; Table 10 unchanged",
            "date": "2025-12-20",
            "kind": "effective"
          },
          {
            "label": "Dutyholder and competence duties for building work, and the higher-risk building procedure, in force in Wales; lining classes unchanged",
            "date": "2026-07-01",
            "kind": "effective"
          }
        ],
        "notes": [
          "Wales did not adopt England's 2019 edition or its 2025 removal of national reaction-to-fire classes."
        ],
        "sourceIds": [
          "src-wales-adb-page",
          "src-wales-adb-vol2",
          "src-wales-slip-2025",
          "src-wales-wgc-004-2025",
          "src-wales-partb-summary",
          "src-wales-adb-vol1",
          "src-leg-wsi-2025-1320",
          "src-leg-wsi-2025-1321",
          "src-leg-wsi-2023-1210"
        ]
      },
      {
        "id": "scotland",
        "name": "Scotland",
        "document": "Building standards technical handbooks: non-domestic (linings table below) and domestic",
        "edition": "April 2026 handbooks (both published 9 March 2026), for building warrants submitted on or after 6 April 2026 and for building work that needs no warrant started on or after that date",
        "linings": "Non-domestic handbook: Standard 2.5 and Table 2.4 give European classes by building group (residential care buildings and hospitals, shops, all other buildings) and by location (rooms up to and over 30 m², unprotected zones, and protected zones and fire-fighting shafts). Domestic handbook: protected zones A1, A2 or B; rooms, unprotected zones and protected enclosures no worse than C; small rooms and limited wall areas D (clause 2.5.1). In both, clause 2.5.1 defines wall and ceiling surfaces as the substrate or lining material, excluding decorative wallpaper and paints, and says multiple layers can increase flame spread and are not recommended when redecorating.",
        "nationalClasses": "Not used for linings: reaction-to-fire classification uses European classes only (Annex 2.E, Table 2.20). The non-domestic handbook still accepts national BS 476 tests for fire resistance (Annex 2.D, clause 2.D.4, BS 476 Parts 20 to 24) and for roof coverings (Annex 2.F, BS 476-3). Where the non-domestic handbook gives a lining class without subclasses, s3,d2 is deemed included (Annex 2.E).",
        "dates": [
          {
            "label": "April 2026 handbooks apply (by building warrant date, or start date for work that needs no warrant)",
            "date": "2026-04-06",
            "kind": "effective"
          }
        ],
        "notes": [
          "Clause 2.5.1 of both handbooks excludes decorative wallpaper and paints from the classified surface but does not define them. Where the work needs a building warrant, agree with the verifier whether a given wallcovering is treated as decoration or as lining. Work that needs no warrant must still meet the building regulations, and the owner or client has the duty to comply. Both warn that multiple decorative layers can increase flame spread."
        ],
        "sourceIds": [
          "src-scot-collection",
          "src-scot-nd-apr2026-page",
          "src-scot-dom-apr2026-page",
          "src-scot-nd-2022-html",
          "src-leg-bsr-scotland-2004",
          "src-leg-bsr-scotland-2004-r5",
          "src-leg-bsr-scotland-2004-sch3"
        ]
      },
      {
        "id": "northern-ireland",
        "name": "Northern Ireland",
        "document": "Technical Booklet E: Fire safety",
        "edition": "October 2012 booklet as amended by AMD 7 (1 April 2022) and AMD 9 (6 May 2025)",
        "linings": "Regulation 34; Section 3 and Table 3.1 give both national and European classes by purpose group, room size and circulation space. There is no BS EN 15102 wallcovering note.",
        "nationalClasses": "Kept: Table 3.1 lists national classes (3, 1 and 0) beside European classes, and the booklet still defines Class 0 by reference to BS 476.",
        "dates": [
          {
            "label": "Technical Booklet E in effect",
            "date": "2012-10-31",
            "kind": "effective"
          },
          {
            "label": "AMD 7 in force (no change to Table 3.1 found)",
            "date": "2022-04-01",
            "kind": "effective"
          },
          {
            "label": "AMD 9 in force (no change to Table 3.1 found)",
            "date": "2025-05-06",
            "kind": "effective"
          }
        ],
        "notes": [
          "The Department publishes a track-changes version and says it is not an up-to-date consolidated version."
        ],
        "sourceIds": [
          "src-ni-tbe-page",
          "src-ni-tbe-2012",
          "src-ni-tbe-trackchanges",
          "src-ni-amd7",
          "src-ni-amd9",
          "src-leg-br-ni-2012-r2",
          "src-leg-br-ni-2012-r34"
        ]
      }
    ]
  },
  "productEvidenceNotice": "Each row covers only the product and build-up named. It is not a ranking and not a list of approved products.",
  "products": [
    {
      "id": "muraspec-fbv-type-ii-460",
      "sourceUrl": "https://www.mrwallcover.com/advice/wallcovering-fire-ratings-uk/#product-muraspec-fbv-type-ii-460",
      "manufacturer": "Muraspec",
      "product": "Fabric-backed vinyl, Type II, 460 gsm (woven and non-woven backings)",
      "reference": "Declaration of performance CPR0003, version 4 (July 2025)",
      "scope": "The two 460 gsm Type II product types listed in the declaration. No product codes or colourways are listed; Muraspec says the product code is on the packaging.",
      "construction": "Vinyl on woven or non-woven fabric backing, Type II",
      "weight": "460 gsm",
      "classificationRaw": "B-s2, d0 on fibre cement board attached with Murabond heavy adhesive",
      "notation": "B-s2, d0",
      "classification": {
        "class": "B",
        "smoke": "s2",
        "droplets": "d0"
      },
      "reading": "B-s2,d0",
      "classificationStandardCited": "EN 13501-1 (edition not printed)",
      "evidence": [
        {
          "sourceId": "src-muraspec-dop-0493-cpr0003-2025",
          "evidenceType": "declaration_of_performance",
          "label": "Declaration of performance",
          "documentReference": "CPR0003, V4 July 2025",
          "testBody": "Centexbel (notified body 0493)"
        },
        {
          "sourceId": "src-muraspec-dop-cpr0002-2024",
          "evidenceType": "declaration_of_performance",
          "label": "Declaration of performance",
          "documentReference": "CPR0002, V3 September 2024",
          "testBody": null
        },
        {
          "sourceId": "src-muraspec-hanging-leaflet-2026-05",
          "evidenceType": "technical_sheet",
          "label": "Technical data sheet",
          "documentReference": "Hanging information leaflet, May 2026",
          "testBody": null
        }
      ],
      "testedBuildup": {
        "substrate": "Fibre-cement board",
        "adhesive": "Murabond Heavy adhesive",
        "other": "No primer, lining, air gap or fixing is stated."
      },
      "fieldOfApplication": null,
      "limitations": [
        "The class is declared only for the fibre-cement and Murabond Heavy build-up.",
        "The declaration lists a notified-body certificate of conformity for each of these two product types (0493-CPR-W051, woven; 0493-CPR-W052, non-woven), with printed expiry dates of 28 October 2027 and 25 November 2027.",
        "Muraspec's May 2026 hanging leaflet (p. 1) requires Murabond Sealed Surface adhesive on non-absorbent walls and a coat of Murabond Primer on absorbent walls (diluted 1:3 on uncoated plaster, plasterboard and MDF; 1:1 on emulsion-painted walls). Neither is part of the declared fibre-cement and Murabond Heavy build-up."
      ],
      "gaps": [
        {
          "kind": "no-field-of-application",
          "text": "No field of application (permitted variations) is stated in the document we read."
        },
        {
          "kind": "conflict",
          "text": "Muraspec's earlier declaration CPR0002 (September 2024) declares B-s1,d0 for Type II non-woven fabric-backed vinyl; this 2025 declaration gives B-s2,d0."
        },
        {
          "kind": "unresolved",
          "text": "The classification report behind the declaration is not published."
        },
        {
          "kind": "unresolved",
          "text": "Muraspec has published two documents under the number CPR0003 (version 1, September 2024, BTTG; version 4, July 2025, Centexbel) with different scopes, and whether version 4 replaces version 1 is not stated."
        }
      ],
      "conflicts": [
        "Muraspec's earlier declaration CPR0002 (September 2024) declares B-s1,d0 for Type II non-woven fabric-backed vinyl; this 2025 declaration gives B-s2,d0."
      ],
      "unresolved": [
        "The classification report behind the declaration is not published.",
        "Muraspec has published two documents under the number CPR0003 (version 1, September 2024, BTTG; version 4, July 2025, Centexbel) with different scopes, and whether version 4 replaces version 1 is not stated."
      ],
      "status": "current",
      "evidenceLevel": "declaration_of_performance",
      "checked": "2026-10-15"
    },
    {
      "id": "muraspec-fbv-woven-type-i-360",
      "sourceUrl": "https://www.mrwallcover.com/advice/wallcovering-fire-ratings-uk/#product-muraspec-fbv-woven-type-i-360",
      "manufacturer": "Muraspec",
      "product": "Fabric-backed vinyl, woven Type I, 360 gsm",
      "reference": "Declaration of performance CPR0004, version 1 (September 2024)",
      "scope": "One product type at 360 gsm. The product code is on the packaging; no colourways are listed.",
      "construction": "Vinyl on woven fabric backing, Type I",
      "weight": "360 gsm",
      "classificationRaw": "Class B, s1, d0 (on fibre cement board using Murabond heavy adhesive) (CPR0004); overlapping CPR0001: B-s2, d0 (on fibre cement board using murabond heavy adhesive)",
      "notation": null,
      "classification": {
        "class": null,
        "smoke": null,
        "droplets": null
      },
      "reading": "not resolved: the documents disagree (see gaps)",
      "classificationStandardCited": "EN 13501-1:2018",
      "evidence": [
        {
          "sourceId": "src-muraspec-dop-cpr0004-2024-bttg",
          "evidenceType": "declaration_of_performance",
          "label": "Declaration of performance",
          "documentReference": "CPR0004, V1 September 2024",
          "testBody": "BTTG (printed with spelling errors and two addresses)"
        },
        {
          "sourceId": "src-muraspec-dop-cpr0001-2024",
          "evidenceType": "declaration_of_performance",
          "label": "Declaration of performance",
          "documentReference": "CPR0001, V3 September 2024",
          "testBody": "Elements Materials Technology Rotterdam BV (notified body 2812)"
        },
        {
          "sourceId": "src-muraspec-web-product-13602",
          "evidenceType": "webpage",
          "label": "Maker’s web page",
          "documentReference": "Product page 13602 (Frequency)",
          "testBody": null
        },
        {
          "sourceId": "src-muraspec-hanging-leaflet-2026-05",
          "evidenceType": "technical_sheet",
          "label": "Technical data sheet",
          "documentReference": "Hanging information leaflet, May 2026",
          "testBody": null
        }
      ],
      "testedBuildup": {
        "substrate": "Fibre-cement board",
        "adhesive": "Murabond Heavy adhesive",
        "other": "No primer, lining, air gap or fixing is stated."
      },
      "fieldOfApplication": null,
      "limitations": [
        "The class is declared only for the fibre-cement and Murabond Heavy build-up.",
        "Only 360 gsm is named.",
        "Muraspec's May 2026 hanging leaflet (p. 1) requires Murabond Sealed Surface adhesive on non-absorbent walls and a coat of Murabond Primer on absorbent walls (diluted 1:3 on uncoated plaster, plasterboard and MDF; 1:1 on emulsion-painted walls). Neither is part of the declared fibre-cement and Murabond Heavy build-up."
      ],
      "gaps": [
        {
          "kind": "no-field-of-application",
          "text": "No field of application (permitted variations) is stated in the document we read."
        },
        {
          "kind": "unclear-status",
          "text": "Ask the maker to confirm this document is still current before you rely on it."
        },
        {
          "kind": "conflict",
          "text": "Another Muraspec declaration signed the same day (CPR0001, version 3, 4 September 2024) declares B-s2,d0 for woven fabric-backed vinyl of 360 to 460 gsm, which overlaps this product; the two give different smoke subclasses and neither says it replaces the other."
        },
        {
          "kind": "conflict",
          "text": "Muraspec's product page for Frequency 13602 cites CPR0004 and gives a weight of 460 gsm, while the declaration names only 360 gsm."
        },
        {
          "kind": "unresolved",
          "text": "Which of the two woven declarations applies to a given roll is not explained."
        },
        {
          "kind": "unresolved",
          "text": "The laboratory report named in the declaration is not published."
        }
      ],
      "conflicts": [
        "Another Muraspec declaration signed the same day (CPR0001, version 3, 4 September 2024) declares B-s2,d0 for woven fabric-backed vinyl of 360 to 460 gsm, which overlaps this product; the two give different smoke subclasses and neither says it replaces the other.",
        "Muraspec's product page for Frequency 13602 cites CPR0004 and gives a weight of 460 gsm, while the declaration names only 360 gsm."
      ],
      "unresolved": [
        "Which of the two woven declarations applies to a given roll is not explained.",
        "The laboratory report named in the declaration is not published."
      ],
      "status": "unclear",
      "evidenceLevel": "declaration_of_performance",
      "checked": "2026-10-15"
    },
    {
      "id": "muraspec-digital-print-fbv-300-350",
      "sourceUrl": "https://www.mrwallcover.com/advice/wallcovering-fire-ratings-uk/#product-muraspec-digital-print-fbv-300-350",
      "manufacturer": "Muraspec",
      "product": "Digitally printed fabric-backed vinyl on non-woven, 300 gsm and 350 gsm bases (Digi Print 1.1 and 2.1)",
      "reference": "Declaration of performance CPR0003, version 1 (September 2024)",
      "scope": "Two digitally printed base types, each with its own laboratory report number. The declaration says nothing about print coverage, inks or bespoke artwork.",
      "construction": "Digitally printed vinyl on non-woven fabric backing",
      "weight": "300 gsm; 350 gsm",
      "classificationRaw": "Class B, s2, d0 (on fibre cement board using Murabond heavy adhesive)",
      "notation": "Class B, s2, d0",
      "classification": {
        "class": "B",
        "smoke": "s2",
        "droplets": "d0"
      },
      "reading": "B-s2,d0",
      "classificationStandardCited": "EN 13501-1:2018",
      "evidence": [
        {
          "sourceId": "src-muraspec-dop-cpr0003-2024-bttg",
          "evidenceType": "declaration_of_performance",
          "label": "Declaration of performance",
          "documentReference": "CPR0003, V1 September 2024",
          "testBody": "BTTG"
        },
        {
          "sourceId": "src-muraspec-dop-0493-cpr0003-2025",
          "evidenceType": "declaration_of_performance",
          "label": "Declaration of performance",
          "documentReference": "CPR0003, V4 July 2025",
          "testBody": "Centexbel (notified body 0493)"
        },
        {
          "sourceId": "src-muraspec-hanging-leaflet-2026-05",
          "evidenceType": "technical_sheet",
          "label": "Technical data sheet",
          "documentReference": "Hanging information leaflet, May 2026",
          "testBody": null
        }
      ],
      "testedBuildup": {
        "substrate": "Fibre-cement board",
        "adhesive": "Murabond Heavy adhesive",
        "other": "No primer, lining, air gap or fixing is stated."
      },
      "fieldOfApplication": null,
      "limitations": [
        "The class is declared only for the fibre-cement and Murabond Heavy build-up.",
        "Only the two named base weights are covered.",
        "Muraspec's 2025 declaration (CPR0003, version 4) lists certificate 0493-CPR-W048 for non-woven Type I, including digital products, with a printed expiry date of 18 October 2027.",
        "Muraspec's May 2026 hanging leaflet (p. 1) requires Murabond Sealed Surface adhesive on non-absorbent walls and a coat of Murabond Primer on absorbent walls (diluted 1:3 on uncoated plaster, plasterboard and MDF; 1:1 on emulsion-painted walls). Neither is part of the declared fibre-cement and Murabond Heavy build-up."
      ],
      "gaps": [
        {
          "kind": "no-field-of-application",
          "text": "No field of application (permitted variations) is stated in the document we read."
        },
        {
          "kind": "unclear-status",
          "text": "Ask the maker to confirm this document is still current before you rely on it."
        },
        {
          "kind": "conflict",
          "text": "Muraspec's July 2025 document carries the same number (CPR0003, version 4) with a wider scope and a different notified body (Centexbel 0493 instead of BTTG); whether it replaces this version 1 is not stated."
        },
        {
          "kind": "unresolved",
          "text": "Muraspec's 2025 declaration CPR0003 (version 4) also lists non-woven Type I fabric-backed vinyl of 270–460 gsm 'including Digital Products' at B-s2,d0; which of the two declarations applies to a given digital product is not stated."
        },
        {
          "kind": "unresolved",
          "text": "How print coverage, ink or bespoke artwork affects the classification is not stated."
        }
      ],
      "conflicts": [
        "Muraspec's July 2025 document carries the same number (CPR0003, version 4) with a wider scope and a different notified body (Centexbel 0493 instead of BTTG); whether it replaces this version 1 is not stated."
      ],
      "unresolved": [
        "Muraspec's 2025 declaration CPR0003 (version 4) also lists non-woven Type I fabric-backed vinyl of 270–460 gsm 'including Digital Products' at B-s2,d0; which of the two declarations applies to a given digital product is not stated.",
        "How print coverage, ink or bespoke artwork affects the classification is not stated."
      ],
      "status": "unclear",
      "evidenceLevel": "declaration_of_performance",
      "checked": "2026-10-15"
    },
    {
      "id": "muraspec-nonwoven-non-pvc-200",
      "sourceUrl": "https://www.mrwallcover.com/advice/wallcovering-fire-ratings-uk/#product-muraspec-nonwoven-non-pvc-200",
      "manufacturer": "Muraspec",
      "product": "Rotary-screen printed non-woven, non-PVC, 200 gsm",
      "reference": "Declaration of performance CPR0005, version 1 (September 2024)",
      "scope": "One product type at 200 gsm. The product code is on the packaging.",
      "construction": "Printed non-woven, PVC-free",
      "weight": "200 gsm",
      "classificationRaw": "Class B, s1, d0 (on fibre cement board using Murabond heavy adhesive)",
      "notation": "Class B, s1, d0",
      "classification": {
        "class": "B",
        "smoke": "s1",
        "droplets": "d0"
      },
      "reading": "B-s1,d0",
      "classificationStandardCited": "EN 13501-1:2018",
      "evidence": [
        {
          "sourceId": "src-muraspec-dop-cpr0005-2024-bttg",
          "evidenceType": "declaration_of_performance",
          "label": "Declaration of performance",
          "documentReference": "CPR0005, V1 September 2024",
          "testBody": "BTTG"
        },
        {
          "sourceId": "src-muraspec-hanging-leaflet-2026-05",
          "evidenceType": "technical_sheet",
          "label": "Technical data sheet",
          "documentReference": "Hanging information leaflet, May 2026",
          "testBody": null
        }
      ],
      "testedBuildup": {
        "substrate": "Fibre-cement board",
        "adhesive": "Murabond Heavy adhesive",
        "other": "No primer, lining, air gap or fixing is stated."
      },
      "fieldOfApplication": null,
      "limitations": [
        "The class is declared only for the fibre-cement and Murabond Heavy build-up.",
        "Muraspec's May 2026 hanging leaflet gives a different adhesive (Sealed Surface) for non-absorbent walls, which is outside the declared build-up."
      ],
      "gaps": [
        {
          "kind": "no-field-of-application",
          "text": "No field of application (permitted variations) is stated in the document we read."
        },
        {
          "kind": "unresolved",
          "text": "The laboratory report named in the declaration appears older than the declaration and is not published."
        }
      ],
      "conflicts": [],
      "unresolved": [
        "The laboratory report named in the declaration appears older than the declaration and is not published."
      ],
      "status": "current",
      "evidenceLevel": "declaration_of_performance",
      "checked": "2026-10-15"
    },
    {
      "id": "muraspec-pbv-220-300",
      "sourceUrl": "https://www.mrwallcover.com/advice/wallcovering-fire-ratings-uk/#product-muraspec-pbv-220-300",
      "manufacturer": "Muraspec",
      "product": "Paper-backed vinyl, 220 to 300 gsm",
      "reference": "Declaration of performance CPR0003, version 4 (July 2025)",
      "scope": "One product type covering 220 to 300 gsm. No product codes are listed.",
      "construction": "Vinyl on paper backing",
      "weight": "220–300 gsm",
      "classificationRaw": "B-s2, d0 on fibre cement board attached with Murabond heavy adhesive",
      "notation": "B-s2, d0",
      "classification": {
        "class": "B",
        "smoke": "s2",
        "droplets": "d0"
      },
      "reading": "B-s2,d0",
      "classificationStandardCited": "EN 13501-1 (edition not printed)",
      "evidence": [
        {
          "sourceId": "src-muraspec-dop-0493-cpr0003-2025",
          "evidenceType": "declaration_of_performance",
          "label": "Declaration of performance",
          "documentReference": "CPR0003, V4 July 2025",
          "testBody": "Centexbel (notified body 0493)"
        },
        {
          "sourceId": "src-muraspec-dop-cpr0002-2024",
          "evidenceType": "declaration_of_performance",
          "label": "Declaration of performance",
          "documentReference": "CPR0002, V3 September 2024",
          "testBody": null
        },
        {
          "sourceId": "src-muraspec-hanging-leaflet-2026-05",
          "evidenceType": "technical_sheet",
          "label": "Technical data sheet",
          "documentReference": "Hanging information leaflet, May 2026",
          "testBody": null
        }
      ],
      "testedBuildup": {
        "substrate": "Fibre-cement board",
        "adhesive": "Murabond Heavy adhesive",
        "other": "No primer, lining, air gap or fixing is stated."
      },
      "fieldOfApplication": null,
      "limitations": [
        "The class is declared only for the fibre-cement and Murabond Heavy build-up.",
        "Muraspec's hanging leaflet names a Light adhesive for some paper-backed ranges on absorbent walls; the declaration names only the Heavy adhesive.",
        "The declaration lists a notified-body certificate of conformity, 0493-CPR-W054, with a printed expiry date of 16 January 2028.",
        "Muraspec's May 2026 hanging leaflet (p. 1) requires Murabond Sealed Surface adhesive on non-absorbent walls and a coat of Murabond Primer on absorbent walls (diluted 1:3 on uncoated plaster, plasterboard and MDF; 1:1 on emulsion-painted walls). Neither is part of the declared fibre-cement and Murabond Heavy build-up."
      ],
      "gaps": [
        {
          "kind": "no-field-of-application",
          "text": "No field of application (permitted variations) is stated in the document we read."
        },
        {
          "kind": "conflict",
          "text": "An earlier declaration (CPR0002, version 3, September 2024) declares B-s1,d0 for paper-backed vinyl (no weight range given); this 2025 declaration gives B-s2,d0 for paper-backed vinyl of 220–300 gsm."
        },
        {
          "kind": "unresolved",
          "text": "Whether the 2024 declaration has been withdrawn or still applies to some production is not stated."
        },
        {
          "kind": "unresolved",
          "text": "The classification report is not published."
        }
      ],
      "conflicts": [
        "An earlier declaration (CPR0002, version 3, September 2024) declares B-s1,d0 for paper-backed vinyl (no weight range given); this 2025 declaration gives B-s2,d0 for paper-backed vinyl of 220–300 gsm."
      ],
      "unresolved": [
        "Whether the 2024 declaration has been withdrawn or still applies to some production is not stated.",
        "The classification report is not published."
      ],
      "status": "current",
      "evidenceLevel": "declaration_of_performance",
      "checked": "2026-10-15"
    },
    {
      "id": "muraspec-acoustic-foam-vinyl",
      "sourceUrl": "https://www.mrwallcover.com/advice/wallcovering-fire-ratings-uk/#product-muraspec-acoustic-foam-vinyl",
      "manufacturer": "Muraspec",
      "product": "Buflon Mousse Anafi acoustic foam vinyl (BM-61527103)",
      "reference": "Product web page",
      "scope": "The one product page, which lists 20 colourways.",
      "construction": "Foam vinyl on polyester non-woven backing (acoustic)",
      "weight": "580 gsm",
      "classificationRaw": "Euroclass C S3 D0 certification",
      "notation": "C S3 D0",
      "classification": {
        "class": "C",
        "smoke": "s3",
        "droplets": "d0"
      },
      "reading": "C-s3,d0",
      "classificationStandardCited": null,
      "evidence": [
        {
          "sourceId": "src-muraspec-web-product-bm-61527103",
          "evidenceType": "webpage",
          "label": "Maker’s web page",
          "documentReference": "Product page BM-61527103",
          "testBody": null
        },
        {
          "sourceId": "src-muraspec-web-explainer",
          "evidenceType": "webpage",
          "label": "Maker’s web page",
          "documentReference": "How do fire ratings work?",
          "testBody": null
        },
        {
          "sourceId": "src-muraspec-dop-cpr0001-2021",
          "evidenceType": "declaration_of_performance",
          "label": "Declaration of performance",
          "documentReference": "CPR0001, January 2021",
          "testBody": null
        },
        {
          "sourceId": "src-muraspec-dop-cpr0001-2024",
          "evidenceType": "declaration_of_performance",
          "label": "Declaration of performance",
          "documentReference": "CPR0001, V3 September 2024",
          "testBody": "Elements Materials Technology Rotterdam BV (notified body 2812)"
        }
      ],
      "testedBuildup": {
        "substrate": null,
        "adhesive": null,
        "other": null
      },
      "fieldOfApplication": null,
      "limitations": [
        "A web page statement only, not a declaration of performance or classification report.",
        "A class C product: it would not meet a class B requirement."
      ],
      "gaps": [
        {
          "kind": "no-buildup",
          "text": "The document we read does not name the tested substrate or adhesive."
        },
        {
          "kind": "no-field-of-application",
          "text": "No field of application (permitted variations) is stated in the document we read."
        },
        {
          "kind": "unclear-status",
          "text": "Ask the maker to confirm this document is still current before you rely on it."
        },
        {
          "kind": "sheet-only",
          "text": "Only a maker’s sheet or page was available to us, not the declaration of performance or classification report behind it."
        },
        {
          "kind": "conflict",
          "text": "The page cites declaration CPR0001, but neither version we found (January 2021; version 3, September 2024) lists an acoustic foam vinyl."
        },
        {
          "kind": "conflict",
          "text": "Muraspec's article 'How do fire ratings work?' describes its wallcoverings as class B; this product's own page states class C."
        },
        {
          "kind": "unresolved",
          "text": "No declaration covering this product was found."
        }
      ],
      "conflicts": [
        "The page cites declaration CPR0001, but neither version we found (January 2021; version 3, September 2024) lists an acoustic foam vinyl.",
        "Muraspec's article 'How do fire ratings work?' describes its wallcoverings as class B; this product's own page states class C."
      ],
      "unresolved": [
        "No declaration covering this product was found."
      ],
      "status": "unclear",
      "evidenceLevel": "webpage",
      "checked": "2026-10-15"
    },
    {
      "id": "tektura-geometrics-studio-digital",
      "sourceUrl": "https://www.mrwallcover.com/advice/wallcovering-fire-ratings-uk/#product-tektura-geometrics-studio-digital",
      "manufacturer": "Tektura",
      "product": "Tektura Studio digitally printed wallcovering: Geometrics designs",
      "reference": "Technical specification sheet (undated; the file name refers to 2024)",
      "scope": "Geometrics designs printed on the Tektura Studio commercial vinyl described on the sheet. The sheet is a combined document that also covers window graphics and acoustic panels; only the wallcovering line is used here.",
      "construction": "Digitally printed vinyl laminated onto woven or non-woven fabric backing",
      "weight": "From 350 gsm",
      "classificationRaw": "Euro classification B when adhered to suitable substrate. (UK) Class 0 and 1 to BS476 part 6 and 7 when adhered to a suitable substrate. Marine fire rated on request",
      "notation": "Euro classification B",
      "classification": {
        "class": "B",
        "smoke": null,
        "droplets": null
      },
      "reading": "B (smoke and droplet subclasses not stated)",
      "classificationStandardCited": null,
      "evidence": [
        {
          "sourceId": "src-tektura-geometrics-techsheet",
          "evidenceType": "technical_sheet",
          "label": "Technical data sheet",
          "documentReference": "Geometrics technical specification",
          "testBody": null
        }
      ],
      "testedBuildup": {
        "substrate": "Not stated (\"a suitable substrate\")",
        "adhesive": null,
        "other": "The sheet says the designs are printed on commercial vinyl on woven or non-woven fabric backing. It does not say which backing, ink or print process the class refers to."
      },
      "fieldOfApplication": null,
      "limitations": [
        "A technical sheet only; no declaration of performance or classification report was found.",
        "The panel and window-film ratings on the same sheet do not apply to the wallcovering.",
        "The BS 476 Class 0 and Class 1 statement is a British national classification, not a European class, and does not convert to one. England's Approved Document B dropped national reaction-to-fire classes from 2 March 2025 (transitional arrangements apply); the Welsh and Northern Irish guidance still print them.",
        "The sheet says these designs can also be printed on other Tektura wallcoverings. The fire line does not say it covers those bases, so check the rating of the base actually ordered."
      ],
      "gaps": [
        {
          "kind": "subclass-unknown",
          "text": "The document gives the class without the full smoke and droplet subclasses; treat the missing subclass as unknown."
        },
        {
          "kind": "no-field-of-application",
          "text": "No field of application (permitted variations) is stated in the document we read."
        },
        {
          "kind": "unclear-status",
          "text": "Ask the maker to confirm this document is still current before you rely on it."
        },
        {
          "kind": "sheet-only",
          "text": "Only a maker’s sheet or page was available to us, not the declaration of performance or classification report behind it."
        },
        {
          "kind": "unresolved",
          "text": "What \"suitable substrate\" means."
        },
        {
          "kind": "unresolved",
          "text": "Which test report and laboratory support the class for the printed build-up."
        }
      ],
      "conflicts": [],
      "unresolved": [
        "What \"suitable substrate\" means.",
        "Which test report and laboratory support the class for the printed build-up."
      ],
      "status": "unclear",
      "evidenceLevel": "technical_sheet",
      "checked": "2026-10-15"
    },
    {
      "id": "tektura-dimity-weave",
      "sourceUrl": "https://www.mrwallcover.com/advice/wallcovering-fire-ratings-uk/#product-tektura-dimity-weave",
      "manufacturer": "Tektura",
      "product": "Dimity Weave",
      "reference": "Technical specification sheet",
      "scope": "The Dimity Weave product named on the sheet.",
      "construction": "Vinyl laminated onto woven cotton backing",
      "weight": "350 gsm",
      "classificationRaw": "Euroclass 13501, B s1 d0 / On request : IMO 2010 FTP part 2 - 5",
      "notation": "Euroclass 13501, B s1 d0",
      "classification": {
        "class": "B",
        "smoke": "s1",
        "droplets": "d0"
      },
      "reading": "B-s1,d0",
      "classificationStandardCited": "13501 (edition not printed)",
      "evidence": [
        {
          "sourceId": "src-tektura-dimity-weave-techsheet",
          "evidenceType": "technical_sheet",
          "label": "Technical data sheet",
          "documentReference": "Dimity Weave technical specification",
          "testBody": null
        },
        {
          "sourceId": "src-tektura-web-dimity-weave",
          "evidenceType": "webpage",
          "label": "Maker’s web page",
          "documentReference": "Dimity Weave product page",
          "testBody": null
        }
      ],
      "testedBuildup": {
        "substrate": null,
        "adhesive": null,
        "other": "The adhesive line on the sheet (Tekfix Plus; Tekfix VOV at corners) is installation guidance, not the tested build-up."
      },
      "fieldOfApplication": null,
      "limitations": [
        "A technical sheet only; no declaration of performance or classification report was found.",
        "The product web page tags it 'Euroclass B' without subclasses."
      ],
      "gaps": [
        {
          "kind": "no-buildup",
          "text": "The document we read does not name the tested substrate or adhesive."
        },
        {
          "kind": "no-field-of-application",
          "text": "No field of application (permitted variations) is stated in the document we read."
        },
        {
          "kind": "unclear-status",
          "text": "Ask the maker to confirm this document is still current before you rely on it."
        },
        {
          "kind": "sheet-only",
          "text": "Only a maker’s sheet or page was available to us, not the declaration of performance or classification report behind it."
        },
        {
          "kind": "conflict",
          "text": "Rivulet, with the same weight and backing on its sheet, is printed as B s2 d0; the two are kept separate here."
        },
        {
          "kind": "unresolved",
          "text": "The tested substrate and adhesive."
        }
      ],
      "conflicts": [
        "Rivulet, with the same weight and backing on its sheet, is printed as B s2 d0; the two are kept separate here."
      ],
      "unresolved": [
        "The tested substrate and adhesive."
      ],
      "status": "unclear",
      "evidenceLevel": "technical_sheet",
      "checked": "2026-10-15"
    },
    {
      "id": "tektura-rivulet",
      "sourceUrl": "https://www.mrwallcover.com/advice/wallcovering-fire-ratings-uk/#product-tektura-rivulet",
      "manufacturer": "Tektura",
      "product": "Rivulet",
      "reference": "Technical specification sheet",
      "scope": "The Rivulet product named on the sheet.",
      "construction": "Vinyl laminated onto woven cotton backing",
      "weight": "350 gsm",
      "classificationRaw": "Euroclass 13501, B s2 d0 / On request : IMO 2010 FTP part 2 - 5",
      "notation": "Euroclass 13501, B s2 d0",
      "classification": {
        "class": "B",
        "smoke": "s2",
        "droplets": "d0"
      },
      "reading": "B-s2,d0",
      "classificationStandardCited": "13501 (edition not printed)",
      "evidence": [
        {
          "sourceId": "src-tektura-rivulet-techsheet",
          "evidenceType": "technical_sheet",
          "label": "Technical data sheet",
          "documentReference": "Rivulet technical specification",
          "testBody": null
        },
        {
          "sourceId": "src-tektura-web-rivulet",
          "evidenceType": "webpage",
          "label": "Maker’s web page",
          "documentReference": "Rivulet product page",
          "testBody": null
        }
      ],
      "testedBuildup": {
        "substrate": null,
        "adhesive": null,
        "other": "The sheet names no tested build-up."
      },
      "fieldOfApplication": null,
      "limitations": [
        "A technical sheet only; no declaration of performance or classification report was found.",
        "The product web page tags it 'Euroclass B' without subclasses."
      ],
      "gaps": [
        {
          "kind": "no-buildup",
          "text": "The document we read does not name the tested substrate or adhesive."
        },
        {
          "kind": "no-field-of-application",
          "text": "No field of application (permitted variations) is stated in the document we read."
        },
        {
          "kind": "unclear-status",
          "text": "Ask the maker to confirm this document is still current before you rely on it."
        },
        {
          "kind": "sheet-only",
          "text": "Only a maker’s sheet or page was available to us, not the declaration of performance or classification report behind it."
        },
        {
          "kind": "unresolved",
          "text": "The tested substrate and adhesive."
        }
      ],
      "conflicts": [],
      "unresolved": [
        "The tested substrate and adhesive."
      ],
      "status": "unclear",
      "evidenceLevel": "technical_sheet",
      "checked": "2026-10-15"
    },
    {
      "id": "tektura-shimmy",
      "sourceUrl": "https://www.mrwallcover.com/advice/wallcovering-fire-ratings-uk/#product-tektura-shimmy",
      "manufacturer": "Tektura",
      "product": "Shimmy (PVC-free woven)",
      "reference": "Technical specification sheet (undated; file uploaded August 2025)",
      "scope": "The Shimmy product named on the sheet.",
      "construction": "Polyethylene and olefin weave on acrylic backing, PVC-free",
      "weight": "375 gsm",
      "classificationRaw": "Euroclass EN13501, C-s1-d0",
      "notation": "C-s1-d0",
      "classification": {
        "class": "C",
        "smoke": "s1",
        "droplets": "d0"
      },
      "reading": "C-s1,d0",
      "classificationStandardCited": "EN13501 (edition not printed)",
      "evidence": [
        {
          "sourceId": "src-tektura-shimmy-techsheet",
          "evidenceType": "technical_sheet",
          "label": "Technical data sheet",
          "documentReference": "Shimmy technical specification",
          "testBody": null
        }
      ],
      "testedBuildup": {
        "substrate": null,
        "adhesive": null,
        "other": "The sheet names no tested build-up."
      },
      "fieldOfApplication": null,
      "limitations": [
        "A technical sheet only; no declaration of performance or classification report was found.",
        "A class C product: it would not meet a class B requirement."
      ],
      "gaps": [
        {
          "kind": "no-buildup",
          "text": "The document we read does not name the tested substrate or adhesive."
        },
        {
          "kind": "no-field-of-application",
          "text": "No field of application (permitted variations) is stated in the document we read."
        },
        {
          "kind": "unclear-status",
          "text": "Ask the maker to confirm this document is still current before you rely on it."
        },
        {
          "kind": "sheet-only",
          "text": "Only a maker’s sheet or page was available to us, not the declaration of performance or classification report behind it."
        },
        {
          "kind": "unresolved",
          "text": "The tested substrate and adhesive."
        }
      ],
      "conflicts": [],
      "unresolved": [
        "The tested substrate and adhesive."
      ],
      "status": "unclear",
      "evidenceLevel": "technical_sheet",
      "checked": "2026-10-15"
    },
    {
      "id": "tektura-temple",
      "sourceUrl": "https://www.mrwallcover.com/advice/wallcovering-fire-ratings-uk/#product-tektura-temple",
      "manufacturer": "Tektura",
      "product": "Temple",
      "reference": "Technical specification sheet (undated; file uploaded August 2026) and product web page",
      "scope": "The Temple product.",
      "construction": "Vinyl laminated onto polycotton woven backing",
      "weight": "450 gsm",
      "classificationRaw": "Euroclass B (technical sheet); Euroclass C (product page)",
      "notation": null,
      "classification": {
        "class": null,
        "smoke": null,
        "droplets": null
      },
      "reading": "not resolved: the documents disagree (see gaps)",
      "classificationStandardCited": null,
      "evidence": [
        {
          "sourceId": "src-tektura-temple-techsheet",
          "evidenceType": "technical_sheet",
          "label": "Technical data sheet",
          "documentReference": "Temple technical specification",
          "testBody": null
        },
        {
          "sourceId": "src-tektura-web-temple",
          "evidenceType": "webpage",
          "label": "Maker’s web page",
          "documentReference": "Temple product page",
          "testBody": null
        }
      ],
      "testedBuildup": {
        "substrate": null,
        "adhesive": null,
        "other": "Not stated on either document."
      },
      "fieldOfApplication": null,
      "limitations": [
        "Neither document is a declaration of performance or classification report."
      ],
      "gaps": [
        {
          "kind": "no-buildup",
          "text": "The document we read does not name the tested substrate or adhesive."
        },
        {
          "kind": "no-field-of-application",
          "text": "No field of application (permitted variations) is stated in the document we read."
        },
        {
          "kind": "unclear-status",
          "text": "Ask the maker to confirm this document is still current before you rely on it."
        },
        {
          "kind": "sheet-only",
          "text": "Only a maker’s sheet or page was available to us, not the declaration of performance or classification report behind it."
        },
        {
          "kind": "conflict",
          "text": "The technical sheet says Euroclass B and the product page says Euroclass C. We have not chosen between them."
        },
        {
          "kind": "unresolved",
          "text": "Which class is current, and the declaration or report behind it."
        }
      ],
      "conflicts": [
        "The technical sheet says Euroclass B and the product page says Euroclass C. We have not chosen between them."
      ],
      "unresolved": [
        "Which class is current, and the declaration or report behind it."
      ],
      "status": "unclear",
      "evidenceLevel": "technical_sheet",
      "checked": "2026-10-15"
    },
    {
      "id": "tektura-tiburon-shagreen",
      "sourceUrl": "https://www.mrwallcover.com/advice/wallcovering-fire-ratings-uk/#product-tektura-tiburon-shagreen",
      "manufacturer": "Tektura",
      "product": "Tiburon Shagreen",
      "reference": "Technical specification sheet (undated; file uploaded August 2026)",
      "scope": "The Tiburon Shagreen product named on the sheet.",
      "construction": "Vinyl laminated onto polycotton Osnaburg backing",
      "weight": "475 gsm",
      "classificationRaw": "Euroclass B / Class 0 and 1 to BS476 part 6 and 7 when adhered to a suitable substrate.",
      "notation": "Euroclass B",
      "classification": {
        "class": "B",
        "smoke": null,
        "droplets": null
      },
      "reading": "B (smoke and droplet subclasses not stated)",
      "classificationStandardCited": null,
      "evidence": [
        {
          "sourceId": "src-tektura-tiburon-shagreen-techsheet",
          "evidenceType": "technical_sheet",
          "label": "Technical data sheet",
          "documentReference": "Tiburon Shagreen technical specification",
          "testBody": null
        }
      ],
      "testedBuildup": {
        "substrate": "Not stated (\"a suitable substrate\")",
        "adhesive": null,
        "other": "The adhesive line (Tekfix Plus; Tekfix VOV at corners) is installation guidance."
      },
      "fieldOfApplication": null,
      "limitations": [
        "A technical sheet only; no declaration of performance or classification report was found.",
        "The BS 476 Class 0 and Class 1 statement is a British national classification, not a European class, and does not convert to one. England's Approved Document B dropped national reaction-to-fire classes from 2 March 2025 (transitional arrangements apply); the Welsh and Northern Irish guidance still print them."
      ],
      "gaps": [
        {
          "kind": "subclass-unknown",
          "text": "The document gives the class without the full smoke and droplet subclasses; treat the missing subclass as unknown."
        },
        {
          "kind": "no-field-of-application",
          "text": "No field of application (permitted variations) is stated in the document we read."
        },
        {
          "kind": "unclear-status",
          "text": "Ask the maker to confirm this document is still current before you rely on it."
        },
        {
          "kind": "sheet-only",
          "text": "Only a maker’s sheet or page was available to us, not the declaration of performance or classification report behind it."
        },
        {
          "kind": "unresolved",
          "text": "The tested substrate and adhesive."
        },
        {
          "kind": "unresolved",
          "text": "The smoke and droplet subclasses."
        }
      ],
      "conflicts": [],
      "unresolved": [
        "The tested substrate and adhesive.",
        "The smoke and droplet subclasses."
      ],
      "status": "unclear",
      "evidenceLevel": "technical_sheet",
      "checked": "2026-10-15"
    },
    {
      "id": "vescom-vinyl-350-white",
      "sourceUrl": "https://www.mrwallcover.com/advice/wallcovering-fire-ratings-uk/#product-vescom-vinyl-350-white",
      "manufacturer": "Vescom",
      "product": "Vinyl wallcovering, 350 g/m², plain white, not embossed",
      "reference": "Classification report 2023-Efectis-R000709 (August 2023); declaration of performance DOP-CPR-01006",
      "scope": "One plain white, non-embossed 350 g/m² vinyl as tested. Vescom files the same report under four printed (+print) design names, which the report does not describe.",
      "construction": "Vinyl on woven cotton backing, 0.45 mm",
      "weight": "350 g/m²",
      "classificationRaw": "B - s1, d0",
      "notation": "B - s1, d0",
      "classification": {
        "class": "B",
        "smoke": "s1",
        "droplets": "d0"
      },
      "reading": "B-s1,d0",
      "classificationStandardCited": "EN 13501-1:2018",
      "evidence": [
        {
          "sourceId": "src-vescom-f1546-efectis-350",
          "evidenceType": "classification_report",
          "label": "Classification report",
          "documentReference": "2023-Efectis-R000709",
          "testBody": "Efectis Nederland (notified body 1234)"
        },
        {
          "sourceId": "src-vescom-f16185-dop-01006",
          "evidenceType": "declaration_of_performance",
          "label": "Declaration of performance",
          "documentReference": "DOP-CPR-01006",
          "testBody": "Centexbel (notified product certification body 0493), named in the declaration"
        }
      ],
      "testedBuildup": {
        "substrate": "Calcium silicate board, 12 mm, 870 kg/m³",
        "adhesive": "Vescom 3000 at 300 g/m² wet",
        "other": "Vertical joints"
      },
      "fieldOfApplication": "The tested thickness, mass, colour (white, not embossed), substrate, adhesive and joints only; no wider substrate class is stated.",
      "limitations": [
        "The field of application is a single colour, texture and adhesive.",
        "The declaration gives the intended use as internal walls or partitions of A2-s1,d0 or better, fixed with adhesive.",
        "The declaration names Centexbel certificate 0493-CPR-W023, which we did not read. It does not cite this Efectis report, so we have not confirmed that the report underlies the declaration."
      ],
      "gaps": [
        {
          "kind": "conflict",
          "text": "Filed under printed design names that the report does not cover."
        },
        {
          "kind": "conflict",
          "text": "Other Vescom vinyl evidence uses Vescom 2000 on 11 mm calcium silicate; this report uses Vescom 3000 on 12 mm board."
        },
        {
          "kind": "unresolved",
          "text": "Whether printed, coloured or embossed 350 g/m² designs fall under this report."
        }
      ],
      "conflicts": [
        "Filed under printed design names that the report does not cover.",
        "Other Vescom vinyl evidence uses Vescom 2000 on 11 mm calcium silicate; this report uses Vescom 3000 on 12 mm board."
      ],
      "unresolved": [
        "Whether printed, coloured or embossed 350 g/m² designs fall under this report."
      ],
      "status": "current",
      "evidenceLevel": "classification_report",
      "checked": "2026-10-15"
    },
    {
      "id": "vescom-vinyl-family-360-850",
      "sourceUrl": "https://www.mrwallcover.com/advice/wallcovering-fire-ratings-uk/#product-vescom-vinyl-family-360-850",
      "manufacturer": "Vescom",
      "product": "Cotton-backed vinyl wallcovering, FR treated, 360 to 850 g/m² (family declaration)",
      "reference": "Declaration of performance DOP-CPR-01001 (August 2024); certificate 0493-CPR-W014",
      "scope": "A mass range, not one design. The certificate annex lists Vescom vinyl wallcoverings and digitally printed vinyl.",
      "construction": "Vinyl on cotton backing",
      "weight": "360–850 g/m² (declaration); 350–800 g/m² (certificate)",
      "classificationRaw": "EN 13501-1 B-s2, d0",
      "notation": "B-s2, d0",
      "classification": {
        "class": "B",
        "smoke": "s2",
        "droplets": "d0"
      },
      "reading": "B-s2,d0",
      "classificationStandardCited": "EN 13501-1",
      "evidence": [
        {
          "sourceId": "src-vescom-f16184-dop-01001",
          "evidenceType": "declaration_of_performance",
          "label": "Declaration of performance",
          "documentReference": "DOP-CPR-01001",
          "testBody": null
        },
        {
          "sourceId": "src-vescom-f103-ce-vinyl",
          "evidenceType": "certificate",
          "label": "Certificate",
          "documentReference": "0493-CPR-W014",
          "testBody": "Certificate by Centexbel (notified product certification body 0493); tests by CREPIM (annex)"
        },
        {
          "sourceId": "src-vescom-f567-efectis-2012",
          "evidenceType": "classification_report",
          "label": "Classification report",
          "documentReference": "2012-Efectis-R9438d",
          "testBody": "Efectis Nederland (notified body 1234)"
        }
      ],
      "testedBuildup": {
        "substrate": "Calcium silicate board, 11 mm, 870 kg/m³",
        "adhesive": "Vescom 2000 at 170 g/m² (CREPIM DO-18-0159, bound with the certificate)",
        "other": "Vertical joints"
      },
      "fieldOfApplication": "Calcium silicate board and other A1 or A2-s1,d0 substrates of over 652.5 kg/m³, excluding plasterboard, with vertical joints (certificate p. 2).",
      "limitations": [
        "Plasterboard is expressly excluded from the certificate’s field of application.",
        "A family declaration: individual designs can have their own, different results.",
        "The declaration gives the intended use as internal walls or partitions of A2-s1,d0 or better, fixed with adhesive."
      ],
      "gaps": [
        {
          "kind": "stated-expiry-passed",
          "text": "0493-CPR-W014 states a validity that ended on 31 July 2023 (printed as “latest on July 31st 2023”); ask the maker for the current document."
        },
        {
          "kind": "unclear-status",
          "text": "Ask the maker to confirm this document is still current before you rely on it."
        },
        {
          "kind": "conflict",
          "text": "The 2024 declaration gives 360–850 g/m², while the 2017 declaration and the certificate give 350–800 g/m²."
        },
        {
          "kind": "conflict",
          "text": "A 2012 Vescom classification report on a 460 g/m² vinyl was tested on paper-faced plasterboard, which this certificate excludes."
        },
        {
          "kind": "unresolved",
          "text": "Whether a certificate replaced 0493-CPR-W014 after its stated validity ended."
        }
      ],
      "conflicts": [
        "The 2024 declaration gives 360–850 g/m², while the 2017 declaration and the certificate give 350–800 g/m².",
        "A 2012 Vescom classification report on a 460 g/m² vinyl was tested on paper-faced plasterboard, which this certificate excludes."
      ],
      "unresolved": [
        "Whether a certificate replaced 0493-CPR-W014 after its stated validity ended."
      ],
      "status": "unclear",
      "evidenceLevel": "declaration_of_performance",
      "checked": "2026-10-15"
    },
    {
      "id": "vescom-colour-choice-protect",
      "sourceUrl": "https://www.mrwallcover.com/advice/wallcovering-fire-ratings-uk/#product-vescom-colour-choice-protect",
      "manufacturer": "Vescom",
      "product": "Colour Choice+Protect (1126.01 PRO to 1126.75 PRO)",
      "reference": "Product page and specsheet; Protect family declaration DOP-CPR-01002 and certificate 0493-CPR-W015; linked report DO-18-0159",
      "scope": "75 colourways with the PRO suffix, which carry the Protect film.",
      "construction": "Plain vinyl on woven cotton backing with Vescom Protect film",
      "weight": "About 460 g/m²",
      "classificationRaw": "EN 13501 , B, s2 - d0",
      "notation": "B, s2 - d0",
      "classification": {
        "class": "B",
        "smoke": "s2",
        "droplets": "d0"
      },
      "reading": "B-s2,d0",
      "classificationStandardCited": "EN 13501 (edition not printed)",
      "evidence": [
        {
          "sourceId": "src-vescom-specsheet-ccp-gb",
          "evidenceType": "technical_sheet",
          "label": "Technical data sheet",
          "documentReference": "Colour Choice+Protect specsheet (en-GB)",
          "testBody": null
        },
        {
          "sourceId": "src-vescom-page-colour-choice-protect",
          "evidenceType": "webpage",
          "label": "Maker’s web page",
          "documentReference": "Product page",
          "testBody": null
        },
        {
          "sourceId": "src-vescom-f2512-dop-01002",
          "evidenceType": "declaration_of_performance",
          "label": "Declaration of performance",
          "documentReference": "DOP-CPR-01002",
          "testBody": "Centexbel (notified product certification body 0493), named in the declaration"
        },
        {
          "sourceId": "src-vescom-f278-ce-vinyl-protect",
          "evidenceType": "certificate",
          "label": "Certificate",
          "documentReference": "0493-CPR-W015",
          "testBody": "Centexbel (notified body 0493); classification by MPA Dresden (0767) per annex"
        },
        {
          "sourceId": "src-vescom-f18987-ccprotect-crepim",
          "evidenceType": "classification_report",
          "label": "Classification report",
          "documentReference": "DO-18-0159\\A-R1",
          "testBody": "CREPIM"
        }
      ],
      "testedBuildup": {
        "substrate": "Calcium silicate board, 11 mm, 870 kg/m³ (in the linked report)",
        "adhesive": "Vescom 2000 at 170 g/m² (in the linked report)",
        "other": "The linked report tests Vescom Rainy, a cotton-backed vinyl of 0.46–0.8 kg/m², with no Protect layer described."
      },
      "fieldOfApplication": "In the linked report: no variation in composition; any colour and pattern; calcium silicate board and A1 or A2-s1,d0 substrates above 652.5 kg/m³, excluding plasterboard.",
      "limitations": [
        "The specsheet and page give the class only. The page also links Vescom's Protect family declaration DOP-CPR-01002 (July 2017: B-s2,d0 for cotton-backed vinyl with Vescom Protect, 370–480 g/m²) and certificate 0493-CPR-W015, stated valid 'latest on July 31st 2023'. The certificate describes a 370 g/m² build-up on calcium silicate with Vescom 2000. The MPA Dresden classification behind it (20180730/01, Pleso + Protect) is limited to the tested 356 g/m² and 0.31 mm and excludes gypsum boards. No Protect test at about 460 g/m² was found.",
        "Vescom's product page also lists Colour Choice+Protect as B s2 d0."
      ],
      "gaps": [
        {
          "kind": "stated-expiry-passed",
          "text": "0493-CPR-W015 states a validity that ended on 31 July 2023 (printed as “latest on July 31st 2023”); ask the maker for the current document."
        },
        {
          "kind": "stated-expiry-passed",
          "text": "DO-18-0159\\A-R1 states a validity that ended on 21 August 2023 (printed as “5 years as from 21/08/2018”); ask the maker for the current document."
        },
        {
          "kind": "unclear-status",
          "text": "Ask the maker to confirm this document is still current before you rely on it."
        },
        {
          "kind": "conflict",
          "text": "The report linked from the product page (CREPIM DO-18-0159\\A-R1, 'VESCOM - RAINY') never names Colour Choice or Protect. It describes only a cotton backing and vinyl topcoat, with no variation in composition allowed. It is one of the two reports behind Vescom's non-Protect vinyl family certificate 0493-CPR-W014, not a Protect-specific test."
        },
        {
          "kind": "unresolved",
          "text": "Whether Vescom holds a classification of Colour Choice+Protect at about 460 g/m² with the Protect laminate, and whether certificate W015 was renewed after July 2023."
        },
        {
          "kind": "unresolved",
          "text": "Whether the linked report, printed as valid for five years from August 2018, has been renewed."
        }
      ],
      "conflicts": [
        "The report linked from the product page (CREPIM DO-18-0159\\A-R1, 'VESCOM - RAINY') never names Colour Choice or Protect. It describes only a cotton backing and vinyl topcoat, with no variation in composition allowed. It is one of the two reports behind Vescom's non-Protect vinyl family certificate 0493-CPR-W014, not a Protect-specific test."
      ],
      "unresolved": [
        "Whether Vescom holds a classification of Colour Choice+Protect at about 460 g/m² with the Protect laminate, and whether certificate W015 was renewed after July 2023.",
        "Whether the linked report, printed as valid for five years from August 2018, has been renewed."
      ],
      "status": "unclear",
      "evidenceLevel": "declaration_of_performance",
      "checked": "2026-10-15"
    },
    {
      "id": "vescom-porak-print",
      "sourceUrl": "https://www.mrwallcover.com/advice/wallcovering-fire-ratings-uk/#product-vescom-porak-print",
      "manufacturer": "Vescom",
      "product": "Porak+print (1041)",
      "reference": "Classification report 2024-Efectis-R001444 (January 2025)",
      "scope": "Porak+print as tested, in any colour with or without print.",
      "construction": "40% recycled polyester weave coated on both sides with acrylate, FR treated, 0.35 mm",
      "weight": "330 g/m²",
      "classificationRaw": "B - s2, d0",
      "notation": "B - s2, d0",
      "classification": {
        "class": "B",
        "smoke": "s2",
        "droplets": "d0"
      },
      "reading": "B-s2,d0",
      "classificationStandardCited": "EN 13501-1:2018",
      "evidence": [
        {
          "sourceId": "src-vescom-f16802-efectis-porak",
          "evidenceType": "classification_report",
          "label": "Classification report",
          "documentReference": "2024-Efectis-R001444",
          "testBody": "Efectis Nederland (notified body 1234)"
        }
      ],
      "testedBuildup": {
        "substrate": "Non-combustible substrate, class A1 or A2, 870 kg/m³ (board type not named)",
        "adhesive": "Vescom 2500 at 200 g/m² wet",
        "other": "Vertical joints"
      },
      "fieldOfApplication": "The tested thickness and mass, any colour with or without print, and the substrate, adhesive and joints as tested.",
      "limitations": [
        "Valid for the tested build-up only; the report sets no validity period beyond the standard and national law."
      ],
      "gaps": [
        {
          "kind": "unresolved",
          "text": "Whether the printed layer on a given order matches the tested description."
        }
      ],
      "conflicts": [],
      "unresolved": [
        "Whether the printed layer on a given order matches the tested description."
      ],
      "status": "current",
      "evidenceLevel": "classification_report",
      "checked": "2026-10-15"
    },
    {
      "id": "vescom-woven-textile-13004",
      "sourceUrl": "https://www.mrwallcover.com/advice/wallcovering-fire-ratings-uk/#product-vescom-woven-textile-13004",
      "manufacturer": "Vescom",
      "product": "Woven textile on paper backing, silk, wool and synthetic fibres (family declaration DOP-CPR-13004; tested quality 69-2341)",
      "reference": "Classification report 22965F (October 2023)",
      "scope": "Only the tested quality, colour and weave. The report was issued to the textile producer, Tapetex BV, and is in Vescom’s document library; Vescom’s declaration for this fibre family cites it.",
      "construction": "Woven silk, wool, polyester and nylon on a reinforced paper backing, 0.4 mm",
      "weight": "305 g/m²",
      "classificationRaw": "B - s1, d0",
      "notation": "B - s1, d0",
      "classification": {
        "class": "B",
        "smoke": "s1",
        "droplets": "d0"
      },
      "reading": "B-s1,d0",
      "classificationStandardCited": "EN 13501-1:2018",
      "evidence": [
        {
          "sourceId": "src-vescom-f18446-tapetex-69-2341",
          "evidenceType": "classification_report",
          "label": "Classification report",
          "documentReference": "22965F version 1",
          "testBody": "Warringtonfire, Ghent"
        },
        {
          "sourceId": "src-vescom-f18455-dop-13004",
          "evidenceType": "declaration_of_performance",
          "label": "Declaration of performance",
          "documentReference": "DOP-CPR-13004",
          "testBody": "Warringtonfire Ghent (notified testing laboratory 1173; the declaration calls 22965F a test report)"
        }
      ],
      "testedBuildup": {
        "substrate": "Calcium silicate board, 12 mm, 870 kg/m³, class A1",
        "adhesive": "A starch and resin dispersion wallcovering adhesive at 200 g/m² wet",
        "other": "No fire retardant used; vertical joints"
      },
      "fieldOfApplication": "Substrates of at least 652.5 kg/m³, at least 9 mm thick and A2-s1,d0 or better, excluding paper-faced gypsum plasterboard; no air gap; vertical joints permitted; a starch and resin dispersion adhesive.",
      "limitations": [
        "Paper-faced plasterboard is expressly excluded.",
        "The tested adhesive is not one of the Vescom-branded adhesives.",
        "Differences in composition, thickness, density or colour may invalidate the result for a variant."
      ],
      "gaps": [
        {
          "kind": "conflict",
          "text": "Three other reports on related textile qualities in the same library allow no joints at all."
        },
        {
          "kind": "unresolved",
          "text": "How the relationship between the textile producer and Vescom affects which declaration applies to an order."
        }
      ],
      "conflicts": [
        "Three other reports on related textile qualities in the same library allow no joints at all."
      ],
      "unresolved": [
        "How the relationship between the textile producer and Vescom affects which declaration applies to an order."
      ],
      "status": "current",
      "evidenceLevel": "classification_report",
      "checked": "2026-10-15"
    },
    {
      "id": "vescom-digital-nonwoven-13008",
      "sourceUrl": "https://www.mrwallcover.com/advice/wallcovering-fire-ratings-uk/#product-vescom-digital-nonwoven-13008",
      "manufacturer": "Vescom",
      "product": "Digitally printed one-layer non-woven (cellulose and polyester fibres)",
      "reference": "Declaration of performance DOP-CPR-13008 (January 2023)",
      "scope": "A generic product type; the product type reference is on the roll labels.",
      "construction": "Digitally printed one-layer non-woven, cellulose and polyester fibres",
      "weight": null,
      "classificationRaw": "EN 13501-1 B-s1, d0",
      "notation": "B-s1, d0",
      "classification": {
        "class": "B",
        "smoke": "s1",
        "droplets": "d0"
      },
      "reading": "B-s1,d0",
      "classificationStandardCited": "EN 13501-1",
      "evidence": [
        {
          "sourceId": "src-vescom-f2534-dop-13008",
          "evidenceType": "declaration_of_performance",
          "label": "Declaration of performance",
          "documentReference": "DOP-CPR-13008",
          "testBody": "Efectis (notified body 1234, named in the declaration)"
        }
      ],
      "testedBuildup": {
        "substrate": null,
        "adhesive": null,
        "other": "The declaration cites report 2022-Efectis-R001208, which was not available to read."
      },
      "fieldOfApplication": null,
      "limitations": [
        "The declaration gives the intended use as internal walls or partitions of A2-s1,d0 or better, fixed with adhesive."
      ],
      "gaps": [
        {
          "kind": "no-buildup",
          "text": "The document we read does not name the tested substrate or adhesive."
        },
        {
          "kind": "no-field-of-application",
          "text": "No field of application (permitted variations) is stated in the document we read."
        },
        {
          "kind": "unclear-status",
          "text": "Ask the maker to confirm this document is still current before you rely on it."
        },
        {
          "kind": "unresolved",
          "text": "The tested substrate, adhesive and joints are unknown without the classification report."
        }
      ],
      "conflicts": [],
      "unresolved": [
        "The tested substrate, adhesive and joints are unknown without the classification report."
      ],
      "status": "unclear",
      "evidenceLevel": "declaration_of_performance",
      "checked": "2026-10-15"
    },
    {
      "id": "arte-moire-sauvage",
      "sourceUrl": "https://www.mrwallcover.com/advice/wallcovering-fire-ratings-uk/#product-arte-moire-sauvage",
      "manufacturer": "Arte International",
      "product": "Moire Sauvage (Arte Contract), contract vinyl type 07A",
      "reference": "References 47253A, 47254A, 47258A, 47260A, 47261A, 47264A, 47265A, 47269A and 67700 to 67705",
      "scope": "The 14 Moire Sauvage references listed in the declaration. Not other Arte Contract designs, although the certificate groups them in one family.",
      "construction": "Vinyl on non-woven backing, Type II",
      "weight": "About 460 g/m² (as printed on the specification sheet)",
      "classificationRaw": "B-S2,d0 (declaration of performance); B-s2, d0 (specification sheet)",
      "notation": "B-S2,d0",
      "classification": {
        "class": "B",
        "smoke": "s2",
        "droplets": "d0"
      },
      "reading": "B-s2,d0",
      "classificationStandardCited": "EN 13501-1 (edition not printed)",
      "evidence": [
        {
          "sourceId": "src-arte-dop-moire-sauvage-uk",
          "evidenceType": "declaration_of_performance",
          "label": "Declaration of performance",
          "documentReference": "DoP-CPR-24-3959",
          "testBody": "Centexbel (notified body 0493)"
        },
        {
          "sourceId": "src-centexbel-cocp-0493-cpr-w038",
          "evidenceType": "certificate",
          "label": "Certificate",
          "documentReference": "0493-CPR-W038",
          "testBody": "CREPIM (four test reports, 12 December 2022 to 25 April 2023); certificate issued by Centexbel (notified body 0493)"
        },
        {
          "sourceId": "src-arte-spec-47253a",
          "evidenceType": "technical_sheet",
          "label": "Technical data sheet",
          "documentReference": "Specification sheet 47253A",
          "testBody": null
        },
        {
          "sourceId": "src-arte-us-e84-13-03217",
          "evidenceType": "test_report",
          "label": "Test report",
          "documentReference": "13-03217",
          "testBody": "Commercial Testing Company"
        }
      ],
      "testedBuildup": {
        "substrate": "Fibre-cement board, vertical joints (density and thickness not stated)",
        "adhesive": "Not stated in the declaration or certificate",
        "other": "No primer, lining, air gap or fixing described."
      },
      "fieldOfApplication": "The certificate covers decorative Type II and Type III FR-treated vinyl on woven or non-woven backing, 451 to 790 g/m², glued on fibre-cement with vertical joints. No other substrate or adhesive is expressly permitted.",
      "limitations": [
        "Nothing read extends the class to plasterboard, plaster, painted walls, lining paper or timber.",
        "Arte's specification sheet 47253A recommends Arte Clearpro or a good quality dispersion adhesive; the adhesive behind the classification is not stated."
      ],
      "gaps": [
        {
          "kind": "conflict",
          "text": "The declaration states System 3, while the certificate it cites is issued under System 1."
        },
        {
          "kind": "conflict",
          "text": "The \"US Class A\" file linked from the product page is a 2013 test of a different product, not Moire Sauvage."
        },
        {
          "kind": "conflict",
          "text": "The declaration says Centexbel performed the type testing; the certificate annex bases the class on four CREPIM test reports."
        },
        {
          "kind": "unresolved",
          "text": "Which adhesive and board were used in the underlying tests, which are not published."
        },
        {
          "kind": "unresolved",
          "text": "Whether the class holds on plasterboard or painted plaster."
        },
        {
          "kind": "unresolved",
          "text": "Which UK approved body, if any, supports the UKCA mark on the declaration: the documents it relies on were issued by Centexbel as an EU notified body (0493) under Regulation (EU) 305/2011."
        }
      ],
      "conflicts": [
        "The declaration states System 3, while the certificate it cites is issued under System 1.",
        "The \"US Class A\" file linked from the product page is a 2013 test of a different product, not Moire Sauvage.",
        "The declaration says Centexbel performed the type testing; the certificate annex bases the class on four CREPIM test reports."
      ],
      "unresolved": [
        "Which adhesive and board were used in the underlying tests, which are not published.",
        "Whether the class holds on plasterboard or painted plaster.",
        "Which UK approved body, if any, supports the UKCA mark on the declaration: the documents it relies on were issued by Centexbel as an EU notified body (0493) under Regulation (EU) 305/2011."
      ],
      "status": "current",
      "evidenceLevel": "declaration_of_performance",
      "checked": "2026-10-15"
    },
    {
      "id": "arte-le-corbusier-dots",
      "sourceUrl": "https://www.mrwallcover.com/advice/wallcovering-fire-ratings-uk/#product-arte-le-corbusier-dots",
      "manufacturer": "Arte International",
      "product": "Dots (Le Corbusier collection), type 01",
      "reference": "References 31000 to 31039 (40 colourways)",
      "scope": "The 40 Dots references listed in the declaration. The group classification report also lists other Arte collection names.",
      "construction": "Wallpaper on non-woven backing with relief ink dots",
      "weight": null,
      "classificationRaw": "B-S1,d0",
      "notation": "B-S1,d0",
      "classification": {
        "class": "B",
        "smoke": "s1",
        "droplets": "d0"
      },
      "reading": "B-s1,d0",
      "classificationStandardCited": "EN 13501-1 (edition not printed in the declaration)",
      "evidence": [
        {
          "sourceId": "src-arte-dop-le-corbusier-dots-uk",
          "evidenceType": "declaration_of_performance",
          "label": "Declaration of performance",
          "documentReference": "DoP-CPR-15-3350",
          "testBody": "Centexbel (notified body 0493)"
        },
        {
          "sourceId": "src-centexbel-report-19-721",
          "evidenceType": "classification_report",
          "label": "Classification report",
          "documentReference": "19/721",
          "testBody": "Aitex (22AN6585 and 22AN6587, 29 July 2022); report issued by Centexbel (notified body 0493)"
        },
        {
          "sourceId": "src-arte-spec-31000",
          "evidenceType": "technical_sheet",
          "label": "Technical data sheet",
          "documentReference": "Specification sheet 31000",
          "testBody": null
        }
      ],
      "testedBuildup": {
        "substrate": "End-use substrates of 1,350 kg/m³ or more, class A2-s1,d0 or A1",
        "adhesive": "Starch glue at 200 g/m²",
        "other": "The group report covers 130 to 592 g/m²."
      },
      "fieldOfApplication": "Starch glue at 200 g/m² on substrates of at least 1,350 kg/m³ classed A2-s1,d0 or A1 (classification report). No other variation is stated.",
      "limitations": [
        "A substrate of at least 1,350 kg/m³ is far denser than standard plasterboard; the report does not mention plasterboard, plaster or painted walls.",
        "Arte's specification sheet 31000 recommends Arte Clearpro or a good quality dispersion adhesive rather than the starch glue in the report.",
        "The declaration says Centexbel performed the type testing; the classification report names Aitex test reports as its basis."
      ],
      "gaps": [
        {
          "kind": "conflict",
          "text": "The declaration is dated April 2022, but the current version of the classification report rests on tests dated July 2022."
        },
        {
          "kind": "unresolved",
          "text": "Whether the 2022 declaration has been checked against the current report."
        },
        {
          "kind": "unresolved",
          "text": "Which colourways were tested."
        },
        {
          "kind": "unresolved",
          "text": "Which UK approved body, if any, supports the UKCA mark on the declaration: the documents it relies on were issued by Centexbel as an EU notified body (0493) under Regulation (EU) 305/2011."
        }
      ],
      "conflicts": [
        "The declaration is dated April 2022, but the current version of the classification report rests on tests dated July 2022."
      ],
      "unresolved": [
        "Whether the 2022 declaration has been checked against the current report.",
        "Which colourways were tested.",
        "Which UK approved body, if any, supports the UKCA mark on the declaration: the documents it relies on were issued by Centexbel as an EU notified body (0493) under Regulation (EU) 305/2011."
      ],
      "status": "current",
      "evidenceLevel": "declaration_of_performance",
      "checked": "2026-10-15"
    },
    {
      "id": "arte-indienne-type03",
      "sourceUrl": "https://www.mrwallcover.com/advice/wallcovering-fire-ratings-uk/#product-arte-indienne-type03",
      "manufacturer": "Arte International",
      "product": "Indienne, type 03 vinyl wallpaper (Poona, Agra, Mandu, Bundi, Kerala and Kashmir)",
      "reference": "References 18300–18303, 18310–18313, 18320–18322, 18330–18333, 18340–18351 and 18360–18371 (39 references, as listed in the declaration)",
      "scope": "The six Indienne designs listed in the declaration. The group report also lists other collections.",
      "construction": "Vinyl with water-based ink (backing not stated in the documents read)",
      "weight": "The group report covers about 250 to 610 g/m²",
      "classificationRaw": "B-s2,d0",
      "notation": "B-s2,d0",
      "classification": {
        "class": "B",
        "smoke": "s2",
        "droplets": "d0"
      },
      "reading": "B-s2,d0",
      "classificationStandardCited": "EN 13501-1:2019 (report 19/720); no edition in the declaration",
      "evidence": [
        {
          "sourceId": "src-arte-dop-indienne-uk",
          "evidenceType": "declaration_of_performance",
          "label": "Declaration of performance",
          "documentReference": "DoP-CPR-100001000026-00020",
          "testBody": "Centexbel (notified body 0493)"
        },
        {
          "sourceId": "src-centexbel-report-19-720",
          "evidenceType": "classification_report",
          "label": "Classification report",
          "documentReference": "19/720",
          "testBody": "Aitex (2024AN2800 and 2019AN2798, both dated 13 January 2025); report issued by Centexbel (notified body 0493)"
        }
      ],
      "testedBuildup": {
        "substrate": "End-use substrates of 1,350 kg/m³ or more, class A2-s1,d0 or A1",
        "adhesive": "Starch glue at 200 g/m²",
        "other": null
      },
      "fieldOfApplication": "Starch glue at 200 g/m² on dense A2-s1,d0 or A1 substrates (classification report).",
      "limitations": [
        "The field of application does not mention plasterboard, plaster or painted walls.",
        "The declaration says Centexbel performed the type testing; the classification report names Aitex test reports as its basis."
      ],
      "gaps": [
        {
          "kind": "unresolved",
          "text": "Whether the report re-dated in September 2026 changed the field of application relied on by the April 2026 declaration."
        },
        {
          "kind": "unresolved",
          "text": "Which UK approved body, if any, supports the UKCA mark on the declaration: the documents it relies on were issued by Centexbel as an EU notified body (0493) under Regulation (EU) 305/2011."
        }
      ],
      "conflicts": [],
      "unresolved": [
        "Whether the report re-dated in September 2026 changed the field of application relied on by the April 2026 declaration.",
        "Which UK approved body, if any, supports the UKCA mark on the declaration: the documents it relies on were issued by Centexbel as an EU notified body (0493) under Regulation (EU) 305/2011."
      ],
      "status": "current",
      "evidenceLevel": "declaration_of_performance",
      "checked": "2026-10-15"
    },
    {
      "id": "arte-tapisseries-brocade-ramage",
      "sourceUrl": "https://www.mrwallcover.com/advice/wallcovering-fire-ratings-uk/#product-arte-tapisseries-brocade-ramage",
      "manufacturer": "Arte International",
      "product": "Les Tapisseries: Brocade and Ramage, type 06D textile",
      "reference": "References 97840 to 97842 and 97830 to 97832",
      "scope": "The Brocade and Ramage references in the declaration.",
      "construction": "Textile wallcovering (backing not stated in the documents read)",
      "weight": "The group report covers 580 to 800 g/m²",
      "classificationRaw": "C-s1,d0 (DoP); C - s1, d0 (report)",
      "notation": "C-s1,d0",
      "classification": {
        "class": "C",
        "smoke": "s1",
        "droplets": "d0"
      },
      "reading": "C-s1,d0",
      "classificationStandardCited": "EN 13501-1:2007+A1:2009 (report 20/1150); no edition in the declaration",
      "evidence": [
        {
          "sourceId": "src-arte-dop-les-tapisseries-06d-uk",
          "evidenceType": "declaration_of_performance",
          "label": "Declaration of performance",
          "documentReference": "DoP-CPR-100003000026-00040/2",
          "testBody": "Centexbel (notified body 0493)"
        },
        {
          "sourceId": "src-centexbel-report-20-1150",
          "evidenceType": "classification_report",
          "label": "Classification report",
          "documentReference": "20/1150",
          "testBody": "AITEX (2024AN2468, 23 December 2024; 2026AN1102, 21 May 2026); report issued by Centexbel (notified body 0493)"
        }
      ],
      "testedBuildup": {
        "substrate": "End-use substrates of 1,350 kg/m³ or more, class A2-s1,d0 or A1",
        "adhesive": "Starch glue at 200 g/m²",
        "other": null
      },
      "fieldOfApplication": "Starch glue at 200 g/m² on dense A2-s1,d0 or A1 substrates (classification report).",
      "limitations": [
        "A class C product: it would not meet a class B requirement.",
        "The declaration says Centexbel performed the type testing; the classification report names Aitex test reports as its basis."
      ],
      "gaps": [
        {
          "kind": "unclear-status",
          "text": "Ask the maker to confirm this document is still current before you rely on it."
        },
        {
          "kind": "conflict",
          "text": "The declaration cites report 20/1155; the report linked from the product page is numbered 20/1150."
        },
        {
          "kind": "conflict",
          "text": "The declaration (April 2026) predates the linked report (August 2026)."
        },
        {
          "kind": "unresolved",
          "text": "Whether report 20/1155 exists separately, and whether the declaration has been reissued."
        },
        {
          "kind": "unresolved",
          "text": "Which UK approved body, if any, supports the UKCA mark on the declaration: the documents it relies on were issued by Centexbel as an EU notified body (0493) under Regulation (EU) 305/2011."
        }
      ],
      "conflicts": [
        "The declaration cites report 20/1155; the report linked from the product page is numbered 20/1150.",
        "The declaration (April 2026) predates the linked report (August 2026)."
      ],
      "unresolved": [
        "Whether report 20/1155 exists separately, and whether the declaration has been reissued.",
        "Which UK approved body, if any, supports the UKCA mark on the declaration: the documents it relies on were issued by Centexbel as an EU notified body (0493) under Regulation (EU) 305/2011."
      ],
      "status": "unclear",
      "evidenceLevel": "classification_report",
      "checked": "2026-10-15"
    },
    {
      "id": "arte-tapisseries-collines",
      "sourceUrl": "https://www.mrwallcover.com/advice/wallcovering-fire-ratings-uk/#product-arte-tapisseries-collines",
      "manufacturer": "Arte International",
      "product": "Les Tapisseries: Collines, type 06C textile",
      "reference": "References 97900 to 97902",
      "scope": "The Collines references in the declaration.",
      "construction": "Non-woven substrate with fabric (classification report)",
      "weight": "The group report covers 370 to 1,000 g/m²",
      "classificationRaw": "D - s1, d0 (classification report, June 2026); C-s1,d0 (declaration of performance, April 2026)",
      "notation": null,
      "classification": {
        "class": null,
        "smoke": null,
        "droplets": null
      },
      "reading": "not resolved: the documents disagree (see gaps)",
      "classificationStandardCited": null,
      "evidence": [
        {
          "sourceId": "src-centexbel-report-18-667",
          "evidenceType": "classification_report",
          "label": "Classification report",
          "documentReference": "18/667",
          "testBody": "Aitex (2024AN2454, 2026AN0788, 2026AN1098); report issued by Centexbel (notified body 0493)"
        },
        {
          "sourceId": "src-arte-dop-les-tapisseries-06c-uk",
          "evidenceType": "declaration_of_performance",
          "label": "Declaration of performance",
          "documentReference": "DoP-CPR-100003000026-00040/5",
          "testBody": "Centexbel (notified body 0493)"
        }
      ],
      "testedBuildup": {
        "substrate": "End-use substrates of 1,350 kg/m³ or more, class A2-s1,d0 or A1",
        "adhesive": "Starch glue at 1 kg per 6 m² (about 167 g/m²)",
        "other": null
      },
      "fieldOfApplication": "Starch glue on dense A2-s1,d0 or A1 substrates (classification report).",
      "limitations": [
        "On either reading this is below class B.",
        "The declaration says Centexbel performed the type testing; the classification report names Aitex test reports as its basis."
      ],
      "gaps": [
        {
          "kind": "unclear-status",
          "text": "Ask the maker to confirm this document is still current before you rely on it."
        },
        {
          "kind": "conflict",
          "text": "The declaration declares C-s1,d0 and cites report 18/667; the current version of that report gives D-s1,d0. We have not chosen between them."
        },
        {
          "kind": "unresolved",
          "text": "Which class is current for Collines; ask Arte for a reissued declaration."
        },
        {
          "kind": "unresolved",
          "text": "Which UK approved body, if any, supports the UKCA mark on the declaration: the documents it relies on were issued by Centexbel as an EU notified body (0493) under Regulation (EU) 305/2011."
        }
      ],
      "conflicts": [
        "The declaration declares C-s1,d0 and cites report 18/667; the current version of that report gives D-s1,d0. We have not chosen between them."
      ],
      "unresolved": [
        "Which class is current for Collines; ask Arte for a reissued declaration.",
        "Which UK approved body, if any, supports the UKCA mark on the declaration: the documents it relies on were issued by Centexbel as an EU notified body (0493) under Regulation (EU) 305/2011."
      ],
      "status": "unclear",
      "evidenceLevel": "classification_report",
      "checked": "2026-10-15"
    },
    {
      "id": "newmor-premier-460-nonwoven",
      "sourceUrl": "https://www.mrwallcover.com/advice/wallcovering-fire-ratings-uk/#product-newmor-premier-460-nonwoven",
      "manufacturer": "Newmor",
      "product": "Premier vinyl, 460 g/m², non-woven backing",
      "reference": "Classification report 082/BW/22 (September 2022)",
      "scope": "The Premier non-woven construction as tested (one colour).",
      "construction": "Vinyl 370 g/m² on non-woven 90 g/m², about 0.40 mm",
      "weight": "460 g/m²",
      "classificationRaw": "B–s1, d0",
      "notation": "B–s1, d0",
      "classification": {
        "class": "B",
        "smoke": "s1",
        "droplets": "d0"
      },
      "reading": "B-s1,d0",
      "classificationStandardCited": "PN-EN 13501-1:2019-02",
      "evidence": [
        {
          "sourceId": "src-newmor-cnbop-082-bw-22",
          "evidenceType": "classification_report",
          "label": "Classification report",
          "documentReference": "082/BW/22",
          "testBody": "CNBOP-PIB (notified body 1438)"
        },
        {
          "sourceId": "src-newmor-bttg-27-06093",
          "evidenceType": "test_report",
          "label": "Test report",
          "documentReference": "27/06093/02/23",
          "testBody": "BTTG (UKAS testing laboratory 1066)"
        }
      ],
      "testedBuildup": {
        "substrate": "Fibre-cement board, 8 mm",
        "adhesive": "Dixon Turner Heavy adhesive at 200 g/m²",
        "other": "No primer stated."
      },
      "fieldOfApplication": "Fibre-cement board of at least A2-s1,d0, other substrates of at least A2-s1,d0 excluding paper plasterboard, and all A1 substrates, at no less than 75% of the standard substrate density, with the named adhesive at 200 g/m².",
      "limitations": [
        "Paper plasterboard is expressly excluded.",
        "The report says it remains valid as long as composition, production and the test and classification methods do not change."
      ],
      "gaps": [
        {
          "kind": "unclear-status",
          "text": "Ask the maker to confirm this document is still current before you rely on it."
        },
        {
          "kind": "conflict",
          "text": "A separate 2023 BTTG test report (27/06093/02/23) on a sample referenced \"Premier 20oz, Nonwoven-Backed\" gives B, s2, d0, tested on 12 mm calcium silicate board with Newmor Heavy adhesive rather than the 8 mm fibre-cement board and Dixon Turner Heavy adhesive of 082/BW/22. The report states no weight in g/m², so whether it is the same construction is not established."
        }
      ],
      "conflicts": [
        "A separate 2023 BTTG test report (27/06093/02/23) on a sample referenced \"Premier 20oz, Nonwoven-Backed\" gives B, s2, d0, tested on 12 mm calcium silicate board with Newmor Heavy adhesive rather than the 8 mm fibre-cement board and Dixon Turner Heavy adhesive of 082/BW/22. The report states no weight in g/m², so whether it is the same construction is not established."
      ],
      "unresolved": [],
      "status": "unclear",
      "evidenceLevel": "classification_report",
      "checked": "2026-10-15"
    },
    {
      "id": "newmor-premier-400-nonwoven",
      "sourceUrl": "https://www.mrwallcover.com/advice/wallcovering-fire-ratings-uk/#product-newmor-premier-400-nonwoven",
      "manufacturer": "Newmor",
      "product": "Premier vinyl, 400 g/m², non-woven backing",
      "reference": "Test report 27/06068B/01/23 (February 2023)",
      "scope": "One sample as tested.",
      "construction": "Vinyl on non-woven backing",
      "weight": "400 g/m² (sample name)",
      "classificationRaw": "B, s2, d0 (results table); comment: 'probable Class B, s1, d0 but a definite Class B, s2, d0'",
      "notation": "B, s2, d0",
      "classification": {
        "class": "B",
        "smoke": "s2",
        "droplets": "d0"
      },
      "reading": "B-s2,d0",
      "classificationStandardCited": "BS EN 13501-1:2018",
      "evidence": [
        {
          "sourceId": "src-newmor-bttg-27-06068b",
          "evidenceType": "test_report",
          "label": "Test report",
          "documentReference": "27/06068B/01/23",
          "testBody": "BTTG (UKAS testing laboratory 1066)"
        }
      ],
      "testedBuildup": {
        "substrate": "Calcium silicate board, 12 mm",
        "adhesive": "Newmor Heavy adhesive",
        "other": null
      },
      "fieldOfApplication": null,
      "limitations": [
        "A test report, not a classification report: it gives s1 only as \"probable\" and s2 as definite."
      ],
      "gaps": [
        {
          "kind": "no-field-of-application",
          "text": "No field of application (permitted variations) is stated in the document we read."
        },
        {
          "kind": "unresolved",
          "text": "Which smoke subclass Newmor states in specifications for this product."
        }
      ],
      "conflicts": [],
      "unresolved": [
        "Which smoke subclass Newmor states in specifications for this product."
      ],
      "status": "current",
      "evidenceLevel": "test_report",
      "checked": "2026-10-15"
    },
    {
      "id": "newmor-project-paper-backed-380",
      "sourceUrl": "https://www.mrwallcover.com/advice/wallcovering-fire-ratings-uk/#product-newmor-project-paper-backed-380",
      "manufacturer": "Newmor",
      "product": "Project paper-backed vinyl, 380 g/m²",
      "reference": "Classification report 314369 issue 1 (May 2012)",
      "scope": "The Project range paper-backed vinyl as tested.",
      "construction": "PVC coating 290 g/m² on paper backing 90 g/m², 0.55 mm",
      "weight": "380 g/m² (396 g/m² measured)",
      "classificationRaw": "B – s2, d0",
      "notation": "B – s2, d0",
      "classification": {
        "class": "B",
        "smoke": "s2",
        "droplets": "d0"
      },
      "reading": "B-s2,d0",
      "classificationStandardCited": "EN 13501-1:2007+A1:2009",
      "evidence": [
        {
          "sourceId": "src-newmor-exova-314369",
          "evidenceType": "classification_report",
          "label": "Classification report",
          "documentReference": "314369 issue 1",
          "testBody": "Exova Warringtonfire (notified body 0833)"
        }
      ],
      "testedBuildup": {
        "substrate": "Fibre-cement board, 8 mm, 1,800 kg/m³, primed with a PVA and starch sealer at 85 g/m²",
        "adhesive": "A PVA and starch paste at 200 g/m² (the report names two different grades on different pages)",
        "other": null
      },
      "fieldOfApplication": "Substrates of at least 1,800 kg/m³, at least 8 mm thick, A2 or better, excluding paper-faced plasterboard; primed with ET Primaseal at 85 g/m² and hung with Dixon Turner Heavy at 200 g/m² (as the field of application states); no variation in thickness, weight, composition or construction.",
      "limitations": [
        "Paper-faced plasterboard is expressly excluded.",
        "The report dates from 2012 and cites the 2007+A1:2009 edition of EN 13501-1; it is not invalid for that reason alone, but ask Newmor whether it remains the current evidence."
      ],
      "gaps": [
        {
          "kind": "conflict",
          "text": "The report names a Light grade of adhesive in the product description and a Heavy grade in the field of application."
        }
      ],
      "conflicts": [
        "The report names a Light grade of adhesive in the product description and a Heavy grade in the field of application."
      ],
      "unresolved": [],
      "status": "current",
      "evidenceLevel": "classification_report",
      "checked": "2026-10-15"
    }
  ],
  "sourcesIntroduction": "Every document cited on this page, grouped by where it comes from. For standards we link the publisher's catalogue record, which confirms the title and edition; we have not reproduced paid standards. For manufacturers we link their own published documents rather than copying them. The checking date is when we last opened each source.",
  "sources": [
    {
      "id": "src-gov-adb-landing",
      "issuer": "Ministry of Housing, Communities and Local Government",
      "title": "Fire safety: Approved Document B (GOV.UK collection)",
      "reference": null,
      "type": "government_guidance",
      "group": "england",
      "issued": "16 September 2026 (page last updated)",
      "effective": null,
      "statedExpiry": null,
      "url": "https://www.gov.uk/government/publications/fire-safety-approved-document-b",
      "accessed": "2026-10-15",
      "establishes": "GOV.UK's index of the current Approved Document B volumes and amendment booklets, with the change history.",
      "limits": null,
      "status": "current"
    },
    {
      "id": "src-adb2-2026-consolidated",
      "issuer": "Ministry of Housing, Communities and Local Government",
      "title": "Approved Document B: Fire safety, Volume 2: Buildings other than dwellings",
      "reference": "2019 edition incorporating the 2020, 2022, 2025 and 2026 amendments, with the forthcoming 2029 changes; for use in England",
      "type": "government_guidance",
      "group": "england",
      "issued": "16 September 2026 (GOV.UK listing updated)",
      "effective": null,
      "statedExpiry": null,
      "url": "https://assets.publishing.service.gov.uk/media/6aa3bb7492e72b8ac437f145/AD_B2_2026.pdf",
      "accessed": "2026-10-15",
      "establishes": "England's current guidance on wall and ceiling linings in buildings other than dwellings: requirement B2, Section 6, Table 6.1 and its BS EN 15102 wallcovering note, the definitions of walls and ceilings, and Appendix B on reaction-to-fire classes, test evidence and substrates.",
      "limits": "Guidance on one way of meeting requirement B2, not the law itself. Pages marked as 2029 amendments are not yet in force.",
      "status": "current"
    },
    {
      "id": "src-adb1-2026-consolidated",
      "issuer": "Ministry of Housing, Communities and Local Government",
      "title": "Approved Document B: Fire safety, Volume 1: Dwellings",
      "reference": "2019 edition incorporating the 2020, 2022, 2025 and 2026 amendments, with the forthcoming 2029 changes; for use in England",
      "type": "government_guidance",
      "group": "england",
      "issued": "16 September 2026 (GOV.UK listing updated)",
      "effective": null,
      "statedExpiry": null,
      "url": "https://assets.publishing.service.gov.uk/media/6aa3bb335f6e942efe37f150/AD_B1_2026.pdf",
      "accessed": "2026-10-15",
      "establishes": "Volume 1 covers dwellings, including blocks of flats. Its Table 4.1 sets B-s3,d2 for other circulation spaces, including the common areas of blocks of flats, with the same BS EN 15102 wallcovering note as Volume 2; C-s3,d2 for other rooms and circulation spaces within a dwelling; and D-s3,d2 for small rooms and dwellinghouse garages.",
      "limits": "Guidance for England only. The rows for rooms within a dwelling are not the same as Volume 2.",
      "status": "current"
    },
    {
      "id": "src-adb2-2022-edition",
      "issuer": "Ministry of Housing, Communities and Local Government",
      "title": "Approved Document B: Fire safety, Volume 2, 2019 edition incorporating the 2020 amendments and the 2022 amendments (superseded)",
      "reference": "Superseded edition",
      "type": "government_guidance",
      "group": "england",
      "issued": "2022",
      "effective": null,
      "statedExpiry": null,
      "url": "https://assets.publishing.service.gov.uk/media/67d02361d5ec5ed9e09f5f07/Approved_Document_B__fire_safety__volume_2_-_Buildings_other_than_dwellings__2019_edition_incorporating_2020_and_2022_amendments.pdf",
      "accessed": "2026-10-15",
      "establishes": "The previous edition, which still applies to work covered by the transitional arrangements. Its Appendix B and Table B1 set out the former national classes and warn that national and European classes do not automatically equate.",
      "limits": null,
      "status": "superseded"
    },
    {
      "id": "src-adb-2025-amendments",
      "issuer": "Ministry of Housing, Communities and Local Government",
      "title": "Amendments to Approved Document B, Volumes 1 and 2: taking effect on 2 March 2025",
      "reference": "2025 amendments booklet",
      "type": "government_guidance",
      "group": "england",
      "issued": "Published September 2024; corrected 2 March 2025",
      "effective": "2025-03-02",
      "statedExpiry": null,
      "url": "https://assets.publishing.service.gov.uk/media/67c1ac3d16dc9038974dbcfe/2025_Amendments_to_Approved_Document_B_volume_1_and_volume_2.pdf",
      "accessed": "2026-10-15",
      "establishes": "The removal of national reaction-to-fire classes from England's guidance from 2 March 2025, and the transitional arrangements for work already notified.",
      "limits": null,
      "status": "current"
    },
    {
      "id": "src-adb-2026-amendments",
      "issuer": "Ministry of Housing, Communities and Local Government",
      "title": "Amendments to Approved Document B, Volumes 1 and 2: taking effect on 30 September 2026",
      "reference": "2026 amendments booklet",
      "type": "government_guidance",
      "group": "england",
      "issued": "First published March 2024; updated September 2024",
      "effective": "2026-09-30",
      "statedExpiry": null,
      "url": "https://assets.publishing.service.gov.uk/media/66d57a94d107658faec7e448/AD_B_2026_amendments.pdf",
      "accessed": "2026-10-15",
      "establishes": "The 2026 changes (second staircases and evacuation lifts in blocks of flats), in force from 30 September 2026. They do not change lining classes.",
      "limits": null,
      "status": "current"
    },
    {
      "id": "src-adb-2029-amendments",
      "issuer": "Ministry of Housing, Communities and Local Government",
      "title": "Amendments to Approved Document B, Volumes 1 and 2: taking effect on 2 September 2029",
      "reference": "2029 amendments booklet",
      "type": "government_guidance",
      "group": "england",
      "issued": "September 2024",
      "effective": "2029-09-02",
      "statedExpiry": null,
      "url": "https://assets.publishing.service.gov.uk/media/66d57aaabdecebe01a18341b/AD_B_2029_amendments.pdf",
      "accessed": "2026-10-15",
      "establishes": "The removal of national fire-resistance classes from England's guidance on 2 September 2029, with transitional arrangements.",
      "limits": "Not in force on the date we checked.",
      "status": "forthcoming"
    },
    {
      "id": "src-mhclg-circular-letter-2024",
      "issuer": "Ministry of Housing, Communities and Local Government",
      "title": "Approved Document B (fire safety): new updates to support enhanced fire safety",
      "reference": "Letter accompanying Circulars 03/2024, 04/2024 and 05/2024",
      "type": "government_guidance",
      "group": "england",
      "issued": "2 September 2024",
      "effective": null,
      "statedExpiry": null,
      "url": "https://www.gov.uk/government/publications/amendments-to-approved-document-b-fire-safety-circular-and-letter/approved-document-b-fire-safety-new-updates-to-support-enhanced-fire-safety",
      "accessed": "2026-10-15",
      "establishes": "The government's own explanation of the 2025, 2026 and 2029 changes, treating reaction to fire and fire resistance as separate subjects.",
      "limits": null,
      "status": "current"
    },
    {
      "id": "src-circular-03-2024",
      "issuer": "Ministry of Housing, Communities and Local Government",
      "title": "Circular 03/2024: Approved Document B (sprinklers and reaction to fire)",
      "reference": "Circular 03/2024, 5 pp",
      "type": "government_guidance",
      "group": "england",
      "issued": "2 September 2024",
      "effective": "2025-03-02",
      "statedExpiry": null,
      "url": "https://assets.publishing.service.gov.uk/media/66d5c0219084b18b95709ec4/Circular_032024_Sprinklers_and_Reaction_to_fire.pdf",
      "accessed": "2026-10-15",
      "establishes": "The circular approving the 2025 amendments, including the removal of the national classification for reaction to fire.",
      "limits": null,
      "status": "current"
    },
    {
      "id": "src-circular-05-2024",
      "issuer": "Ministry of Housing, Communities and Local Government",
      "title": "Circular 05/2024: Approved Document B (fire resistance)",
      "reference": "Circular 05/2024, 5 pp",
      "type": "government_guidance",
      "group": "england",
      "issued": "2 September 2024",
      "effective": "2029-09-02",
      "statedExpiry": null,
      "url": "https://assets.publishing.service.gov.uk/media/66d5c09e6eb664e57141db15/Circular_052024_Fire_resistance.pdf",
      "accessed": "2026-10-15",
      "establishes": "The circular approving the 2029 amendments on the national classification for fire resistance.",
      "limits": "Not in force on the date we checked.",
      "status": "forthcoming"
    },
    {
      "id": "src-gov-adb-faq",
      "issuer": "Ministry of Housing, Communities and Local Government",
      "title": "Approved Document B: fire safety, frequently asked questions",
      "reference": "Question 18 (field of application of reaction-to-fire classes)",
      "type": "government_guidance",
      "group": "england",
      "issued": "21 February 2025 (page last updated)",
      "effective": null,
      "statedExpiry": null,
      "url": "https://www.gov.uk/guidance/approved-document-b-fire-safety-frequently-asked-questions",
      "accessed": "2026-10-15",
      "establishes": "Official answers on Approved Document B, including that the same material can achieve different classes in different forms, fixings and substrates, and that variations should be assessed by competent professionals.",
      "limits": null,
      "status": "current"
    },
    {
      "id": "src-leg-br2010",
      "issuer": "legislation.gov.uk",
      "title": "The Building Regulations 2010, Schedule 1, Part B, and regulation 7",
      "reference": "SI 2010/2214",
      "type": "legislation",
      "group": "england",
      "issued": null,
      "effective": null,
      "statedExpiry": null,
      "url": "https://www.legislation.gov.uk/uksi/2010/2214/schedule/1",
      "accessed": "2026-10-15",
      "establishes": "The legal requirement for internal linings (requirement B2 in Schedule 1 to the Building Regulations 2010) and regulation 7 on materials.",
      "limits": null,
      "status": "current"
    },
    {
      "id": "src-leg-br2010-reg3",
      "issuer": "legislation.gov.uk",
      "title": "The Building Regulations 2010, regulation 3 (meaning of building work)",
      "reference": "SI 2010/2214",
      "type": "legislation",
      "group": "england",
      "issued": null,
      "effective": null,
      "statedExpiry": null,
      "url": "https://www.legislation.gov.uk/uksi/2010/2214/regulation/3",
      "accessed": "2026-10-17",
      "establishes": "An alteration is 'material' only if it affects a 'relevant requirement': Part A, B1, B3, B4, B5, Part M or Part T. B2 (internal linings) is not on the list, so redecorating on its own is not normally building work.",
      "limits": "The text applies in England; Wales has its own amendments to the same regulations (the Welsh Volume 2, paragraph 0.18, gives the same list for Part B).",
      "status": "current"
    },
    {
      "id": "src-leg-ba1984-s6-s7",
      "issuer": "legislation.gov.uk",
      "title": "Building Act 1984, sections 6 and 7",
      "reference": "1984 c. 55",
      "type": "legislation",
      "group": "england",
      "issued": null,
      "effective": null,
      "statedExpiry": null,
      "url": "https://www.legislation.gov.uk/ukpga/1984/55/section/7",
      "accessed": "2026-10-15",
      "establishes": "The status of approved documents: approved under section 6, and under section 7 compliance or non-compliance may be relied on as tending to establish or negative liability.",
      "limits": null,
      "status": "current"
    },
    {
      "id": "src-leg-rrfso2005",
      "issuer": "legislation.gov.uk",
      "title": "Regulatory Reform (Fire Safety) Order 2005, articles 3, 8, 9 and 50",
      "reference": "SI 2005/1541",
      "type": "legislation",
      "group": "england",
      "issued": null,
      "effective": null,
      "statedExpiry": null,
      "url": "https://www.legislation.gov.uk/uksi/2005/1541/article/9",
      "accessed": "2026-10-15",
      "establishes": "Fire safety in buildings in use in England and Wales, other than inside private homes: the responsible person's duties to take general fire precautions and to keep a fire risk assessment under review, including after significant changes, extensions or conversions (article 9(3)).",
      "limits": null,
      "status": "current"
    },
    {
      "id": "src-leg-rrfso2005-art2",
      "issuer": "legislation.gov.uk",
      "title": "Regulatory Reform (Fire Safety) Order 2005, article 2 (interpretation)",
      "reference": "SI 2005/1541",
      "type": "legislation",
      "group": "england",
      "issued": null,
      "effective": null,
      "statedExpiry": null,
      "url": "https://www.legislation.gov.uk/uksi/2005/1541/article/2",
      "accessed": "2026-10-17",
      "establishes": "'Domestic premises' means premises occupied as a private dwelling, including appurtenances not used in common by the occupants of more than one dwelling; shared halls and stairs are therefore not domestic premises.",
      "limits": null,
      "status": "current"
    },
    {
      "id": "src-leg-rrfso2005-art3",
      "issuer": "legislation.gov.uk",
      "title": "Regulatory Reform (Fire Safety) Order 2005, article 3 (meaning of \"responsible person\")",
      "reference": "SI 2005/1541",
      "type": "legislation",
      "group": "england",
      "issued": null,
      "effective": null,
      "statedExpiry": null,
      "url": "https://www.legislation.gov.uk/uksi/2005/1541/article/3",
      "accessed": "2026-10-17",
      "establishes": "The responsible person is the employer, for a workplace to any extent under its control; otherwise the person who controls the premises for a trade, business or other undertaking; or else the owner.",
      "limits": null,
      "status": "current"
    },
    {
      "id": "src-leg-rrfso2005-art5",
      "issuer": "legislation.gov.uk",
      "title": "Regulatory Reform (Fire Safety) Order 2005, article 5 (duties under the Order)",
      "reference": "SI 2005/1541",
      "type": "legislation",
      "group": "england",
      "issued": null,
      "effective": null,
      "statedExpiry": null,
      "url": "https://www.legislation.gov.uk/uksi/2005/1541/article/5",
      "accessed": "2026-10-17",
      "establishes": "Anyone else with control of the premises to any extent shares the duties for matters within their control, including anyone whose contract or tenancy gives them an obligation for maintenance, repair or safety.",
      "limits": null,
      "status": "current"
    },
    {
      "id": "src-leg-rrfso2005-art6",
      "issuer": "legislation.gov.uk",
      "title": "Regulatory Reform (Fire Safety) Order 2005, article 6 (application to premises)",
      "reference": "SI 2005/1541",
      "type": "legislation",
      "group": "england",
      "issued": null,
      "effective": null,
      "statedExpiry": null,
      "url": "https://www.legislation.gov.uk/uksi/2005/1541/article/6",
      "accessed": "2026-10-17",
      "establishes": "The Order does not apply to domestic premises (article 6(1)(a)); in a building with two or more sets of domestic premises it applies to the structure, external walls (including doors, windows and balconies) and common parts, and to the doors between the flats and the common parts (article 6(1A) and (1B), inserted by the Fire Safety Act 2021).",
      "limits": null,
      "status": "current"
    },
    {
      "id": "src-leg-fsa2021-s1",
      "issuer": "legislation.gov.uk",
      "title": "Fire Safety Act 2021, section 1",
      "reference": "2021 c. 24",
      "type": "legislation",
      "group": "england",
      "issued": null,
      "effective": null,
      "statedExpiry": null,
      "url": "https://www.legislation.gov.uk/ukpga/2021/24/section/1",
      "accessed": "2026-10-17",
      "establishes": "Inserts article 6(1A) and (1B) into the Fire Safety Order: in a building with two or more sets of domestic premises, the Order covers the structure, external walls (including doors, windows and balconies) and common parts, and the doors between the flats and the common parts. In force in Wales from 1 October 2021 and in England from 16 May 2022.",
      "limits": "Applies to England and Wales only.",
      "status": "current"
    },
    {
      "id": "src-fsra-sleeping",
      "issuer": "Department for Communities and Local Government",
      "title": "Fire safety risk assessment: sleeping accommodation",
      "reference": "Guide published under article 50 of the Fire Safety Order",
      "type": "government_guidance",
      "group": "england",
      "issued": "2006 (reprinted 2015)",
      "effective": null,
      "statedExpiry": null,
      "url": "https://assets.publishing.service.gov.uk/media/6662d2fafe8be9a012ca94cb/9281_Sleeping_Accomodation_v2.pdf",
      "accessed": "2026-10-15",
      "establishes": "Official fire risk assessment guidance for hotels and other sleeping accommodation in England and Wales. It discusses wall and ceiling linings and says care is needed with multi-layer decorative systems such as wallpapers and oil-based paints, in the older national class terms.",
      "limits": "Written before the European classes replaced the national ones in English guidance; it says the European equivalent is acceptable.",
      "status": "current"
    },
    {
      "id": "src-fsra-offices-shops",
      "issuer": "Department for Communities and Local Government",
      "title": "Fire safety risk assessment: offices and shops",
      "reference": "Guide published under article 50 of the Fire Safety Order",
      "type": "government_guidance",
      "group": "england",
      "issued": "2006 (reprinted 2015)",
      "effective": null,
      "statedExpiry": null,
      "url": "https://assets.publishing.service.gov.uk/media/5a815c78ed915d74e33fdc7e/9449_Offices_and_Shops_v2.pdf",
      "accessed": "2026-10-15",
      "establishes": "The equivalent official guidance for offices and shops. It lists wall and ceiling linings by the older national classes and notes that additional finishes may harm a surface's fire performance.",
      "limits": "Uses the older national class terms.",
      "status": "current"
    },
    {
      "id": "src-wales-adb-page",
      "issuer": "Welsh Government",
      "title": "Approved Document B: fire safety (Wales)",
      "reference": null,
      "type": "webpage",
      "group": "wales",
      "issued": "19 June 2025 (page last updated)",
      "effective": null,
      "statedExpiry": null,
      "url": "https://www.gov.wales/approved-document-b-fire-safety",
      "accessed": "2026-10-15",
      "establishes": "The Welsh Government's index of Approved Document B for use in Wales and its amendment slips.",
      "limits": null,
      "status": "current"
    },
    {
      "id": "src-wales-adb-vol2",
      "issuer": "Welsh Government",
      "title": "Approved Document B, Volume 2: Buildings other than dwellinghouses (for use in Wales)",
      "reference": "2006 edition incorporating the 2010, 2013, 2016, 2017 and 2020 amendments",
      "type": "government_guidance",
      "group": "wales",
      "issued": "December 2021 (2020 amendments in force 31 December 2020)",
      "effective": "2020-12-31",
      "statedExpiry": null,
      "url": "https://www.gov.wales/sites/default/files/publications/2021-12/building-regulations-guidance-part-b-fire-safety-volume-2-buildings-other-than-dwellinghouses.pdf",
      "accessed": "2026-10-15",
      "establishes": "Wales's guidance on wall and ceiling linings: Table 10 with national and European classes, its BS EN 15102 wallcovering note, and Appendix A's definition of Class 0.",
      "limits": null,
      "status": "current"
    },
    {
      "id": "src-wales-adb-vol1",
      "issuer": "Welsh Government",
      "title": "Approved Document B, Volume 1: Dwellinghouses (for use in Wales)",
      "reference": "2006 edition incorporating the 2010, 2016 and 2020 amendments",
      "type": "government_guidance",
      "group": "wales",
      "issued": "August 2026 (file published)",
      "effective": null,
      "statedExpiry": null,
      "url": "https://www.gov.wales/sites/default/files/publications/2026-08/building-regulations-guidance-part-b-fire-safety-volume-1-dwellinghouses.pdf",
      "accessed": "2026-10-17",
      "establishes": "The Welsh guidance for dwellinghouses, with its own edition label: 2006 edition incorporating the 2010, 2016 and 2020 amendments.",
      "limits": "Its linings table is not reproduced on the page.",
      "status": "current"
    },
    {
      "id": "src-wales-slip-2025",
      "issuer": "Welsh Government",
      "title": "Amendments to Approved Document B, Volumes 1 and 2, coming into effect 20 December 2025 (Wales)",
      "reference": "13 pp; WG52486",
      "type": "government_guidance",
      "group": "wales",
      "issued": "19 June 2025",
      "effective": "2025-12-20",
      "statedExpiry": null,
      "url": "https://www.gov.wales/sites/default/files/publications/2025-06/amendments-to-approved-document-B-fire-safety-volume-1-and-volume-2.pdf",
      "accessed": "2026-10-15",
      "establishes": "The Welsh amendment slip in force from 20 December 2025. It replaces the external-wall guidance (Volume 1 paras 9.5-9.6; Volume 2 Section 13), replaces Appendix A Table A7 item 8, and adds wayfinding signage, evacuation alert systems and secure information boxes for blocks of flats (Volume 2 paras 18.16-18.24). It does not amend Section 7 or Table 10.",
      "limits": null,
      "status": "current"
    },
    {
      "id": "src-wales-wgc-004-2025",
      "issuer": "Welsh Government",
      "title": "Building (Amendment) (Wales) Regulations 2025: circular WGC 004/2025",
      "reference": "WGC 004/2025; SI 2025/704 (W.119)",
      "type": "government_guidance",
      "group": "wales",
      "issued": "19 June 2025",
      "effective": "2025-12-20",
      "statedExpiry": null,
      "url": "https://www.gov.wales/building-amendment-wales-regulations-2025-wgc-0042025-html",
      "accessed": "2026-10-15",
      "establishes": "The Welsh circular on the 2025 amendments. It says the proposed move of national classes into an appendix will follow the next revision of Approved Document B.",
      "limits": null,
      "status": "current"
    },
    {
      "id": "src-wales-partb-summary",
      "issuer": "Welsh Government",
      "title": "Part B (fire safety): summary of responses and Government response",
      "reference": "WG50772; 24 pp",
      "type": "government_guidance",
      "group": "wales",
      "issued": "8 January 2025",
      "effective": null,
      "statedExpiry": null,
      "url": "https://www.gov.wales/sites/default/files/consultations/2025-01/part%20b-fire-safety-of-the-building-regulations-summary-of-responses.pdf",
      "accessed": "2026-10-15",
      "establishes": "The Welsh Government's consultation response: national classes are to move to an appendix rather than be deleted, and full removal would need further research and consultation.",
      "limits": null,
      "status": "current"
    },
    {
      "id": "src-leg-wsi-2025-1320",
      "issuer": "legislation.gov.uk",
      "title": "The Building etc. (Amendment) (No. 2) (Wales) Regulations 2025",
      "reference": "SI 2025/1320 (W.)",
      "type": "legislation",
      "group": "wales",
      "issued": null,
      "effective": "2026-07-01",
      "statedExpiry": null,
      "url": "https://www.legislation.gov.uk/wsi/2025/1320/contents",
      "accessed": "2026-10-17",
      "establishes": "Adds dutyholder and competence duties for building work in Wales (Part 2B of the Building Regulations 2010 as they apply in Wales) and a regulation 38 acknowledgement, from 1 July 2026, with transitional provisions for work already started or notified.",
      "limits": "Changes procedures and duties, not the lining classes.",
      "status": "current"
    },
    {
      "id": "src-leg-wsi-2025-1321",
      "issuer": "legislation.gov.uk",
      "title": "The Building (Higher-Risk Buildings Procedures) (Wales) Regulations 2025",
      "reference": "SI 2025/1321 (W.)",
      "type": "legislation",
      "group": "wales",
      "issued": null,
      "effective": "2026-07-01",
      "statedExpiry": null,
      "url": "https://www.legislation.gov.uk/wsi/2025/1321/contents",
      "accessed": "2026-10-17",
      "establishes": "The building control procedure for higher-risk buildings in Wales, in force from 1 July 2026.",
      "limits": null,
      "status": "current"
    },
    {
      "id": "src-leg-wsi-2023-1210",
      "issuer": "legislation.gov.uk",
      "title": "The Building Safety (Description of Higher-Risk Building) (Design and Construction Phase) (Wales) Regulations 2023",
      "reference": "SI 2023/1210 (W.)",
      "type": "legislation",
      "group": "wales",
      "issued": null,
      "effective": null,
      "statedExpiry": null,
      "url": "https://www.legislation.gov.uk/wsi/2023/1210/regulation/3",
      "accessed": "2026-10-17",
      "establishes": "In Wales, a higher-risk building for design and construction is at least 18 m or seven storeys and contains at least one residential unit, a hospital with an overnight bed, a care home or a children's home (regulation 3); a building comprised entirely of a hotel is excluded (regulation 6).",
      "limits": null,
      "status": "current"
    },
    {
      "id": "src-scot-collection",
      "issuer": "Scottish Government",
      "title": "Building standards (collection)",
      "reference": null,
      "type": "webpage",
      "group": "scotland",
      "issued": null,
      "effective": null,
      "statedExpiry": null,
      "url": "https://www.gov.scot/collections/building-standards/",
      "accessed": "2026-10-15",
      "establishes": "The Scottish Government's index of the building standards technical handbooks and the dates they apply from.",
      "limits": null,
      "status": "current"
    },
    {
      "id": "src-scot-nd-apr2026-page",
      "issuer": "Scottish Government",
      "title": "Building standards technical handbook: non-domestic, April 2026",
      "reference": null,
      "type": "government_guidance",
      "group": "scotland",
      "issued": "9 March 2026 (published)",
      "effective": "2026-04-06",
      "statedExpiry": null,
      "url": "https://www.gov.scot/publications/building-standards-technical-handbook-non-domestic-april-2026-pdf/",
      "accessed": "2026-10-15",
      "establishes": "The current non-domestic handbook, for building warrants submitted on or after 6 April 2026. Standard 2.5 and Table 2.4 cover internal linings; clause 2.5.1 leaves decorative wallpaper and paint out of the classified surface.",
      "limits": null,
      "status": "current"
    },
    {
      "id": "src-scot-dom-apr2026-page",
      "issuer": "Scottish Government",
      "title": "Building standards technical handbook: domestic, April 2026",
      "reference": null,
      "type": "government_guidance",
      "group": "scotland",
      "issued": "9 March 2026 (published)",
      "effective": "2026-04-06",
      "statedExpiry": null,
      "url": "https://www.gov.scot/publications/building-standards-technical-handbook-domestic-april-2026-pdf/",
      "accessed": "2026-10-17",
      "establishes": "Clause 2.5.1 of the domestic handbook: wall and ceiling surfaces mean the substrate or lining material and exclude decorative wallpaper and paints, which are not controlled by the guidance; multiple layers are not recommended when redecorating. Protected zones A1, A2 or B; rooms, unprotected zones and protected enclosures no worse than C; small rooms and limited wall areas D.",
      "limits": "The hash is of the publication page; the PDF linked from it was read.",
      "status": "current"
    },
    {
      "id": "src-scot-nd-2022-html",
      "issuer": "Scottish Government",
      "title": "Building standards technical handbook 2022: non-domestic, section 2.5 Internal linings",
      "reference": null,
      "type": "government_guidance",
      "group": "scotland",
      "issued": "2022",
      "effective": null,
      "statedExpiry": null,
      "url": "https://www.gov.scot/publications/building-standards-technical-handbook-2022-non-domestic/2-fire/2-5-internal-linings/",
      "accessed": "2026-10-15",
      "establishes": "The 2022 handbook's section 2.5, showing that the wallpaper exclusion and Table 2.4 were the same before the 2026 edition.",
      "limits": null,
      "status": "superseded"
    },
    {
      "id": "src-leg-bsr-scotland-2004",
      "issuer": "legislation.gov.uk",
      "title": "The Building (Scotland) Regulations 2004",
      "reference": "SSI 2004/406",
      "type": "legislation",
      "group": "scotland",
      "issued": null,
      "effective": null,
      "statedExpiry": null,
      "url": "https://www.legislation.gov.uk/ssi/2004/406/contents",
      "accessed": "2026-10-15",
      "establishes": "The Scottish building regulations, whose Schedule 5 contains the standards the handbooks give guidance on.",
      "limits": null,
      "status": "current"
    },
    {
      "id": "src-leg-fire-scotland-s78",
      "issuer": "legislation.gov.uk",
      "title": "Fire (Scotland) Act 2005, section 78",
      "reference": "2005 asp 5",
      "type": "legislation",
      "group": "scotland",
      "issued": null,
      "effective": null,
      "statedExpiry": null,
      "url": "https://www.legislation.gov.uk/asp/2005/5/section/78",
      "accessed": "2026-10-17",
      "establishes": "The Part 3 fire safety duties do not apply to domestic premises, which include a stair or passage used in common by the occupants of more than one dwelling; houses that must be licensed as houses in multiple occupation are not domestic premises, so the duties apply to them.",
      "limits": null,
      "status": "current"
    },
    {
      "id": "src-leg-fire-scotland-s53",
      "issuer": "legislation.gov.uk",
      "title": "Fire (Scotland) Act 2005, section 53 (duties of employers)",
      "reference": "2005 asp 5",
      "type": "legislation",
      "group": "scotland",
      "issued": null,
      "effective": null,
      "statedExpiry": null,
      "url": "https://www.legislation.gov.uk/asp/2005/5/section/53",
      "accessed": "2026-10-17",
      "establishes": "Each employer must assess the workplace for fire risks and take fire-safety measures.",
      "limits": null,
      "status": "current"
    },
    {
      "id": "src-leg-fire-scotland-s54",
      "issuer": "legislation.gov.uk",
      "title": "Fire (Scotland) Act 2005, section 54 (duties in relation to relevant premises)",
      "reference": "2005 asp 5",
      "type": "legislation",
      "group": "scotland",
      "issued": null,
      "effective": null,
      "statedExpiry": null,
      "url": "https://www.legislation.gov.uk/asp/2005/5/section/54",
      "accessed": "2026-10-17",
      "establishes": "Anyone with control of relevant premises to any extent must assess fire risks and take fire-safety measures to that extent; in some cases the owner; and anyone whose contract or tenancy gives them an obligation for maintenance, repair or fire safety.",
      "limits": null,
      "status": "current"
    },
    {
      "id": "src-leg-fs-scotland-regs-2006-r24",
      "issuer": "legislation.gov.uk",
      "title": "Fire Safety (Scotland) Regulations 2006, regulation 24",
      "reference": "SSI 2006/456",
      "type": "legislation",
      "group": "scotland",
      "issued": null,
      "effective": null,
      "statedExpiry": null,
      "url": "https://www.legislation.gov.uk/ssi/2006/456/regulation/24",
      "accessed": "2026-10-17",
      "establishes": "Applies the duty to maintain measures provided for the protection of firefighters (regulation 23) to the common areas of private dwellings, for persons with control of those areas.",
      "limits": null,
      "status": "current"
    },
    {
      "id": "src-leg-bsr-scotland-2004-r5",
      "issuer": "legislation.gov.uk",
      "title": "Building (Scotland) Regulations 2004, regulation 5 (building warrant exemptions)",
      "reference": "SSI 2004/406",
      "type": "legislation",
      "group": "scotland",
      "issued": null,
      "effective": null,
      "statedExpiry": null,
      "url": "https://www.legislation.gov.uk/ssi/2004/406/regulation/5",
      "accessed": "2026-10-17",
      "establishes": "Work of a kind listed in schedule 3 must meet the standards but does not need a building warrant, subject to the exceptions and conditions.",
      "limits": null,
      "status": "current"
    },
    {
      "id": "src-leg-bsr-scotland-2004-sch3",
      "issuer": "legislation.gov.uk",
      "title": "Building (Scotland) Regulations 2004, schedule 3 (work not requiring a warrant)",
      "reference": "SSI 2004/406",
      "type": "legislation",
      "group": "scotland",
      "issued": null,
      "effective": null,
      "statedExpiry": null,
      "url": "https://www.legislation.gov.uk/ssi/2004/406/schedule/3",
      "accessed": "2026-10-17",
      "establishes": "Replacing flooring, lining, covering or rendering, in whole or in part, by material of the same general type, internally or externally, needs no building warrant, on condition that the work is to a standard no worse than at present.",
      "limits": null,
      "status": "current"
    },
    {
      "id": "src-ni-tbe-page",
      "issuer": "Department of Finance (Northern Ireland)",
      "title": "Technical Booklet E",
      "reference": null,
      "type": "webpage",
      "group": "northern-ireland",
      "issued": null,
      "effective": null,
      "statedExpiry": null,
      "url": "https://www.finance-ni.gov.uk/publications/technical-booklet-e",
      "accessed": "2026-10-15",
      "establishes": "The Department of Finance's page for Technical Booklet E and its amendments.",
      "limits": null,
      "status": "current"
    },
    {
      "id": "src-ni-tbe-2012",
      "issuer": "Department of Finance and Personnel (Northern Ireland)",
      "title": "Technical Booklet E: Fire safety",
      "reference": "October 2012",
      "type": "government_guidance",
      "group": "northern-ireland",
      "issued": "October 2012",
      "effective": "2012-10-31",
      "statedExpiry": null,
      "url": "https://www.finance-ni.gov.uk/sites/default/files/2025-05/Technical-booklet-E-Fire-Safety-October-2012_0.pdf",
      "accessed": "2026-10-15",
      "establishes": "Northern Ireland's fire safety guidance as published in 2012, including Table 3.1 with national and European classes for walls and ceilings.",
      "limits": null,
      "status": "current"
    },
    {
      "id": "src-ni-tbe-trackchanges",
      "issuer": "Department of Finance (Northern Ireland)",
      "title": "Technical Booklet E (Fire safety): 2012 edition with amendments incorporated (track-changes version)",
      "reference": "Not an up-to-date consolidated version, as the Department notes",
      "type": "government_guidance",
      "group": "northern-ireland",
      "issued": "November 2024",
      "effective": null,
      "statedExpiry": null,
      "url": "https://www.finance-ni.gov.uk/sites/default/files/2024-11/Track%20changes%20TBE%20for%20publication%20-%20Final_3.pdf",
      "accessed": "2026-10-15",
      "establishes": "The booklet with the 2022 (AMD 7) and 2024 (AMD 9, in force 6 May 2025) amendments shown, confirming Table 3.1 is unchanged and has no BS EN 15102 wallcovering note. The Department says it is not an up-to-date consolidated version.",
      "limits": null,
      "status": "current"
    },
    {
      "id": "src-ni-amd7",
      "issuer": "Department of Finance (Northern Ireland)",
      "title": "Amendments booklet AMD 7 (Technical Booklets B, C and E)",
      "reference": "AMD 7",
      "type": "government_guidance",
      "group": "northern-ireland",
      "issued": "April 2022",
      "effective": "2022-04-01",
      "statedExpiry": null,
      "url": "https://www.finance-ni.gov.uk/sites/default/files/2025-05/AMD%207%20final.pdf",
      "accessed": "2026-10-15",
      "establishes": "Amendment booklet AMD 7, in force from 1 April 2022. No change to the linings table was found.",
      "limits": null,
      "status": "current"
    },
    {
      "id": "src-ni-amd9",
      "issuer": "Department of Finance (Northern Ireland)",
      "title": "Amendments booklet AMD 9 (Technical Booklets E and R)",
      "reference": "AMD 9",
      "type": "government_guidance",
      "group": "northern-ireland",
      "issued": "May 2025",
      "effective": "2025-05-06",
      "statedExpiry": null,
      "url": "https://www.finance-ni.gov.uk/sites/default/files/2025-05/AMD%209%20for%20publication%20-%20Final%20-May%2025_1.pdf",
      "accessed": "2026-10-15",
      "establishes": "Amendment booklet AMD 9, in force from 6 May 2025. No change to the linings table was found.",
      "limits": null,
      "status": "current"
    },
    {
      "id": "src-leg-ni-fire-order-art50",
      "issuer": "legislation.gov.uk",
      "title": "Fire and Rescue Services (Northern Ireland) Order 2006, article 50",
      "reference": "SI 2006/1254 (N.I. 9)",
      "type": "legislation",
      "group": "northern-ireland",
      "issued": null,
      "effective": null,
      "statedExpiry": null,
      "url": "https://www.legislation.gov.uk/nisi/2006/1254/article/50",
      "accessed": "2026-10-17",
      "establishes": "The fire-safety duties apply to 'relevant premises', which exclude domestic premises. Domestic premises include a stair or passage shared by the occupants of more than one dwelling. A house in multiple occupation is not domestic premises, so the duties apply to it.",
      "limits": null,
      "status": "current"
    },
    {
      "id": "src-leg-ni-fire-order-art25",
      "issuer": "legislation.gov.uk",
      "title": "Fire and Rescue Services (Northern Ireland) Order 2006, article 25 (duties of employers)",
      "reference": "SI 2006/1254 (N.I. 9)",
      "type": "legislation",
      "group": "northern-ireland",
      "issued": null,
      "effective": null,
      "statedExpiry": null,
      "url": "https://www.legislation.gov.uk/nisi/2006/1254/article/25",
      "accessed": "2026-10-17",
      "establishes": "Each employer must assess the workplace for fire risks and take fire-safety measures.",
      "limits": null,
      "status": "current"
    },
    {
      "id": "src-leg-ni-fire-order-art26",
      "issuer": "legislation.gov.uk",
      "title": "Fire and Rescue Services (Northern Ireland) Order 2006, article 26 (duties in relation to relevant premises)",
      "reference": "SI 2006/1254 (N.I. 9)",
      "type": "legislation",
      "group": "northern-ireland",
      "issued": null,
      "effective": null,
      "statedExpiry": null,
      "url": "https://www.legislation.gov.uk/nisi/2006/1254/article/26",
      "accessed": "2026-10-17",
      "establishes": "Anyone with control of relevant premises to any extent, in some cases the owner, and anyone whose contract or tenancy gives them an obligation for maintenance, repair or fire safety, must assess fire risks and take fire-safety measures to that extent.",
      "limits": null,
      "status": "current"
    },
    {
      "id": "src-leg-fs-ni-regs-2010-r24",
      "issuer": "legislation.gov.uk",
      "title": "Fire Safety Regulations (Northern Ireland) 2010, regulation 24",
      "reference": "SR 2010/325",
      "type": "legislation",
      "group": "northern-ireland",
      "issued": null,
      "effective": null,
      "statedExpiry": null,
      "url": "https://www.legislation.gov.uk/nisr/2010/325/regulation/24",
      "accessed": "2026-10-17",
      "establishes": "Applies the duty to maintain measures provided for the protection of firefighters (regulation 23) to the common areas of private dwellings, for persons with control of those areas.",
      "limits": null,
      "status": "current"
    },
    {
      "id": "src-leg-br-ni-2012-r2",
      "issuer": "legislation.gov.uk",
      "title": "Building Regulations (Northern Ireland) 2012, regulation 2 (interpretation)",
      "reference": "SR 2012/192",
      "type": "legislation",
      "group": "northern-ireland",
      "issued": null,
      "effective": null,
      "statedExpiry": null,
      "url": "https://www.legislation.gov.uk/nisr/2012/192/regulation/2",
      "accessed": "2026-10-17",
      "establishes": "'Building work' includes a structural alteration, meaning any work (other than erection or a service or fitting) to which the regulations would apply if it were part of a new building.",
      "limits": null,
      "status": "current"
    },
    {
      "id": "src-leg-br-ni-2012-r34",
      "issuer": "legislation.gov.uk",
      "title": "Building Regulations (Northern Ireland) 2012, regulation 34 (internal fire spread: linings)",
      "reference": "SR 2012/192",
      "type": "legislation",
      "group": "northern-ireland",
      "issued": null,
      "effective": null,
      "statedExpiry": null,
      "url": "https://www.legislation.gov.uk/nisr/2012/192/regulation/34",
      "accessed": "2026-10-17",
      "establishes": "Internal linings must offer adequate resistance to the spread of flame over their surfaces and, in circulation spaces, have a low rate of heat release or fire growth.",
      "limits": null,
      "status": "current"
    },
    {
      "id": "src-gov-cpr-gb",
      "issuer": "Department for Business and Trade",
      "title": "Construction Products Regulation in Great Britain",
      "reference": "gov.uk detailed guide",
      "type": "government_guidance",
      "group": "gb",
      "issued": "21 May 2025 (last changed)",
      "effective": null,
      "statedExpiry": null,
      "url": "https://www.gov.uk/guidance/construction-products-regulation-in-great-britain",
      "accessed": "2026-10-15",
      "establishes": "How construction products are marked and declared in Great Britain: UKCA, and CE marking, which continues to be recognised, with a declaration of performance for products covered by a designated standard.",
      "limits": null,
      "status": "current"
    },
    {
      "id": "src-gov-cpr-ni",
      "issuer": "Department for Business and Trade",
      "title": "Construction Products Regulation in Northern Ireland",
      "reference": "gov.uk detailed guide",
      "type": "government_guidance",
      "group": "gb",
      "issued": "21 May 2025 (last changed)",
      "effective": null,
      "statedExpiry": null,
      "url": "https://www.gov.uk/guidance/construction-products-regulation-in-northern-ireland",
      "accessed": "2026-10-15",
      "establishes": "The equivalent rules for Northern Ireland, where products follow EU harmonised standards and carry CE or CE with UK(NI) marking; UKCA alone is not accepted.",
      "limits": null,
      "status": "current"
    },
    {
      "id": "src-gov-white-paper-2026",
      "issuer": "Ministry of Housing, Communities and Local Government",
      "title": "Construction Products Reform White Paper",
      "reference": "CP 1515",
      "type": "government_guidance",
      "group": "gb",
      "issued": "25 February 2026",
      "effective": null,
      "statedExpiry": null,
      "url": "https://assets.publishing.service.gov.uk/media/699c68cad2b9c6ec5b6fbbe8/Construction_Products_Reform_White_Paper.pdf",
      "accessed": "2026-10-15",
      "establishes": "The government's 2026 proposals for construction products, which describe UKCA and CE markings as a manufacturer's claim of conformity with declared performance, not a safety mark or an assurance of suitability for a particular use.",
      "limits": "Proposals; not law.",
      "status": "current"
    },
    {
      "id": "src-gov-ds-notice-0123-25",
      "issuer": "Ministry of Housing, Communities and Local Government",
      "title": "Notice of publication 0123/25: references to standards for construction products",
      "reference": "Notice 0123/25",
      "type": "government_guidance",
      "group": "gb",
      "issued": "26 September 2025",
      "effective": null,
      "statedExpiry": null,
      "url": "https://assets.publishing.service.gov.uk/media/68da4a7a8c1db6022d0c9e44/ds-0123-25-construction-products-notice.pdf",
      "accessed": "2026-10-15",
      "establishes": "The GB list of designated standards for construction products, which cites BS EN 15102:2007+A1:2011 for decorative wallcoverings.",
      "limits": null,
      "status": "current"
    },
    {
      "id": "src-cpr-art6-gb",
      "issuer": "legislation.gov.uk",
      "title": "Regulation (EU) No 305/2011 as it has effect in Great Britain, Article 6",
      "reference": "Article 6(3)(f)",
      "type": "legislation",
      "group": "gb",
      "issued": "9 March 2011 (revised GB text)",
      "effective": null,
      "statedExpiry": null,
      "url": "https://www.legislation.gov.uk/eur/2011/305/article/6",
      "accessed": "2026-10-15",
      "establishes": "What a declaration of performance must contain, including the letters NPD (no performance determined) where no performance is declared for a characteristic.",
      "limits": null,
      "status": "current"
    },
    {
      "id": "src-bsi-13501-1-landing",
      "issuer": "BSI",
      "title": "BS EN 13501-1 landing page (undated, all editions)",
      "reference": "UPI 000000000030059106",
      "type": "standard_catalogue",
      "group": "standards",
      "issued": "14 January 2019 (BSI page, for the 2018 edition)",
      "effective": null,
      "statedExpiry": null,
      "url": "https://landingpage.bsigroup.com/LandingPage/Undated?UPI=000000000030059106",
      "accessed": "2026-10-15",
      "establishes": "BSI catalogue record for BS EN 13501-1 and its editions: 2018 current; 2007+A1:2009 withdrawn in January 2019.",
      "limits": "A catalogue record confirms title, edition and status only; it does not reproduce the standard.",
      "status": "current"
    },
    {
      "id": "src-bsi-13501-1-kn",
      "issuer": "BSI",
      "title": "BS EN 13501-1:2018 BSI Knowledge record",
      "reference": "BS EN 13501-1:2018",
      "type": "standard_catalogue",
      "group": "standards",
      "issued": "31 January 2019 (BSI Knowledge)",
      "effective": null,
      "statedExpiry": null,
      "url": "https://knowledge.bsigroup.com/products/fire-classification-of-construction-products-and-building-elements-classification-using-data-from-reaction-to-fire-tests",
      "accessed": "2026-10-15",
      "establishes": "BSI Knowledge record for BS EN 13501-1:2018, current.",
      "limits": "A catalogue record confirms title, edition and status only; it does not reproduce the standard.",
      "status": "current"
    },
    {
      "id": "src-bsi-13823-kn",
      "issuer": "BSI",
      "title": "BS EN 13823:2020+A1:2022 BSI Knowledge record",
      "reference": "BS EN 13823:2020+A1:2022",
      "type": "standard_catalogue",
      "group": "standards",
      "issued": "31 January 2023 (BSI Knowledge)",
      "effective": null,
      "statedExpiry": null,
      "url": "https://knowledge.bsigroup.com/products/reaction-to-fire-tests-for-building-products-building-products-excluding-floorings-exposed-to-the-thermal-attack-by-a-single-burning-item-3",
      "accessed": "2026-10-15",
      "establishes": "BSI Knowledge record for BS EN 13823:2020+A1:2022, the single burning item test.",
      "limits": "A catalogue record confirms title, edition and status only; it does not reproduce the standard.",
      "status": "current"
    },
    {
      "id": "src-bsi-11925-2-kn",
      "issuer": "BSI",
      "title": "BS EN ISO 11925-2:2026 BSI Knowledge record",
      "reference": "BS EN ISO 11925-2:2026",
      "type": "standard_catalogue",
      "group": "standards",
      "issued": "31 January 2026 (BSI Knowledge)",
      "effective": null,
      "statedExpiry": null,
      "url": "https://knowledge.bsigroup.com/products/reaction-to-fire-tests-ignitability-of-products-subjected-to-direct-impingement-of-flame-single-flame-source-test-2",
      "accessed": "2026-10-15",
      "establishes": "BSI Knowledge record for BS EN ISO 11925-2:2026, the single-flame ignitability test.",
      "limits": "A catalogue record confirms title, edition and status only; it does not reproduce the standard.",
      "status": "current"
    },
    {
      "id": "src-bsi-1182-kn",
      "issuer": "BSI",
      "title": "BS EN ISO 1182:2020 BSI Knowledge record",
      "reference": "BS EN ISO 1182:2020",
      "type": "standard_catalogue",
      "group": "standards",
      "issued": "30 June 2020 (BSI Knowledge)",
      "effective": null,
      "statedExpiry": null,
      "url": "https://knowledge.bsigroup.com/products/reaction-to-fire-tests-for-products-non-combustibility-test",
      "accessed": "2026-10-15",
      "establishes": "BSI Knowledge record for BS EN ISO 1182:2020, the non-combustibility test.",
      "limits": "A catalogue record confirms title, edition and status only; it does not reproduce the standard.",
      "status": "current"
    },
    {
      "id": "src-bsi-1716-kn",
      "issuer": "BSI",
      "title": "BS EN ISO 1716:2018 BSI Knowledge record",
      "reference": "BS EN ISO 1716:2018",
      "type": "standard_catalogue",
      "group": "standards",
      "issued": "31 July 2018 (BSI Knowledge)",
      "effective": null,
      "statedExpiry": null,
      "url": "https://knowledge.bsigroup.com/products/reaction-to-fire-tests-for-products-determination-of-the-gross-heat-of-combustion-calorific-value-1",
      "accessed": "2026-10-15",
      "establishes": "BSI Knowledge record for BS EN ISO 1716:2018, the gross heat of combustion test.",
      "limits": "A catalogue record confirms title, edition and status only; it does not reproduce the standard.",
      "status": "current"
    },
    {
      "id": "src-bsi-15102-2019-kn",
      "issuer": "BSI",
      "title": "BS EN 15102:2019 Decorative wallcoverings. Roll form: BSI Knowledge record",
      "reference": "BS EN 15102:2019",
      "type": "standard_catalogue",
      "group": "standards",
      "issued": "30 June 2019 (BSI Knowledge)",
      "effective": null,
      "statedExpiry": null,
      "url": "https://knowledge.bsigroup.com/products/decorative-wallcoverings-roll-form",
      "accessed": "2026-10-15",
      "establishes": "BSI Knowledge record for BS EN 15102:2019, decorative wallcoverings in roll form, current at BSI.",
      "limits": "A catalogue record confirms title, edition and status only; it does not reproduce the standard.",
      "status": "current"
    },
    {
      "id": "src-bsi-15102-2007-kn",
      "issuer": "BSI",
      "title": "BS EN 15102:2007+A1:2011 Decorative wall coverings. Roll and panel form: BSI Knowledge record",
      "reference": "BS EN 15102:2007+A1:2011",
      "type": "standard_catalogue",
      "group": "standards",
      "issued": "30 November 2007 (BSI Knowledge)",
      "effective": null,
      "statedExpiry": null,
      "url": "https://knowledge.bsigroup.com/products/decorative-wall-coverings-roll-and-panel-form",
      "accessed": "2026-10-15",
      "establishes": "BSI Knowledge record for BS EN 15102:2007+A1:2011, roll and panel form, which BSI shows as withdrawn in June 2019.",
      "limits": "A catalogue record confirms title, edition and status only; it does not reproduce the standard.",
      "status": "current"
    },
    {
      "id": "src-bsi-13238-kn",
      "issuer": "BSI",
      "title": "BS EN 13238:2026 BSI Knowledge record",
      "reference": "BS EN 13238:2026",
      "type": "standard_catalogue",
      "group": "standards",
      "issued": "31 July 2026 (BSI Knowledge)",
      "effective": null,
      "statedExpiry": null,
      "url": "https://knowledge.bsigroup.com/products/reaction-to-fire-tests-for-building-products-conditioning-procedures-and-general-rules-for-selection-of-substrates-2",
      "accessed": "2026-10-15",
      "establishes": "BSI Knowledge record for BS EN 13238:2026, conditioning and the selection of substrates; the 2010 edition was withdrawn in August 2026.",
      "limits": "A catalogue record confirms title, edition and status only; it does not reproduce the standard.",
      "status": "current"
    },
    {
      "id": "src-bsi-15725-kn",
      "issuer": "BSI",
      "title": "BS EN 15725:2023 Extended application on the fire performance of construction products and building elements: Principle of EXAP standards and EXAP reports",
      "reference": "BS EN 15725:2023",
      "type": "standard_catalogue",
      "group": "standards",
      "issued": "31 March 2023",
      "effective": null,
      "statedExpiry": null,
      "url": "https://knowledge.bsigroup.com/products/extended-application-on-the-fire-performance-of-construction-products-and-building-elements-principle-of-exap-standards-and-exap-reports",
      "accessed": "2026-10-15",
      "establishes": "BSI Knowledge record for BS EN 15725:2023, extended application of fire performance.",
      "limits": "A catalogue record confirms title, edition and status only; it does not reproduce the standard.",
      "status": "current"
    },
    {
      "id": "src-bsi-13501-2-kn",
      "issuer": "BSI",
      "title": "BS EN 13501-2:2023 BSI Knowledge record",
      "reference": "BS EN 13501-2:2023",
      "type": "standard_catalogue",
      "group": "standards",
      "issued": "30 June 2023 (BSI Knowledge)",
      "effective": null,
      "statedExpiry": null,
      "url": "https://knowledge.bsigroup.com/products/fire-classification-of-construction-products-and-building-elements-classification-using-data-from-fire-resistance-and-or-smoke-control-tests-excluding-ventilation-services",
      "accessed": "2026-10-15",
      "establishes": "BSI Knowledge record for BS EN 13501-2:2023, fire resistance classification of building elements.",
      "limits": "A catalogue record confirms title, edition and status only; it does not reproduce the standard.",
      "status": "current"
    },
    {
      "id": "src-bsi-476-6-kn",
      "issuer": "BSI",
      "title": "BS 476-6:1989+A1:2009 Method of test for fire propagation for products",
      "reference": "BS 476-6:1989+A1:2009",
      "type": "standard_catalogue",
      "group": "standards",
      "issued": "31 March 1989",
      "effective": null,
      "statedExpiry": null,
      "url": "https://knowledge.bsigroup.com/products/fire-tests-on-building-materials-and-structures-method-of-test-for-fire-propagation-for-products",
      "accessed": "2026-10-15",
      "establishes": "BSI Knowledge record for BS 476-6:1989+A1:2009, fire propagation, withdrawn on 4 March 2025.",
      "limits": "A catalogue record confirms title, edition and status only; it does not reproduce the standard.",
      "status": "current"
    },
    {
      "id": "src-bsi-476-7-kn",
      "issuer": "BSI",
      "title": "BS 476-7:1997 Method of test to determine the classification of the surface spread of flame of products",
      "reference": "BS 476-7:1997",
      "type": "standard_catalogue",
      "group": "standards",
      "issued": "15 January 1997",
      "effective": null,
      "statedExpiry": null,
      "url": "https://knowledge.bsigroup.com/products/fire-tests-on-building-materials-and-structures-method-of-test-to-determine-the-classification-of-the-surface-spread-of-flame-of-products",
      "accessed": "2026-10-15",
      "establishes": "BSI Knowledge record for BS 476-7:1997, surface spread of flame, withdrawn on 4 March 2025.",
      "limits": "A catalogue record confirms title, edition and status only; it does not reproduce the standard.",
      "status": "current"
    },
    {
      "id": "src-bsi-476-article",
      "issuer": "BSI",
      "title": "The changing status of the BS 476 standard series: A summary (BSI Knowledge article)",
      "reference": "BSI Knowledge article, 19 Feb 2025",
      "type": "webpage",
      "group": "standards",
      "issued": "19 February 2025",
      "effective": null,
      "statedExpiry": null,
      "url": "https://knowledge.bsigroup.com/articles/the-changing-status-of-the-bs-476-standard-series-a-summary",
      "accessed": "2026-10-15",
      "establishes": "BSI's own summary of the changing status of the BS 476 series and its removal from England's guidance.",
      "limits": "A BSI explanatory article; it reports status changes and is not the standard.",
      "status": "current"
    },
    {
      "id": "src-reg-2016-364-legis",
      "issuer": "European Commission (text on legislation.gov.uk)",
      "title": "Commission Delegated Regulation (EU) 2016/364 on the classification of the reaction to fire performance of construction products",
      "reference": "Annex, Table 1",
      "type": "eu_legislation",
      "group": "eu",
      "issued": "Adopted 1 July 2015; published 15 March 2016",
      "effective": null,
      "statedExpiry": null,
      "url": "https://www.legislation.gov.uk/eur/2016/364/contents",
      "accessed": "2026-10-15",
      "establishes": "The legal definitions of the reaction-to-fire classes A1 to F and the smoke (s1 to s3) and droplet (d0 to d2) subclasses, with the test criteria for each.",
      "limits": null,
      "status": "current"
    },
    {
      "id": "src-dec-2010-82",
      "issuer": "European Commission (text on legislation.gov.uk)",
      "title": "Commission Decision 2010/82/EU establishing the classes of reaction-to-fire performance for decorative wallcoverings without further testing",
      "reference": "Decision 2010/82/EU",
      "type": "eu_legislation",
      "group": "eu",
      "issued": "9 February 2010",
      "effective": null,
      "statedExpiry": null,
      "url": "https://www.legislation.gov.uk/eudn/2010/82/contents",
      "accessed": "2026-10-15",
      "establishes": "The list of decorative wallcoverings that may be classed D-s3,d2 without further testing, within stated limits of mass, thickness, substrate and adhesive.",
      "limits": null,
      "status": "current"
    },
    {
      "id": "src-ec-cpr-summary-2026",
      "issuer": "European Commission",
      "title": "Summary list of harmonised standards under Regulation (EU) No 305/2011",
      "reference": "Commission summary list, 9.2.2026",
      "type": "government_guidance",
      "group": "eu",
      "issued": "9 February 2026 (generated)",
      "effective": null,
      "statedExpiry": null,
      "url": "https://single-market-economy.ec.europa.eu/document/download/b7ff8581-3a87-4d72-98d6-41301f56d888_en?filename=305_2011_CPR_Summary%20list%20of%20harmonised%20standards_Generated%20on%209.2.2026.pdf",
      "accessed": "2026-10-15",
      "establishes": "The European Commission's summary list of harmonised standards, which cites EN 15102:2007+A1:2011 for decorative wallcoverings.",
      "limits": null,
      "status": "current"
    },
    {
      "id": "src-astm-e84",
      "issuer": "ASTM International",
      "title": "ASTM E84-26a: Standard Test Method for Surface Burning Characteristics of Building Materials",
      "reference": "ASTM E84-26a",
      "type": "standard_catalogue",
      "group": "international",
      "issued": "15 April 2026 (store page last updated)",
      "effective": null,
      "statedExpiry": null,
      "url": "https://store.astm.org/e0084-26a.html",
      "accessed": "2026-10-15",
      "establishes": "ASTM's catalogue record for E84, the US tunnel test that reports flame spread and smoke developed indices.",
      "limits": "A catalogue record only. A US test, not a European class.",
      "status": "current"
    },
    {
      "id": "src-imo-msc307",
      "issuer": "International Maritime Organization",
      "title": "Resolution MSC.307(88): International Code for Application of Fire Test Procedures, 2010 (FTP Code)",
      "reference": "Part 5",
      "type": "international_code",
      "group": "international",
      "issued": "3 December 2010",
      "effective": null,
      "statedExpiry": null,
      "url": "https://wwwcdn.imo.org/localresources/en/KnowledgeCentre/IndexofIMOResolutions/MSCResolutions/MSC.307(88).pdf",
      "accessed": "2026-10-15",
      "establishes": "The IMO's 2010 Fire Test Procedures Code, whose Part 5 is a marine surface-flammability test with its own criteria.",
      "limits": "Marine approval system; not a building classification.",
      "status": "current"
    },
    {
      "id": "src-bsi-5852-kn",
      "issuer": "BSI",
      "title": "BS 5852:2006 Methods of test for assessment of the ignitability of upholstered seating by smouldering and flaming ignition sources",
      "reference": "BS 5852:2006",
      "type": "standard_catalogue",
      "group": "international",
      "issued": "31 March 2006",
      "effective": null,
      "statedExpiry": null,
      "url": "https://knowledge.bsigroup.com/products/methods-of-test-for-assessment-of-the-ignitability-of-upholstered-seating-by-smouldering-and-flaming-ignition-sources",
      "accessed": "2026-10-15",
      "establishes": "BSI catalogue record for BS 5852:2006, ignitability of upholstered seating: not a wallcovering test.",
      "limits": null,
      "status": "current"
    },
    {
      "id": "src-bsi-5867-2-kn",
      "issuer": "BSI",
      "title": "BS 5867-2:2008 Fabrics for curtains, drapes and window blinds. Flammability requirements. Specification",
      "reference": "BS 5867-2:2008",
      "type": "standard_catalogue",
      "group": "international",
      "issued": "30 May 2008",
      "effective": null,
      "statedExpiry": null,
      "url": "https://knowledge.bsigroup.com/products/fabrics-for-curtains-drapes-and-window-blinds-flammability-requirements-specification",
      "accessed": "2026-10-15",
      "establishes": "BSI catalogue record for BS 5867-2:2008, flammability of curtain fabrics: not a wallcovering test.",
      "limits": null,
      "status": "current"
    },
    {
      "id": "src-bsi-13773-kn",
      "issuer": "BSI",
      "title": "BS EN 13773:2003 Textiles and textile products. Burning behaviour. Curtains and drapes. Classification scheme",
      "reference": "BS EN 13773:2003",
      "type": "standard_catalogue",
      "group": "international",
      "issued": "19 February 2003",
      "effective": null,
      "statedExpiry": null,
      "url": "https://knowledge.bsigroup.com/products/textiles-and-textile-products-burning-behaviour-curtains-and-drapes-classification-scheme",
      "accessed": "2026-10-15",
      "establishes": "BSI catalogue record for BS EN 13773:2003, classification of curtains and drapes: not a wallcovering test.",
      "limits": null,
      "status": "current"
    },
    {
      "id": "src-muraspec-dop-0493-cpr0003-2025",
      "issuer": "Muraspec",
      "title": "Declaration of performance CPR0003, version 4",
      "reference": null,
      "type": "declaration_of_performance",
      "group": "manufacturer",
      "issued": "4 July 2025 (signed)",
      "effective": null,
      "statedExpiry": null,
      "url": "https://www.muraspec.com/wp-content/uploads/2025/07/DOP-0493-CPR0003.pdf",
      "accessed": "2026-10-15",
      "establishes": "Muraspec's 2025 declaration of performance covering several fabric-backed and paper-backed vinyl types, each declared B-s2,d0 on fibre-cement board with Murabond Heavy adhesive.",
      "limits": null,
      "status": "current"
    },
    {
      "id": "src-muraspec-dop-cpr0004-2024-bttg",
      "issuer": "Muraspec",
      "title": "Declaration of performance CPR0004, version 1",
      "reference": null,
      "type": "declaration_of_performance",
      "group": "manufacturer",
      "issued": "4 September 2024 (signed)",
      "effective": null,
      "statedExpiry": null,
      "url": "https://www.muraspec.com/wp-content/uploads/2024/09/DOP-CPR0004-Muraspec-Version-BTTG-FBV-Woven-Scrim-360-gsm-s1.pdf",
      "accessed": "2026-10-15",
      "establishes": "Muraspec's declaration for woven Type I fabric-backed vinyl at 360 gsm, declared B-s1,d0 on fibre-cement board with Murabond Heavy adhesive.",
      "limits": null,
      "status": "current"
    },
    {
      "id": "src-muraspec-dop-cpr0003-2024-bttg",
      "issuer": "Muraspec",
      "title": "Declaration of performance CPR0003, version 1 (digital print bases)",
      "reference": null,
      "type": "declaration_of_performance",
      "group": "manufacturer",
      "issued": "4 September 2024 (signed)",
      "effective": null,
      "statedExpiry": null,
      "url": "https://www.muraspec.com/wp-content/uploads/2024/09/DOP-CPR0003-Muraspec-Version-BTTG-FBV-NW-Digi-Print-300-350-gsm-s2.pdf",
      "accessed": "2026-10-15",
      "establishes": "Muraspec's 2024 declaration for two digitally printed fabric-backed vinyl bases, declared B-s2,d0 on fibre-cement board with Murabond Heavy adhesive.",
      "limits": null,
      "status": "current"
    },
    {
      "id": "src-muraspec-dop-cpr0005-2024-bttg",
      "issuer": "Muraspec",
      "title": "Declaration of performance CPR0005, version 1",
      "reference": null,
      "type": "declaration_of_performance",
      "group": "manufacturer",
      "issued": "4 September 2024 (signed)",
      "effective": null,
      "statedExpiry": null,
      "url": "https://www.muraspec.com/wp-content/uploads/2024/09/DOP-CPR0005-Muraspec-Version-BTTG-Non-Woven-Non-PVC-RS.pdf",
      "accessed": "2026-10-15",
      "establishes": "Muraspec's declaration for rotary-screen printed non-woven, non-PVC wallcovering at 200 gsm, declared B-s1,d0 on fibre-cement board with Murabond Heavy adhesive.",
      "limits": null,
      "status": "current"
    },
    {
      "id": "src-muraspec-hanging-leaflet-2026-05",
      "issuer": "Muraspec",
      "title": "Hanging information leaflet (UK)",
      "reference": null,
      "type": "technical_sheet",
      "group": "manufacturer",
      "issued": "May 2026",
      "effective": null,
      "statedExpiry": null,
      "url": "https://www.muraspec.com/wp-content/uploads/2026/05/Muraspec-UK-Hanging-Instructions-May-26.pdf",
      "accessed": "2026-10-15",
      "establishes": "Muraspec's hanging instructions, including adhesive choice by wall type and the instruction not to hang over expanded polystyrene veneer.",
      "limits": null,
      "status": "current"
    },
    {
      "id": "src-muraspec-web-product-bm-61527103",
      "issuer": "Muraspec",
      "title": "Product page: Buflon Mousse Anafi (BM-61527103)",
      "reference": null,
      "type": "webpage",
      "group": "manufacturer",
      "issued": null,
      "effective": null,
      "statedExpiry": null,
      "url": "https://www.muraspec.com/product/bm-61527103/",
      "accessed": "2026-10-15",
      "establishes": "A Muraspec product page that states Euroclass C S3 D0 for an acoustic foam vinyl.",
      "limits": null,
      "status": "current"
    },
    {
      "id": "src-muraspec-web-product-13602",
      "issuer": "Muraspec",
      "title": "Product page 13602 (Frequency)",
      "reference": null,
      "type": "webpage",
      "group": "manufacturer",
      "issued": null,
      "effective": null,
      "statedExpiry": null,
      "url": "https://www.muraspec.com/product/13602/",
      "accessed": "2026-10-15",
      "establishes": "Muraspec's product page for Frequency 13602, which gives 'Certificate of Performance: CPR0004' and 'Weight: 460gsm'.",
      "limits": "A web page; it gives no class or build-up of its own.",
      "status": "current"
    },
    {
      "id": "src-tektura-geometrics-techsheet",
      "issuer": "Tektura",
      "title": "Technical specification: Geometrics",
      "reference": null,
      "type": "technical_sheet",
      "group": "manufacturer",
      "issued": null,
      "effective": null,
      "statedExpiry": null,
      "url": "https://tekturawebsite.s3.eu-west-2.amazonaws.com/uploads/design/46/geometrics-tech-data-24.pdf",
      "accessed": "2026-10-15",
      "establishes": "Tektura's combined technical sheet for Geometrics digital prints, window graphics and acoustic panels; its wallcovering fire line reads Euro classification B when adhered to a suitable substrate.",
      "limits": "No date printed; the file name refers to 2024.",
      "status": "current"
    },
    {
      "id": "src-tektura-dimity-weave-techsheet",
      "issuer": "Tektura",
      "title": "Technical specification: Dimity Weave",
      "reference": null,
      "type": "technical_sheet",
      "group": "manufacturer",
      "issued": null,
      "effective": null,
      "statedExpiry": null,
      "url": "https://tekturawebsite.s3.eu-west-2.amazonaws.com/uploads/design/303/dimity-weave-technical-data.pdf",
      "accessed": "2026-10-15",
      "establishes": "Tektura's technical sheet for Dimity Weave, printing B s1 d0.",
      "limits": null,
      "status": "current"
    },
    {
      "id": "src-tektura-web-dimity-weave",
      "issuer": "Tektura",
      "title": "Dimity Weave product page",
      "reference": null,
      "type": "webpage",
      "group": "manufacturer",
      "issued": null,
      "effective": null,
      "statedExpiry": null,
      "url": "https://www.tektura.com/product/dimity-weave",
      "accessed": "2026-10-15",
      "establishes": "Tektura's Dimity Weave product page, which tags the fire rating 'Euroclass B' and 'Marine (please enquire)'.",
      "limits": "Gives no subclasses, report, substrate or adhesive.",
      "status": "current"
    },
    {
      "id": "src-tektura-rivulet-techsheet",
      "issuer": "Tektura",
      "title": "Technical specification: Rivulet",
      "reference": null,
      "type": "technical_sheet",
      "group": "manufacturer",
      "issued": null,
      "effective": null,
      "statedExpiry": null,
      "url": "https://tekturawebsite.s3.eu-west-2.amazonaws.com/uploads/design/366/rivulet-technical-data.pdf",
      "accessed": "2026-10-15",
      "establishes": "Tektura's technical sheet for Rivulet, printing B s2 d0.",
      "limits": null,
      "status": "current"
    },
    {
      "id": "src-tektura-web-rivulet",
      "issuer": "Tektura",
      "title": "Rivulet product page",
      "reference": null,
      "type": "webpage",
      "group": "manufacturer",
      "issued": null,
      "effective": null,
      "statedExpiry": null,
      "url": "https://www.tektura.com/product/rivulet",
      "accessed": "2026-10-15",
      "establishes": "Tektura's Rivulet product page, which tags the fire rating 'Euroclass B' and 'Marine (please enquire)'.",
      "limits": "Gives no subclasses, report, substrate or adhesive.",
      "status": "current"
    },
    {
      "id": "src-tektura-shimmy-techsheet",
      "issuer": "Tektura",
      "title": "Technical specification: Shimmy",
      "reference": null,
      "type": "technical_sheet",
      "group": "manufacturer",
      "issued": null,
      "effective": null,
      "statedExpiry": null,
      "url": "https://tekturawebsite.s3.eu-west-2.amazonaws.com/uploads/attachments/2025-08-14/Shimmy%20Technical%20Data%20%20.pdf",
      "accessed": "2026-10-15",
      "establishes": "Tektura's technical sheet for Shimmy, printing C-s1-d0.",
      "limits": "No date printed; upload path dated 2025-08-14.",
      "status": "current"
    },
    {
      "id": "src-tektura-temple-techsheet",
      "issuer": "Tektura",
      "title": "Technical specification: Temple",
      "reference": null,
      "type": "technical_sheet",
      "group": "manufacturer",
      "issued": null,
      "effective": null,
      "statedExpiry": null,
      "url": "https://tekturawebsite.s3.eu-west-2.amazonaws.com/uploads/attachments/2026-08-25/Temple%20Technical%20Data.pdf",
      "accessed": "2026-10-15",
      "establishes": "Tektura's technical sheet for Temple, printing Euroclass B.",
      "limits": "No date printed; upload path dated 2026-08-25.",
      "status": "current"
    },
    {
      "id": "src-tektura-web-temple",
      "issuer": "Tektura",
      "title": "Product page: Temple",
      "reference": null,
      "type": "webpage",
      "group": "manufacturer",
      "issued": null,
      "effective": null,
      "statedExpiry": null,
      "url": "https://www.tektura.com/product/temple",
      "accessed": "2026-10-15",
      "establishes": "Tektura's Temple product page, which tags the product Euroclass C.",
      "limits": null,
      "status": "current"
    },
    {
      "id": "src-tektura-tiburon-shagreen-techsheet",
      "issuer": "Tektura",
      "title": "Technical specification: Tiburon Shagreen",
      "reference": null,
      "type": "technical_sheet",
      "group": "manufacturer",
      "issued": null,
      "effective": null,
      "statedExpiry": null,
      "url": "https://tekturawebsite.s3.eu-west-2.amazonaws.com/uploads/attachments/2026-08-20/Tiburon%20Shagreen%20technical%20data.pdf",
      "accessed": "2026-10-15",
      "establishes": "Tektura's technical sheet for Tiburon Shagreen, printing Euroclass B and BS 476 Class 0 and 1 when adhered to a suitable substrate.",
      "limits": "No date printed; upload path dated 2026-08-20.",
      "status": "current"
    },
    {
      "id": "src-vescom-f1546-efectis-350",
      "issuer": "Efectis Nederland",
      "title": "Classification of reaction to fire performance: vinyl wallcovering 350 g/m²",
      "reference": null,
      "type": "classification_report",
      "group": "manufacturer",
      "issued": "August 2023",
      "effective": null,
      "statedExpiry": null,
      "url": "https://documents.vescom-cdn.com/f1546/Colour%20Choice%2Bprint%201036%20-%20EN%2013501%2C%20B%20s1%20d0.pdf",
      "accessed": "2026-10-15",
      "establishes": "Classification report on a plain white 350 g/m² Vescom vinyl: B-s1,d0 on 12 mm calcium silicate board with Vescom 3000.",
      "limits": null,
      "status": "current"
    },
    {
      "id": "src-vescom-f16185-dop-01006",
      "issuer": "Vescom",
      "title": "Declaration of performance DOP-CPR-01006",
      "reference": null,
      "type": "declaration_of_performance",
      "group": "manufacturer",
      "issued": "25 August 2023",
      "effective": null,
      "statedExpiry": null,
      "url": "https://documents.vescom-cdn.com/f16185/DoP-CPR-01006%20-%20350%20grs%20vinyl.pdf",
      "accessed": "2026-10-15",
      "establishes": "Vescom's declaration of performance for 350 g/m² cotton-backed vinyl.",
      "limits": null,
      "status": "current"
    },
    {
      "id": "src-vescom-f16184-dop-01001",
      "issuer": "Vescom",
      "title": "Declaration of performance DOP-CPR-01001",
      "reference": null,
      "type": "declaration_of_performance",
      "group": "manufacturer",
      "issued": "27 August 2024",
      "effective": null,
      "statedExpiry": null,
      "url": "https://documents.vescom-cdn.com/f16184/DoP-CPR-01001%20-%20360-850%20grs%20vinyl.pdf",
      "accessed": "2026-10-15",
      "establishes": "Vescom's family declaration for cotton-backed FR vinyl of 360 to 850 g/m², declared B-s2,d0.",
      "limits": null,
      "status": "current"
    },
    {
      "id": "src-vescom-f103-ce-vinyl",
      "issuer": "Centexbel",
      "title": "Certificate of constancy of performance 0493-CPR-W014, with annex",
      "reference": null,
      "type": "certificate",
      "group": "manufacturer",
      "issued": "5 March 2021",
      "effective": null,
      "statedExpiry": "2023-07-31",
      "url": "https://documents.vescom-cdn.com/f103/CE%20-%20Vescom%20-%20vinyl%20wallcovering.pdf",
      "accessed": "2026-10-15",
      "establishes": "The 2021 certificate of constancy of performance behind Vescom's vinyl family declaration, with its field of application (excluding plasterboard) and a printed validity date.",
      "limits": null,
      "status": "current"
    },
    {
      "id": "src-vescom-specsheet-ccp-gb",
      "issuer": "Vescom",
      "title": "Specsheet: Colour Choice+Protect",
      "reference": null,
      "type": "technical_sheet",
      "group": "manufacturer",
      "issued": null,
      "effective": null,
      "statedExpiry": null,
      "url": "https://api-services.vescom.com/product/specsheet/colour-choiceprotect/en-GB",
      "accessed": "2026-10-15",
      "establishes": "Vescom's specsheet for Colour Choice+Protect, printing B s2 d0 with no test details.",
      "limits": null,
      "status": "current"
    },
    {
      "id": "src-vescom-page-colour-choice-protect",
      "issuer": "Vescom",
      "title": "Product page: Colour Choice+Protect",
      "reference": null,
      "type": "webpage",
      "group": "manufacturer",
      "issued": null,
      "effective": null,
      "statedExpiry": null,
      "url": "https://vescom.com/en/products/colour-choiceprotect",
      "accessed": "2026-10-15",
      "establishes": "Vescom's Colour Choice+Protect product page and its linked documents.",
      "limits": null,
      "status": "current"
    },
    {
      "id": "src-vescom-f18987-ccprotect-crepim",
      "issuer": "CREPIM",
      "title": "Classification report DO-18-0159\\A-R1 (Vescom Rainy)",
      "reference": null,
      "type": "classification_report",
      "group": "manufacturer",
      "issued": "21 August 2018",
      "effective": null,
      "statedExpiry": "2023-08-21",
      "url": "https://documents.vescom-cdn.com/f18987/Colour%20Choice%2Bprotect%201126PRO%20-%20EN%2013501%2C%20B%20s2%20d0.pdf",
      "accessed": "2026-10-15",
      "establishes": "The classification report linked from the Colour Choice+Protect page; it describes a Vescom vinyl called Rainy, without a Protect layer, as B-s2,d0, and is printed as valid for five years from 21 August 2018.",
      "limits": null,
      "status": "current"
    },
    {
      "id": "src-vescom-f2512-dop-01002",
      "issuer": "Vescom",
      "title": "Declaration of performance DOP-CPR-01002 (vinyl wallcovering with Vescom Protect, 370–480 g/m²)",
      "reference": "DOP-CPR-01002",
      "type": "declaration_of_performance",
      "group": "manufacturer",
      "issued": "7 July 2017",
      "effective": null,
      "statedExpiry": null,
      "url": "https://documents.vescom-cdn.com/f2512/DoP-CPR-01002%20-%20370-480%20grs%20vinyl%2Bprotect.pdf",
      "accessed": "2026-10-15",
      "establishes": "Vescom's Protect family declaration: cotton-backed vinyl with Vescom Protect, FR treated, 370–480 g/m², System 1, B-s2,d0, citing Centexbel certificate 0493-CPR-W015.",
      "limits": "A family declaration over a mass range; it names no substrate or adhesive.",
      "status": "current"
    },
    {
      "id": "src-vescom-f278-ce-vinyl-protect",
      "issuer": "Centexbel",
      "title": "Certificate of constancy of performance 0493-CPR-W015 (Vescom vinyl wallcovering with Vescom Protect)",
      "reference": "0493-CPR-W015",
      "type": "certificate",
      "group": "manufacturer",
      "issued": "29 July 2021 (first issued 7 July 2017)",
      "effective": null,
      "statedExpiry": "2023-07-31",
      "url": "https://documents.vescom-cdn.com/f278/CE%20-%20Vescom%20-%20vinyl%20wallcovering%2Bprotect.pdf",
      "accessed": "2026-10-15",
      "establishes": "Certificate W015: vinyl 310 g/m², cotton 40 g/m² and Protect laminate 20 g/m² (370 g/m² in all), B-s2,d0 on calcium silicate with Vescom 2000 and vertical joints. Its annex cites MPA Dresden classification 20180730/01 of Pleso + Protect, limited to the tested 356 g/m² and 0.31 mm and excluding gypsum boards.",
      "limits": "States it is valid 'latest on July 31st 2023'. No Protect test at about 460 g/m² is included.",
      "status": "current"
    },
    {
      "id": "src-vescom-f16802-efectis-porak",
      "issuer": "Efectis Nederland",
      "title": "Classification of reaction to fire performance: Porak+print",
      "reference": null,
      "type": "classification_report",
      "group": "manufacturer",
      "issued": "January 2025",
      "effective": null,
      "statedExpiry": null,
      "url": "https://documents.vescom-cdn.com/f16802/Porak%2Bprint%201041%20-%20EN%2013501%2C%20B%20s2%20d0.pdf",
      "accessed": "2026-10-15",
      "establishes": "Classification report on Porak+print: B-s2,d0 on an A1/A2 board with Vescom 2500.",
      "limits": null,
      "status": "current"
    },
    {
      "id": "src-vescom-f18446-tapetex-69-2341",
      "issuer": "Warringtonfire (Ghent)",
      "title": "Reaction to fire classification report 22965F: woven textile quality 69-2341",
      "reference": null,
      "type": "classification_report",
      "group": "manufacturer",
      "issued": "October 2023",
      "effective": null,
      "statedExpiry": null,
      "url": "https://documents.vescom-cdn.com/f18446/Textile%20wallcovering%20-%20EN%2013501%20-%2069-2341.pdf",
      "accessed": "2026-10-15",
      "establishes": "Classification report on a woven textile quality (69-2341) on paper backing: B-s1,d0, excluding paper-faced plasterboard.",
      "limits": null,
      "status": "current"
    },
    {
      "id": "src-vescom-f2534-dop-13008",
      "issuer": "Vescom",
      "title": "Declaration of performance DOP-CPR-13008",
      "reference": null,
      "type": "declaration_of_performance",
      "group": "manufacturer",
      "issued": "1 January 2023",
      "effective": null,
      "statedExpiry": null,
      "url": "https://documents.vescom-cdn.com/f2534/DoP-CPR-13008%20-%20nonwoven%20onelayer%2C%20digitally%20printed.pdf",
      "accessed": "2026-10-15",
      "establishes": "Vescom's declaration for digitally printed one-layer non-woven, declared B-s1,d0.",
      "limits": null,
      "status": "current"
    },
    {
      "id": "src-arte-dop-moire-sauvage-uk",
      "issuer": "Arte NV",
      "title": "Declaration of performance DoP-CPR-24-3959 (UK): Moire Sauvage",
      "reference": null,
      "type": "declaration_of_performance",
      "group": "manufacturer",
      "issued": "21 June 2024",
      "effective": null,
      "statedExpiry": null,
      "url": "https://edge.arte-international.com/media/9a922cd2-cc66-42c0-86c4-10fc4df8de0f/DOP_Moire-Sauvage_UK.pdf",
      "accessed": "2026-10-15",
      "establishes": "Arte's UK declaration of performance for Moire Sauvage (14 references), declared B-s2,d0.",
      "limits": null,
      "status": "current"
    },
    {
      "id": "src-centexbel-cocp-0493-cpr-w038",
      "issuer": "Centexbel",
      "title": "Certificate of constancy of performance 0493-CPR-W038",
      "reference": null,
      "type": "certificate",
      "group": "manufacturer",
      "issued": "First issued 27 July 2023; current version signed 28 July 2026",
      "effective": null,
      "statedExpiry": "2029-07-28",
      "url": "https://edge.arte-international.com/media/654cb149-6fef-453a-8c70-c7cbd70d2ec3/7A.-Contract-vinyl-20oz.pdf",
      "accessed": "2026-10-15",
      "establishes": "The certificate behind Arte's contract vinyl family, giving B-s2,d0 glued on fibre-cement with vertical joints for FR vinyls of 451 to 790 g/m², and a printed validity date.",
      "limits": null,
      "status": "current"
    },
    {
      "id": "src-arte-spec-47253a",
      "issuer": "Arte NV",
      "title": "Specification sheet 47253A (Moire Sauvage)",
      "reference": null,
      "type": "technical_sheet",
      "group": "manufacturer",
      "issued": null,
      "effective": null,
      "statedExpiry": null,
      "url": "https://pdf.arte-international.com/en/specification-sheets/47253A",
      "accessed": "2026-10-15",
      "establishes": "Arte's specification sheet for Moire Sauvage 47253A, printing \"Fire rating EU B-s2, d0\" with no test substrate, test adhesive or report reference.",
      "limits": null,
      "status": "current"
    },
    {
      "id": "src-arte-spec-31000",
      "issuer": "Arte NV",
      "title": "Specification sheet 31000 (Le Corbusier Dots)",
      "reference": null,
      "type": "technical_sheet",
      "group": "manufacturer",
      "issued": null,
      "effective": null,
      "statedExpiry": null,
      "url": "https://pdf.arte-international.com/en/specification-sheets/31000",
      "accessed": "2026-10-15",
      "establishes": "Arte's specification sheet for Le Corbusier Dots 31000: wallpaper on non-woven backing, hung with Arte Clearpro or a good quality dispersion adhesive.",
      "limits": "Installation guidance; it gives no test substrate, test adhesive or report reference.",
      "status": "current"
    },
    {
      "id": "src-arte-dop-le-corbusier-dots-uk",
      "issuer": "Arte NV",
      "title": "Declaration of performance DoP-CPR-15-3350 (UK): Le Corbusier Dots",
      "reference": null,
      "type": "declaration_of_performance",
      "group": "manufacturer",
      "issued": "11 April 2022",
      "effective": null,
      "statedExpiry": null,
      "url": "https://edge.arte-international.com/media/72bc5cd0-e2fc-4c29-95ca-b1385c9e7cf4/DOP_Le-Corbusier-Dots_UK.pdf",
      "accessed": "2026-10-15",
      "establishes": "Arte's UK declaration for Le Corbusier Dots (references 31000 to 31039), declared B-s1,d0.",
      "limits": null,
      "status": "current"
    },
    {
      "id": "src-centexbel-report-19-721",
      "issuer": "Centexbel",
      "title": "Certification report 19/721: type 01 non-woven wallcovering",
      "reference": null,
      "type": "classification_report",
      "group": "manufacturer",
      "issued": "18 September 2026",
      "effective": null,
      "statedExpiry": "2027-07-28",
      "url": "https://edge.arte-international.com/media/a35e5b4c-c34b-41a2-bfc7-3ebb4c480961/1.-Wallcovering-non-woven,-waterbased-ink,-decorative-elements.pdf",
      "accessed": "2026-10-15",
      "establishes": "Centexbel's group report for type 01 non-woven wallcoverings: B-s1,d0 with starch glue on substrates of at least 1,350 kg/m³; printed validity date.",
      "limits": null,
      "status": "current"
    },
    {
      "id": "src-arte-dop-indienne-uk",
      "issuer": "Arte NV",
      "title": "Declaration of performance DoP-CPR-100001000026-00020 (UK): Indienne",
      "reference": null,
      "type": "declaration_of_performance",
      "group": "manufacturer",
      "issued": "2 April 2026",
      "effective": null,
      "statedExpiry": null,
      "url": "https://edge.arte-international.com/media/ad97b62f-99ec-421b-b964-449d40485fed/DOP-Indienne---UKxlsx.pdf",
      "accessed": "2026-10-15",
      "establishes": "Arte's UK declaration for six Indienne designs, declared B-s2,d0.",
      "limits": null,
      "status": "current"
    },
    {
      "id": "src-centexbel-report-19-720",
      "issuer": "Centexbel",
      "title": "Certification report 19/720: type 03 vinyl wallcovering",
      "reference": null,
      "type": "classification_report",
      "group": "manufacturer",
      "issued": "18 September 2026",
      "effective": null,
      "statedExpiry": "2030-01-12",
      "url": "https://edge.arte-international.com/media/bebd4e6b-2d4c-4865-8fdd-73c1e7497fca/3.-Vinyl-wallcovering-with-water-based-ink.pdf",
      "accessed": "2026-10-15",
      "establishes": "Centexbel's group report for type 03 vinyl wallcoverings: B-s2,d0 with starch glue on dense substrates; printed validity date.",
      "limits": null,
      "status": "current"
    },
    {
      "id": "src-arte-dop-les-tapisseries-06d-uk",
      "issuer": "Arte NV",
      "title": "Declaration of performance DoP-CPR-100003000026-00040/2 (UK): Les Tapisseries 06D",
      "reference": null,
      "type": "declaration_of_performance",
      "group": "manufacturer",
      "issued": "2 April 2026",
      "effective": null,
      "statedExpiry": null,
      "url": "https://edge.arte-international.com/media/c32e1774-67fd-4a3c-bfe3-3260b366cf0b/DOP-Les-Tapisseries-06D---UKxlsx.pdf",
      "accessed": "2026-10-15",
      "establishes": "Arte's UK declaration for Brocade and Ramage, declared C-s1,d0.",
      "limits": null,
      "status": "current"
    },
    {
      "id": "src-centexbel-report-20-1150",
      "issuer": "Centexbel",
      "title": "Certification report 20/1150: type 06D textile wallcovering",
      "reference": null,
      "type": "classification_report",
      "group": "manufacturer",
      "issued": "4 August 2026",
      "effective": null,
      "statedExpiry": "2029-12-22",
      "url": "https://edge.arte-international.com/media/cad0a19c-e130-45dc-aafa-d809935f54b4/6D.-Wallcovering-with-textile.pdf",
      "accessed": "2026-10-15",
      "establishes": "Centexbel's group report for type 06D textile wallcoverings: C-s1,d0 with starch glue on dense substrates; printed validity date.",
      "limits": null,
      "status": "current"
    },
    {
      "id": "src-centexbel-report-18-667",
      "issuer": "Centexbel",
      "title": "Certification report 18/667: type 06C textile wallcovering",
      "reference": null,
      "type": "classification_report",
      "group": "manufacturer",
      "issued": "17 June 2026",
      "effective": null,
      "statedExpiry": "2029-11-19",
      "url": "https://edge.arte-international.com/media/6aff0210-4ea7-4ffc-aa9c-705a9b12b072/6C.-Wallcovering-with-textile.pdf",
      "accessed": "2026-10-15",
      "establishes": "Centexbel's group report for type 06C textile wallcoverings: D-s1,d0 with starch glue on dense substrates; printed validity date.",
      "limits": null,
      "status": "current"
    },
    {
      "id": "src-arte-dop-les-tapisseries-06c-uk",
      "issuer": "Arte NV",
      "title": "Declaration of performance DoP-CPR-100003000026-00040/5 (UK): Les Tapisseries 06C",
      "reference": null,
      "type": "declaration_of_performance",
      "group": "manufacturer",
      "issued": "2 April 2026",
      "effective": null,
      "statedExpiry": null,
      "url": "https://edge.arte-international.com/media/7fa67911-3d50-4e1d-bfa7-5ffbf2e94ad9/DOP-Les-Tapisseries-06C---UKxlsx.pdf",
      "accessed": "2026-10-15",
      "establishes": "Arte's UK declaration for Collines, which declares C-s1,d0 while citing report 18/667.",
      "limits": null,
      "status": "current"
    },
    {
      "id": "src-newmor-cnbop-082-bw-22",
      "issuer": "CNBOP-PIB",
      "title": "Classification report 082/BW/22: Premier Nonwoven 460 g/m²",
      "reference": null,
      "type": "classification_report",
      "group": "manufacturer",
      "issued": "20 September 2022",
      "effective": null,
      "statedExpiry": null,
      "url": "https://newmor.com/wp-content/uploads/2025/03/460gsm-nonwoven-CNBOP.pdf",
      "accessed": "2026-10-15",
      "establishes": "Classification report on Premier 460 g/m² non-woven vinyl: B-s1,d0 on fibre-cement board, excluding paper plasterboard.",
      "limits": null,
      "status": "current"
    },
    {
      "id": "src-newmor-bttg-27-06068b",
      "issuer": "BTTG",
      "title": "Test report 27/06068B/01/23: Premier 400 g/m² non-woven",
      "reference": null,
      "type": "test_report",
      "group": "manufacturer",
      "issued": "14 February 2023",
      "effective": null,
      "statedExpiry": null,
      "url": "https://newmor.com/wp-content/uploads/2024/02/400gsm-Nonwoven-backed.pdf",
      "accessed": "2026-10-15",
      "establishes": "Test report on a Premier 400 g/m² non-woven vinyl sample, giving B-s2,d0 as definite and s1 only as probable.",
      "limits": null,
      "status": "current"
    },
    {
      "id": "src-newmor-exova-314369",
      "issuer": "Exova Warringtonfire",
      "title": "Classification report 314369: Project paper-backed wallcovering",
      "reference": null,
      "type": "classification_report",
      "group": "manufacturer",
      "issued": "25 May 2012",
      "effective": null,
      "statedExpiry": null,
      "url": "https://newmor.com/wp-content/uploads/2015/10/Paper-380gsm-Euroclass-B-s2-d0-314369-1.pdf",
      "accessed": "2026-10-15",
      "establishes": "Classification report on Project paper-backed vinyl: B-s2,d0 on dense fibre-cement board, excluding paper-faced plasterboard.",
      "limits": null,
      "status": "current"
    },
    {
      "id": "src-muraspec-dop-cpr0001-2024",
      "issuer": "Muraspec",
      "title": "Declaration of performance CPR0001, version 3",
      "reference": null,
      "type": "declaration_of_performance",
      "group": "manufacturer",
      "issued": "4 September 2024 (signed)",
      "effective": null,
      "statedExpiry": null,
      "url": "https://www.muraspec.com/wp-content/uploads/2024/09/DOP-CPR0001-New-2024-Warrington-s2.pdf",
      "accessed": "2026-10-15",
      "establishes": "Muraspec's 2024 declaration covering several fabric-backed vinyl and textile types, including woven fabric-backed vinyl of 360 to 460 gsm, declared B-s2,d0 on fibre-cement board with Murabond Heavy adhesive. Its listed certificates carry printed expiry dates from December 2026 to March 2027.",
      "limits": "Signed the same day (4 September 2024) as declaration CPR0004 version 1, which declares B-s1,d0 for woven Type I 360 gsm fabric-backed vinyl; this declaration gives B-s2,d0 for woven fabric-backed vinyl of 360 to 460 gsm. Neither says it replaces the other.",
      "status": "current"
    },
    {
      "id": "src-muraspec-dop-cpr0001-2021",
      "issuer": "Muraspec",
      "title": "Declaration of performance CPR0001, January 2021",
      "reference": "CPR0001 (January 2021)",
      "type": "declaration_of_performance",
      "group": "manufacturer",
      "issued": "January 2021",
      "effective": null,
      "statedExpiry": null,
      "url": "https://www.muraspec.com/wp-content/uploads/2023/06/CPR0001UK_Jan_2021.pdf",
      "accessed": "2026-10-15",
      "establishes": "An earlier version of declaration CPR0001. Its product-type table lists no acoustic or foam vinyl.",
      "limits": "Later versions exist (version 3, September 2024).",
      "status": "superseded"
    },
    {
      "id": "src-muraspec-dop-cpr0002-2024",
      "issuer": "Muraspec",
      "title": "Declaration of performance CPR0002, version 3",
      "reference": null,
      "type": "declaration_of_performance",
      "group": "manufacturer",
      "issued": "4 September 2024 (signed)",
      "effective": null,
      "statedExpiry": null,
      "url": "https://www.muraspec.com/wp-content/uploads/2024/09/DOP-CPR0002-New-2024-Warrington-s1.pdf",
      "accessed": "2026-10-15",
      "establishes": "Muraspec's 2024 declaration for paper-backed vinyl and Type II non-woven fabric-backed vinyl, declared B-s1,d0 on fibre-cement board with Murabond Heavy adhesive.",
      "limits": "Whether it has been withdrawn or replaced by the 2025 CPR0003 is not stated.",
      "status": "current"
    },
    {
      "id": "src-muraspec-web-explainer",
      "issuer": "Muraspec",
      "title": "How do fire ratings work? (Muraspec article)",
      "reference": null,
      "type": "webpage",
      "group": "manufacturer",
      "issued": "23 October 2023 (published)",
      "effective": null,
      "statedExpiry": null,
      "url": "https://www.muraspec.com/how-do-fire-ratings-work/",
      "accessed": "2026-10-15",
      "establishes": "Muraspec's general article on fire ratings, which describes its wallcoverings as class B.",
      "limits": "A marketing article, not a declaration or classification; individual product documents differ.",
      "status": "current"
    },
    {
      "id": "src-vescom-f567-efectis-2012",
      "issuer": "Efectis Nederland",
      "title": "Classification report 2012-Efectis-R9438d: Vescom vinyl about 460 g/m² on paper-faced plasterboard",
      "reference": null,
      "type": "classification_report",
      "group": "manufacturer",
      "issued": "November 2012",
      "effective": null,
      "statedExpiry": null,
      "url": "https://documents.vescom-cdn.com/f567/Colour%20Choice%201056%20-%20EN%2013501%2C%20B%20s2%20d0.pdf",
      "accessed": "2026-10-15",
      "establishes": "A 2012 classification of a Vescom 460 g/m² vinyl as B-s2,d0, tested on paper-faced plasterboard with Vescom 2000, under the 2007+A1:2009 edition of EN 13501-1.",
      "limits": "Filed under design names the report does not mention.",
      "status": "current"
    },
    {
      "id": "src-vescom-f18455-dop-13004",
      "issuer": "Vescom",
      "title": "Declaration of performance DOP-CPR-13004: woven animal and synthetic fibre textiles on paper backing",
      "reference": null,
      "type": "declaration_of_performance",
      "group": "manufacturer",
      "issued": "1 January 2024",
      "effective": null,
      "statedExpiry": null,
      "url": "https://documents.vescom-cdn.com/f18455/DOP-CPR-13004%20Animal-Synthetic%20fibre%20mix%20-%20system%203.pdf",
      "accessed": "2026-10-15",
      "establishes": "Vescom's declaration for this textile family, declared B-s1,d0 under System 3 and citing classification report 22965F.",
      "limits": null,
      "status": "current"
    },
    {
      "id": "src-vescom-f1873-general-specs",
      "issuer": "Vescom",
      "title": "General specifications for use: Vescom vinyl, olefin and textile wallcovering (2025)",
      "reference": null,
      "type": "installation_guide",
      "group": "manufacturer",
      "issued": "2025",
      "effective": null,
      "statedExpiry": null,
      "url": "https://documents.vescom-cdn.com/f1873/EN%20-%20Algemeen%20verwerkingsvoorschrift%20-%20Vescom%20vinyl%2C%20olefin%20en%20textiel%20wandbekleding%202025.pdf",
      "accessed": "2026-10-15",
      "establishes": "Vescom's general hanging instructions, which ask for existing wallcoverings and backing papers to be removed.",
      "limits": null,
      "status": "current"
    },
    {
      "id": "src-arte-us-e84-13-03217",
      "issuer": "Commercial Testing Company",
      "title": "ASTM E84 test report 13-03217 (a vinyl substrate submitted by another company), linked from Arte pages as the US Class A certificate",
      "reference": null,
      "type": "test_report",
      "group": "manufacturer",
      "issued": "26 March 2013",
      "effective": null,
      "statedExpiry": null,
      "url": "https://edge.arte-international.com/media/809de728-34ad-436a-8176-dfb1818123c7/Fire-Certificate-Class-A-20oz.pdf",
      "accessed": "2026-10-15",
      "establishes": "A 2013 US tunnel-test report on a different vinyl product, which Arte links as the US fire certificate for its contract vinyls.",
      "limits": "A US test, not a European class, and not a test of Moire Sauvage.",
      "status": "current"
    },
    {
      "id": "src-newmor-bttg-27-06093",
      "issuer": "BTTG",
      "title": "Test report 27/06093/02/23: Premier 20oz non-woven-backed vinyl",
      "reference": null,
      "type": "test_report",
      "group": "manufacturer",
      "issued": "8 March 2023",
      "effective": null,
      "statedExpiry": null,
      "url": "https://newmor.com/wp-content/uploads/2024/06/460gsm-Type-II-nonwoven.pdf",
      "accessed": "2026-10-15",
      "establishes": "A 2023 test report on a Premier 20 oz non-woven-backed vinyl sample (no weight in g/m² is printed; Newmor files it as 460gsm Type II non-woven), giving B, s2, d0.",
      "limits": "Whether this is the same construction as the sample in report 082/BW/22 is not established.",
      "status": "current"
    },
    {
      "id": "src-dreamscape-vinyl-over-vinyl",
      "issuer": "Dreamscape",
      "title": "Can I install wallcovering over existing wallcovering? PVC on PVC (Dreamscape support article)",
      "reference": null,
      "type": "webpage",
      "group": "manufacturer",
      "issued": "7 October 2024 (modified)",
      "effective": null,
      "statedExpiry": null,
      "url": "https://dreamscapewalls.freshdesk.com/support/solutions/articles/12000015609-can-i-install-wallcovering-over-existing-wallcovering-pvc-on-pvc",
      "accessed": "2026-10-15",
      "establishes": "A vinyl wallcovering maker states that installing vinyl over an existing wallcovering voids the product fire rating, and that it has no test data for a double layer.",
      "limits": "One maker speaking about its own products; check each maker’s own guide.",
      "status": "current"
    }
  ],
  "checklists": [
    {
      "title": "Before ordering",
      "intro": "Collect these for each wallcovering and each area it is going into.",
      "items": [
        "The exact product: maker, collection, product reference, colourway or design, and whether it is a stock or digitally printed version.",
        "The construction as supplied: face material, backing, weight and any finish or protective coating.",
        "The requirement for each area: the class set for it, and whether the area is a room, a small room or a circulation space. For building work, the project's fire strategy, designer or building-control body sets the class. For a building in use where the job is not building work, the responsible person sets it, through the fire risk assessment.",
        "The evidence: the current declaration of performance and, where available, the classification report for that product, with their references and dates.",
        "The tested build-up: the substrate, adhesive and any primer or lining named in the classification document, and the field of application it allows.",
        "The proposed build-up on site: the actual wall, any existing finishes, the lining, primer and adhesive to be used, and any coating to be added.",
        "Any difference between the two, with the maker's written position and any test or assessment report relied on. Record who accepted it: for building work, the designer, fire engineer or building-control body; where the job is not building work, the responsible person.",
        "The maker's installation instructions for that product, current at the time of ordering."
      ]
    },
    {
      "title": "At handover",
      "intro": "Keep a record of what was actually installed, so it can be checked later.",
      "items": [
        "A room-by-room or area-by-area schedule of the products installed: reference, colourway and batch number.",
        "Copies of the declaration of performance, classification evidence and installation instructions relied on, with their dates.",
        "The adhesive, primer and lining actually used, with batch numbers where practical, and the substrate each area was hung on.",
        "Any accepted variation from the documented build-up, with the maker's written position, any test or assessment report relied on, and who accepted it.",
        "Photographs of the prepared substrate before hanging, where the project calls for them.",
        "Care and cleaning instructions, including any limit on later coatings or overpainting that would change the build-up.",
        "Spare material from the same batch, labelled, for future repairs."
      ]
    }
  ],
  "faq": [
    {
      "q": "What does B-s1,d0 mean on a wallcovering?",
      "a": "It is a European reaction-to-fire classification under BS EN 13501-1: class B for the main fire behaviour, s1 for the lowest smoke production category and d0 for no flaming droplets or particles in the test. It applies to the product as tested, in the build-up the classification document describes."
    },
    {
      "q": "Is B-s2,d0 good enough for a hotel corridor?",
      "a": "That depends on the requirement set for that corridor. In England, Approved Document B Volume 2 (buildings other than dwellings) gives a minimum of B-s3,d2 for circulation spaces in its Table 6.1, which B-s2,d0 meets, but a project's fire strategy can set a higher requirement, and the product must be installed in the build-up its classification covers. The designer, fire engineer or building-control body decides, or, for a building in use where the job is not building work, the responsible person through the fire risk assessment."
    },
    {
      "q": "A data sheet says only 'Euroclass B'. Is that the same as B-s1,d0?",
      "a": "No. 'Euroclass B' without smoke and droplet subclasses tells you the main class only. Treat the subclasses as unknown and ask the maker for the declaration of performance or classification report, which will state them."
    },
    {
      "q": "Is Class 0 the same as a Euroclass?",
      "a": "No. Class 0 is an old British national classification: a material of limited combustibility throughout, or a BS 476 Part 7 Class 1 material that also meets BS 476 Part 6 fire propagation limits. It was defined in earlier editions of England's Approved Document B and is still printed in the Welsh and Northern Irish guidance. It is not the result of any single test, and there is no automatic conversion between Class 0 and a European class. England's guidance stopped offering national reaction-to-fire classes as an alternative from 2 March 2025, subject to transitional arrangements."
    },
    {
      "q": "Does a fire-rated wallcovering make a wall fire resistant?",
      "a": "No. A wallcovering's class describes its reaction to fire: how it contributes to the early growth of a fire. Fire resistance, expressed in minutes, belongs to walls, floors and doors as building elements, and a wallcovering does not provide it."
    },
    {
      "q": "Can a classified wallcovering be hung over old wallpaper or lining paper?",
      "a": "Only if the maker's documents cover it, or a test or assessment report covers that build-up. The designer, fire engineer or building-control body then has to accept it, or, for a building in use where the job is not building work, the responsible person. Hanging over an existing wallcovering adds an untested layer, and makers' instructions generally ask for old wallcoverings to be removed. Lining paper, a different adhesive or a later coating are also changes to the build-up."
    },
    {
      "q": "Does Mr Wallcover certify the fire rating of what it installs?",
      "a": "No. Classification comes from testing and classification of the product in a stated build-up, and the manufacturer declares the performance. We install the specified product to the maker's instructions and record what was installed. The designer, fire engineer or building-control body accepts the evidence, or, for a building in use where the job is not building work, the responsible person through the fire risk assessment."
    },
    {
      "q": "Do these rules apply in Scotland, Wales and Northern Ireland?",
      "a": "Wales applies the Building Regulations 2010 as amended for Wales, with its own Approved Document B. Scotland and Northern Ireland have their own building regulations, with the Technical Handbooks and Technical Booklet E as guidance. They use the same European classes, but their tables, terms and amendment dates differ, so check the guidance for where the building is."
    }
  ]
}